Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing

This article aimed to assess the marginal fit of methacrylate-oligomer-phosphine-oxide curable-resin provisional-fixed dental prostheses made by digital-light-processing (DLP) three-dimensional (3D) printing. A stainless-steel master model with two abutments was scanned, and five three-unit provisio...

Descripción completa

Detalles Bibliográficos
Autores: Molinero Mourelle, Pedro, Gómez Polo, Miguel Ángel, Gómez Polo, Cristina, Ortega, Rocio, Río Highsmith, Jaime Del, Celemín Viñuela, María Del Pilar Alicia
Tipo de recurso: artículo
Fecha de publicación:2020
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/8341
Acceso en línea:https://hdl.handle.net/20.500.14352/8341
Access Level:acceso abierto
Palabra clave:Dental prosthesis
Provisional restoration
CAD/CAM
Marginal fit
3D printing
Odontología (Odontología)
Prótesis dental
3213.13 Ortodoncia-Estomatología
3314.02 Prótesis
id ES_fd8050504f4e5cd42de95ce96ca54dda
oai_identifier_str oai:docta.ucm.es:20.500.14352/8341
network_acronym_str ES
network_name_str España
repository_id_str
spelling Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light ProcessingMolinero Mourelle, PedroGómez Polo, Miguel ÁngelGómez Polo, CristinaOrtega, RocioRío Highsmith, Jaime DelCelemín Viñuela, María Del Pilar AliciaDental prosthesisProvisional restorationCAD/CAMMarginal fit3D printingOdontología (Odontología)Prótesis dental3213.13 Ortodoncia-Estomatología3314.02 PrótesisThis article aimed to assess the marginal fit of methacrylate-oligomer-phosphine-oxide curable-resin provisional-fixed dental prostheses made by digital-light-processing (DLP) three-dimensional (3D) printing. A stainless-steel master model with two abutments was scanned, and five three-unit provisional bridges were designed and printed in VITA shade A3.5 curable resin in 50 µm-thick layers. The marginal fit of each abutment was measured at six points using a profile projector. A descriptive data analysis of the fit measurements was performed by descriptive and explorative processes with the SPSS software. The curable-resin provisional restorations made by DLP 3D printing reached values of 46.37 µm (SD: 29.58 µm), which were considered clinically acceptable, with values similar to polyethylene-methacrylate and polyether-ether-ketone provisional restorations.MDPIUniversidad Complutense de Madrid20202020-09-0720202020-09-07journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/8341reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Atribución 3.0 Españahttps://creativecommons.org/licenses/by/3.0/es/info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/83412026-06-02T12:44:21Z
dc.title.none.fl_str_mv Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
title Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
spellingShingle Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
Molinero Mourelle, Pedro
Dental prosthesis
Provisional restoration
CAD/CAM
Marginal fit
3D printing
Odontología (Odontología)
Prótesis dental
3213.13 Ortodoncia-Estomatología
3314.02 Prótesis
title_short Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
title_full Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
title_fullStr Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
title_full_unstemmed Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
title_sort Preliminary Study on the Assessment of the Marginal Fit of Three-Dimensional Methacrylate Oligomer Phosphine Oxide Provisional Fixed Dental Prostheses Made by Digital Light Processing
dc.creator.none.fl_str_mv Molinero Mourelle, Pedro
Gómez Polo, Miguel Ángel
Gómez Polo, Cristina
Ortega, Rocio
Río Highsmith, Jaime Del
Celemín Viñuela, María Del Pilar Alicia
author Molinero Mourelle, Pedro
author_facet Molinero Mourelle, Pedro
Gómez Polo, Miguel Ángel
Gómez Polo, Cristina
Ortega, Rocio
Río Highsmith, Jaime Del
Celemín Viñuela, María Del Pilar Alicia
author_role author
author2 Gómez Polo, Miguel Ángel
Gómez Polo, Cristina
Ortega, Rocio
Río Highsmith, Jaime Del
Celemín Viñuela, María Del Pilar Alicia
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidad Complutense de Madrid
dc.subject.none.fl_str_mv Dental prosthesis
Provisional restoration
CAD/CAM
Marginal fit
3D printing
Odontología (Odontología)
Prótesis dental
3213.13 Ortodoncia-Estomatología
3314.02 Prótesis
topic Dental prosthesis
Provisional restoration
CAD/CAM
Marginal fit
3D printing
Odontología (Odontología)
Prótesis dental
3213.13 Ortodoncia-Estomatología
3314.02 Prótesis
description This article aimed to assess the marginal fit of methacrylate-oligomer-phosphine-oxide curable-resin provisional-fixed dental prostheses made by digital-light-processing (DLP) three-dimensional (3D) printing. A stainless-steel master model with two abutments was scanned, and five three-unit provisional bridges were designed and printed in VITA shade A3.5 curable resin in 50 µm-thick layers. The marginal fit of each abutment was measured at six points using a profile projector. A descriptive data analysis of the fit measurements was performed by descriptive and explorative processes with the SPSS software. The curable-resin provisional restorations made by DLP 3D printing reached values of 46.37 µm (SD: 29.58 µm), which were considered clinically acceptable, with values similar to polyethylene-methacrylate and polyether-ether-ketone provisional restorations.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-09-07
2020
2020-09-07
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/20.500.14352/8341
url https://hdl.handle.net/20.500.14352/8341
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 3.0 España
https://creativecommons.org/licenses/by/3.0/es/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 3.0 España
https://creativecommons.org/licenses/by/3.0/es/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Docta Complutense
instname:Universidad Complutense de Madrid (UCM)
instname_str Universidad Complutense de Madrid (UCM)
reponame_str Docta Complutense
collection Docta Complutense
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869425545925623808
score 15.300724