¿Es posible incrementar la sensibilidad diagnóstica de una radiografía?

Introduction. The qualities that digital x-rays possess, and which analog x-ray lack, are unquestionable. In an effort to obtain analogic x-rays that have the same qualities, wehave implemented a technique that uses the photographic process and digital processing of images. Using them individually o...

Descripción completa

Detalles Bibliográficos
Autor: ALBERTO JARAMILLO NUÑEZ
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2013
País:México
Institución:Instituto Nacional de Astrofísica, Óptica y Electrónica
Repositorio:Repositorio Institucional del INAOE
Idioma:español
OAI Identifier:oai:inaoe.repositorioinstitucional.mx:1009/2126
Acceso en línea:http://inaoe.repositorioinstitucional.mx/jspui/handle/1009/2126
Access Level:acceso abierto
Palabra clave:info:eu-repo/classification/Radiografías planas/Flat x-rays
info:eu-repo/classification/Fotografía/Photography
info:eu-repo/classification/Procesado digital de imágenes/Digital image processing
info:eu-repo/classification/cti/1
info:eu-repo/classification/cti/22
info:eu-repo/classification/cti/2209
Descripción
Sumario:Introduction. The qualities that digital x-rays possess, and which analog x-ray lack, are unquestionable. In an effort to obtain analogic x-rays that have the same qualities, wehave implemented a technique that uses the photographic process and digital processing of images. Using them individually or simultaneously, depending on the problem, we have found that sensitivity can be increased to the point where it is possible to view details that would be difficult to see otherwise. At times high resolution is also needed, and thus far we have achieved 10 microns; however, that value can be improved in the near future usingh igher resolution detectors. We show theresults of applying the technique in four cases. Material and methods. The x-rays were photographed using a CCD (charge coupled device) camera and a fixed focal distance lens. Controlling the diameter of the diaphragm, we obtained contrasted images even when the x-ray is dark or bright. Changing the distance between the camera and the x-ray we controlled the size of the photographed area. The pixel size of the CCD camera is 3 microns and the size of the digitalized images is 3000 × 2200 pixels. The maximum resolution obtained is 10 microns for an x-ray area of 30 × 25 mm. To show some of the advantages of the technique, four cases were analyzed: rheumatoid arthritis, osteopenia, breast cancer, and calcifications.