Evaluation of a Wearable Device to Determine Cardiorespiratory Parameters From Surface Diaphragm Electromyography
The use of wearable devices in clinical routines could reduce healthcare costs and improve the quality of assessment in patients with chronic respiratory diseases. The purpose of this study is to evaluate the capacity of a Shimmer3 wearable device to extract reliable cardiorespiratory parameters fro...
| Autores: | , , , , , |
|---|---|
| Tipo de documento: | artigo |
| Estado: | Versão publicada |
| Data de publicação: | 2019 |
| País: | España |
| Recursos: | Institut d'Investigació i Innovació Parc Taulí (I3PT) |
| Repositório: | r-I3PT. Repositorio Institucional Producción Científica del Institut d'Investigació i Innovació Parc Taulí |
| OAI Identifier: | oai:i3pt.fundanetsuite.com:p5212 |
| Acesso em linha: | https://i3pt.portalinvestigacion.com/publicaciones/5212 |
| Access Level: | Acceso aberto |
| Palavra-chave: | Non-invasive respiratory monitoring cardiorespiratory monitoring surface diaphragm electromyography wearable wireless device chronic respiratory diseases fixed sample entropy |
| Resumo: | The use of wearable devices in clinical routines could reduce healthcare costs and improve the quality of assessment in patients with chronic respiratory diseases. The purpose of this study is to evaluate the capacity of a Shimmer3 wearable device to extract reliable cardiorespiratory parameters from surface diaphragm electromyography (EMGdi). Twenty healthy volunteers underwent an incremental load respiratory test whilst EMGdi was recorded with a Shimmer3 wearable device (EMGdi(W)). Simultaneously, a second EMGdi (EMGdi(L)), inspiratory mouth pressure (Pmouth) and lead-I electrocardiogram (ECG) were recorded via a standard wired laboratory acquisition system. Different cardiorespiratory parameters were extracted from both EMGdi(W) and EMGdi(L) signals: heart rate, respiratory rate, respiratory muscle activity, and mean frequency of EMGdi signals. Alongside these, similar parameters were also extracted from reference signals (Pmouth and ECG). High correlations were found between the data extracted from the EMGdi(W) and the reference signal data: heart rate (R = 0.947), respiratory rate (R = 0.940), respiratory muscle activity (R = 0.877), and mean frequency (R = 0.895). Moreover, similar increments in EMGdi(W) and EMGdi(L) activity were observed when Pmouth was raised, enabling the study of respiratory muscle activation. In summary, the Shimmer3 device is a promising and cost-effective solution for the ambulatory monitoring of respiratory muscle function in chronic respiratory diseases. |
|---|