Multi-layer health-aware economic predictive control of a pasteurization pilot plant
This paper proposes two different health-aware economic predictive control strategies that aim at minimizing the damage of components in a pasteurization plant. The damage is assessed with a rainflow-counting algorithm that allows estimating the components’ fatigue. By using the results obtained fro...
| Authors: | , , |
|---|---|
| Format: | article |
| Status: | Published version |
| Publication Date: | 2018 |
| Country: | España |
| Institution: | Consejo Superior de Investigaciones Científicas (CSIC) |
| Repository: | DIGITAL.CSIC. Repositorio Institucional del CSIC |
| OAI Identifier: | oai:digital.csic.es:10261/179603 |
| Online Access: | http://hdl.handle.net/10261/179603 |
| Access Level: | Open access |
| Keyword: | Model predictive control Two-layers control scheme Fatigue Economic optimization Health-aware controller |
| id |
ES_fd9af4c8a66a55be082b4f3c408de7ef |
|---|---|
| oai_identifier_str |
oai:digital.csic.es:10261/179603 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Multi-layer health-aware economic predictive control of a pasteurization pilot plantKarimi Pour, FatemehPuig, VicençOcampo-Martínez, CarlosModel predictive controlTwo-layers control schemeFatigueEconomic optimizationHealth-aware controllerThis paper proposes two different health-aware economic predictive control strategies that aim at minimizing the damage of components in a pasteurization plant. The damage is assessed with a rainflow-counting algorithm that allows estimating the components’ fatigue. By using the results obtained from this algorithm, a simplified model that characterizes the health of the system is developed and integrated into the predictive controller. The overall control objective is modified by adding an extra criterion that takes into account the accumulated damage. The first strategy is a single-layer predictive controller with an integral action to eliminate the steady-state error that appears when adding the extra criterion. In order to achieve the best minimal accumulated damage and operational costs, the single-layer approach is improved with a multi-layer control scheme, where the solution of the dynamic optimization problem is obtained from the model in two different time scales. Finally, to achieve the advisable trade-off between minimal accumulated damage and operational costs, both control strategies are compared in simulation over a utility-scale pasteurization plant.This work has been partially funded by the Spanish Government (MINECO) through the project DEOCS (DPI2016-76493-C3-3-R), and by MINECO and FEDER through the project HARCRICS (DPI2014-58104-R).Peer reviewedWalter de GruyterMinisterio de Economía y Competitividad (España)European CommissionConsejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]201920192018info:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_6501Publisher's versioninfo:eu-repo/semantics/publishedVersionhttp://hdl.handle.net/10261/179603reponame:DIGITAL.CSIC. Repositorio Institucional del CSICinstname:Consejo Superior de Investigaciones Científicas (CSIC)Inglés#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2016-76493-C3-3-Rinfo:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2014-58104-RSíinfo:eu-repo/semantics/openAccessoai:digital.csic.es:10261/1796032026-05-22T06:33:51Z |
| dc.title.none.fl_str_mv |
Multi-layer health-aware economic predictive control of a pasteurization pilot plant |
| title |
Multi-layer health-aware economic predictive control of a pasteurization pilot plant |
| spellingShingle |
Multi-layer health-aware economic predictive control of a pasteurization pilot plant Karimi Pour, Fatemeh Model predictive control Two-layers control scheme Fatigue Economic optimization Health-aware controller |
| title_short |
Multi-layer health-aware economic predictive control of a pasteurization pilot plant |
| title_full |
Multi-layer health-aware economic predictive control of a pasteurization pilot plant |
| title_fullStr |
Multi-layer health-aware economic predictive control of a pasteurization pilot plant |
| title_full_unstemmed |
Multi-layer health-aware economic predictive control of a pasteurization pilot plant |
| title_sort |
Multi-layer health-aware economic predictive control of a pasteurization pilot plant |
| dc.creator.none.fl_str_mv |
Karimi Pour, Fatemeh Puig, Vicenç Ocampo-Martínez, Carlos |
| author |
Karimi Pour, Fatemeh |
| author_facet |
Karimi Pour, Fatemeh Puig, Vicenç Ocampo-Martínez, Carlos |
| author_role |
author |
| author2 |
Puig, Vicenç Ocampo-Martínez, Carlos |
| author2_role |
author author |
| dc.contributor.none.fl_str_mv |
Ministerio de Economía y Competitividad (España) European Commission Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72] |
| dc.subject.none.fl_str_mv |
Model predictive control Two-layers control scheme Fatigue Economic optimization Health-aware controller |
| topic |
Model predictive control Two-layers control scheme Fatigue Economic optimization Health-aware controller |
| description |
This paper proposes two different health-aware economic predictive control strategies that aim at minimizing the damage of components in a pasteurization plant. The damage is assessed with a rainflow-counting algorithm that allows estimating the components’ fatigue. By using the results obtained from this algorithm, a simplified model that characterizes the health of the system is developed and integrated into the predictive controller. The overall control objective is modified by adding an extra criterion that takes into account the accumulated damage. The first strategy is a single-layer predictive controller with an integral action to eliminate the steady-state error that appears when adding the extra criterion. In order to achieve the best minimal accumulated damage and operational costs, the single-layer approach is improved with a multi-layer control scheme, where the solution of the dynamic optimization problem is obtained from the model in two different time scales. Finally, to achieve the advisable trade-off between minimal accumulated damage and operational costs, both control strategies are compared in simulation over a utility-scale pasteurization plant. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018 2019 2019 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article http://purl.org/coar/resource_type/c_6501 Publisher's version info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10261/179603 |
| url |
http://hdl.handle.net/10261/179603 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
#PLACEHOLDER_PARENT_METADATA_VALUE# #PLACEHOLDER_PARENT_METADATA_VALUE# info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2016-76493-C3-3-R info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2014-58104-R Sí |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
Walter de Gruyter |
| publisher.none.fl_str_mv |
Walter de Gruyter |
| dc.source.none.fl_str_mv |
reponame:DIGITAL.CSIC. Repositorio Institucional del CSIC instname:Consejo Superior de Investigaciones Científicas (CSIC) |
| instname_str |
Consejo Superior de Investigaciones Científicas (CSIC) |
| reponame_str |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| collection |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869425581505904640 |
| score |
15,81155 |