Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural

358 páginas. Maestría en Diseño.

Detalles Bibliográficos
Autor: Moyo Martínez, Rocío Elena
Tipo de recurso: tesis de maestría
Estado:Versión publicada
Fecha de publicación:2009
País:México
Institución:Universidad Autónoma Metropolitana
Repositorio:Repositorio Institucional Zaloamati
Idioma:español
OAI Identifier:oai:zaloamati.azc.uam.mx:11191/5613
Acceso en línea:http://hdl.handle.net/11191/5613
Access Level:acceso abierto
Palabra clave:HUMANIDADES Y CIENCIAS DE LA CONDUCTA::CIENCIAS DE LAS ARTES Y LAS LETRAS::ARQUITECTURA::DISEÑO ARQUITECTÓNICO
NA2794
Daylighting.
id MX_d1313a13151cb2ecb8895dbf69bb3bfc
oai_identifier_str oai:zaloamati.azc.uam.mx:11191/5613
network_acronym_str MX
network_name_str México
repository_id_str
dc.title.none.fl_str_mv Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural
title Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural
spellingShingle Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural
Moyo Martínez, Rocío Elena
HUMANIDADES Y CIENCIAS DE LA CONDUCTA::CIENCIAS DE LAS ARTES Y LAS LETRAS::ARQUITECTURA::DISEÑO ARQUITECTÓNICO
NA2794
Daylighting.
title_short Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural
title_full Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural
title_fullStr Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural
title_full_unstemmed Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural
title_sort Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación natural
dc.creator.none.fl_str_mv Moyo Martínez, Rocío Elena
author Moyo Martínez, Rocío Elena
author_facet Moyo Martínez, Rocío Elena
author_role author
dc.contributor.none.fl_str_mv GARCIA CHAVEZ, JOSE ROBERTO; 10939
García López, Esperanza
Fuentes Freixanet, Víctor
Aguayo González, Ricardo
Guerrero Vaca, Luis Fernando
GARCIA CHAVEZ, JOSE ROBERTO
dc.subject.none.fl_str_mv HUMANIDADES Y CIENCIAS DE LA CONDUCTA::CIENCIAS DE LAS ARTES Y LAS LETRAS::ARQUITECTURA::DISEÑO ARQUITECTÓNICO
NA2794
Daylighting.
topic HUMANIDADES Y CIENCIAS DE LA CONDUCTA::CIENCIAS DE LAS ARTES Y LAS LETRAS::ARQUITECTURA::DISEÑO ARQUITECTÓNICO
NA2794
Daylighting.
description 358 páginas. Maestría en Diseño.
publishDate 2009
dc.date.none.fl_str_mv 2009-07-06
2017-10-19T17:03:06Z
2017-10-19T17:03:06Z
dc.type.none.fl_str_mv masterThesis
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/11191/5613
url http://hdl.handle.net/11191/5613
dc.language.none.fl_str_mv spa
language spa
dc.rights.none.fl_str_mv Atribución-NoComercial-SinDerivadas
http://creativecommons.org/licenses/by-nc-nd/4.0
openAccess
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Atribución-NoComercial-SinDerivadas
http://creativecommons.org/licenses/by-nc-nd/4.0
openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv pdf
application/pdf
dc.publisher.none.fl_str_mv Universidad Autónoma Metropolitana (México). Unidad Azcapotzalco. Coordinación de Servicios de Información.
publisher.none.fl_str_mv Universidad Autónoma Metropolitana (México). Unidad Azcapotzalco. Coordinación de Servicios de Información.
dc.source.none.fl_str_mv reponame:Repositorio Institucional Zaloamati
instname:Universidad Autónoma Metropolitana
instacron:UAM
instname_str Universidad Autónoma Metropolitana
instacron_str UAM
institution UAM
reponame_str Repositorio Institucional Zaloamati
collection Repositorio Institucional Zaloamati
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1858177095369228288
spelling Sistemas lumínicos de alta eficiencia energética para el aprovechamiento de la iluminación naturalMoyo Martínez, Rocío ElenaHUMANIDADES Y CIENCIAS DE LA CONDUCTA::CIENCIAS DE LAS ARTES Y LAS LETRAS::ARQUITECTURA::DISEÑO ARQUITECTÓNICONA2794Daylighting.358 páginas. Maestría en Diseño.The use of natural illumination has an important impact in the energy use. Most of the buildings consume more than 50% of the energy produced, which provokes pollution. This investigation builds with the analysis and evaluation of the performance of high efficiency luminous systems to reduce the energy construction while proved in comfort from the occupants. The first stage of this investigation consisted of detail diagnostics of the case of the current case study building, sport center building throw monitoring under clear cloudy and semi-cloudy sky conditions. The next stage of this investigation included the construction of the tree dimensional physical model, calibrated, relative to the real case study building. This model was used to implement the high luminous efficiencies systems, the design alternatives investigated were light ducts, and the design variables were: geometry, form, internal and external material and distribution. The results show that the best design alternative was de luminous ducts, in 45 cm in diameter with the special distribution of 3meters, with specula film inside, and external height of 90centimetrers about the roof level and with the ceiling silver painted. The use of this design alternative can reduce about 50 percent the use of electricity for lightin g while maintaining the comfort luminous of the occupants, recommended for the international standards. The application of this luminous high efficient system can give important benefits for energy savings and for improved the environmentEn la arquitectura la utilización de iluminación natural tiene un impacto importante en la problemática energética. La mayoría de los edificios consumen más del 50% de la energía que se produce, creando problemas de contaminación. En este proyecto de investigación se propuso como caso de estudio un sistema de iluminación natural para reducir el consumo energía y dar confort a los usuarios, en un edificio deportivo de la Universidad Autónoma Metropolitana Unidad Azcapotzalco. Se realizó un diagnostico en el edificio existente, a través de mediciones en condiciones de cielo despejado, cielo semi-nublado y cielo nublado. Se construyó un modelo físico tridimensional, calibrado a las condiciones del edificio actual en el cual se evaluaron las alternativas de alta eficiencia energética como son los ductos lumínicos que consistieron en una selección de alternativas de diseño: diámetro, geometría, forma, materiales al interior y distribución espacial. Los resultados del trabajo experimental demostraron que la opción de diseño que mejor funcionamiento presentó fue el ducto lumínico de 45cm de diámetro, con un espaciamiento espacial de 3m, al interior del ducto forrado con material de alta reflectancia, con una altura exterior de 90cm. Comprobándose que la utilización del sistema lumínico de alta eficiencia puede reducir en aproximadamente 50% el uso de iluminación artificial, manteniéndose dentro de los niveles de confort de los estándares internacionales y nacionales. La aplicación de este sistema lumínico de alta eficiencia en otros edificios similares puede tener un beneficio importante, tanto en el ahorro de energía como en el mejoramiento del medio ambiente y el confort lumínico de los ocupantes.Universidad Autónoma Metropolitana (México). Unidad Azcapotzalco. Coordinación de Servicios de Información.GARCIA CHAVEZ, JOSE ROBERTO; 10939García López, EsperanzaFuentes Freixanet, VíctorAguayo González, RicardoGuerrero Vaca, Luis FernandoGARCIA CHAVEZ, JOSE ROBERTO2017-10-19T17:03:06Z2017-10-19T17:03:06Z2009-07-06masterThesisinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesispdfapplication/pdfhttp://hdl.handle.net/11191/5613reponame:Repositorio Institucional Zaloamatiinstname:Universidad Autónoma Metropolitanainstacron:UAMspaAtribución-NoComercial-SinDerivadashttp://creativecommons.org/licenses/by-nc-nd/4.0openAccessinfo:eu-repo/semantics/openAccessoai:zaloamati.azc.uam.mx:11191/56132024-08-28T04:06:40Z
score 14,964252