Rapid method for simultaneous determination of cis-9, trans-11 and trans-10, cis-12 conjugated linoleic acid isomers in milk by gc-fid

Ruminant milk is the lead source of conjugated linoleic acid (CLA) in the human diet, with cis-9, trans-11 CLA being the major among all. Small amounts of trans-10, cis-12 CLA are also found in synthetic supplements. Since both isomers are biologically active with potential health benefits, there is...

Descripción completa

Detalles Bibliográficos
Autores: Brenda Lee Simas Porto, Isaura Daniele Leite Faria, Jéssica Cordeiro Queiroz de Souza, Olívia Brito de Oliveira Moreira, Marco Antonio Sundfeld da Gama, Marcone Augusto Leal de Oliveira
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2023
País:Brasil
Institución:Universidade Federal de Minas Gerais (UFMG)
Repositorio:Repositório Institucional da UFMG
Idioma:inglés
OAI Identifier:oai:repositorio.ufmg.br:1843/78513
Acceso en línea:https://doi.org/10.21577/0100-4042.20230026
http://hdl.handle.net/1843/78513
https://orcid.org/0000-0003-3469-0284
https://orcid.org/0000-0001-5278-9865
https://orcid.org/0000-0002-8073-4236
https://orcid.org/0000-0002-1970-5882
https://orcid.org/0000-0001-6026-9608
Access Level:acceso abierto
Palabra clave:Fast GC
CLA
SLB-IL111
Fatty acids
Milk
Leite
Nanopartículas
Analise cromatografica
Descripción
Sumario:Ruminant milk is the lead source of conjugated linoleic acid (CLA) in the human diet, with cis-9, trans-11 CLA being the major among all. Small amounts of trans-10, cis-12 CLA are also found in synthetic supplements. Since both isomers are biologically active with potential health benefits, there is great interest in quantifying them for quality control routines. An alternative method for the analysis of the baforementioned CLAs by fast gas chromatography (GC) is discussed in the present study. The fatty acid methyl ester mixture obtained by alkaline catalysis was injected into a GC equipped with a fame ionization detector (FID) and fitted with an ionic liquid SLB-IL111 chromatographic column (15 m × 0.10 mm × 0.08 µm). Separation was achieved in less than 5 min using a 168 °C isotherm run. Both CLA isomers were quantified by using of single point standard addition statistical approach. Results were contested to those obtained using the recommended 100 m long CP-Sil88 capillary column and none evidence of significant differences was found within 95% confidence interval. Therefore, the proposed method could be valuable to focused regulatory routines of large numbers of samples with greater analytical frequency.