Comissionamento e dosimetria de TBI utilizando filme radiocrômico, câmara de ionização e detector OSL

The total body irradiation (total body irradiation - TBI) is a special technique of radiotherapy that is part of the bone marrow transplantation conditioning to treat patients with leukemia, lymphoma, autoimmune diseases, multiple myeloma, among others. The measure of this procedure is immunosuppres...

ver descrição completa

Detalhes bibliográficos
Autor: Marins, Priscila de França
Formato: tesis de maestría
Estado:Versión publicada
Fecha de publicación:2019
País:Brasil
Recursos:Universidade Tecnológica Federal do Paraná (UTFPR)
Repositorio:Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
Idioma:portugués
OAI Identifier:oai:repositorio.utfpr.edu.br:1/4241
Acesso em linha:http://repositorio.utfpr.edu.br/jspui/handle/1/4241
Access Level:acceso abierto
Palavra-chave:Radiação - Dosimetria - Testes
Luminescência
Radiografia
Irradiação
Radioterapia
Detectores
Aceleradores lineares
Engenharia biomédica
Radiation dosimetry - Testing
Luminescence
Radiography
Irradiation
Radiotherapy
Detectors
Linear accelerators
Biomedical engineering
CNPQ::ENGENHARIAS::ENGENHARIA BIOMEDICA
Engenharia Biomédica
Descrição
Resumo:The total body irradiation (total body irradiation - TBI) is a special technique of radiotherapy that is part of the bone marrow transplantation conditioning to treat patients with leukemia, lymphoma, autoimmune diseases, multiple myeloma, among others. The measure of this procedure is immunosuppression, bone marrow ablation and destruction of malignant cells, in order to prevent the medication of the transplanted patient. Doses will be considered equivalent or higher for tolerance of risks. This issue is related to dosimetry, a procedure in which it is possible to verify delivery of the dose to the surface or internal organs. Thus, in this study was a methodological unit for the commissioning, consisting of the assessment of the deepdose distribution of the primary problem (PDP) and the off-axis factor for linear accelerator used in the TBI procedures radiocromatic films. After commissioning, the dosimetry parameters were evaluated by means of the internal time dose of an anthropomorphic phantom connected to radiological films and OSO detectors of BeO. As light plates, they were linearly linear, with a capacity of 20 cm depth, radiological films and an ionization chamber were used inside a cubic ghost with water. Positioning the radiochromic film, within a continuous image card phantom at depths of 1.5 to 15 cm for 6 VM and depths of 2.5 to 15 cm for 15 MV, it was possible to calculate the offaxis factor of the central center (dose in the air) The ionization chamber and the radiometric films show the PDPs (differences of up to 5%) In addition, the BeO OSL detectors and the radiometallic films obtained, on average, similar results, to the value In this way, it is concluded that the radiological studies are advantageous for the performance of linear tests and can facilitate and improve the measurement of the indicator dosimeters. BeO detectors can be used for in vivo evaluation during the TBI process.