Multicentre study of magnet ingestion in Spanish paediatric emergency departments.

INTRODUCTION: The ingestion of magnetic objects can cause complications in children, and there are no epidemiological or clinical data on the subject in Spain. OBJECTIVES: To determine the incidence, epidemiological characteristics and management of magnet ingestion in paediatric emergency departmen...

Descripción completa

Detalles Bibliográficos
Autores: Arbeloa Miranda, Amaia, Samson, Frédéric, Andina Martínez, David, Ruiz Domínguez, Juan Antonio, Trenchs Sáinz de la Maza, Victoria, Azcunaga Santibañez, Beatriz, Cadenas Benítez, María Noelia, Díaz Simal, Laura, Lobato Salinas, Zulema, Gilabert Iriondo, Nuria, Olivas López de Soria, Cristina, Landa Maya, José Julián, Pérez Sáez, María Amalia, Romero-Hombrebueno Domínguez, Nieves, Casquero Cossío, Alejandro, Grupo Ingesta Imanes RiSEUP SPERG
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universidad del País Vasco
Repositorio:Addi. Archivo Digital para la Docencia y la Investigación
OAI Identifier:oai:addi.ehu.eus:10810/58357
Acceso en línea:http://hdl.handle.net/10810/58357
Access Level:acceso abierto
Palabra clave:foreign body ingestion
imanes
ingestion
magnetic objects
paediatric emergencies
Descripción
Sumario:INTRODUCTION: The ingestion of magnetic objects can cause complications in children, and there are no epidemiological or clinical data on the subject in Spain. OBJECTIVES: To determine the incidence, epidemiological characteristics and management of magnet ingestion in paediatric emergency departments in Spain. MATERIAL AND METHODS: Prospective observational multicentre study conducted over a 3-year period. The study universe consisted of patients aged less than 14 years. RESULTS: The incidence was 4.8 cases per 100 000 emergency care episodes. Of the 72 patients included (mean age, 7.2 years), 54% were male. Seven percent had neuropsychiatric disorders. Sixty-one percent of the magnets were spherical and 69% came from toys. The size was variable, most frequently between 5 and 10 mm (50%), and ranging from 3 to 30 mm. Eighty-six percent of patients were asymptomatic. The most frequent symptom was abdominal pain. Eighty-three percent of the patients sought medical care within 6 h of ingestion and 92% within 24 h. Thirty-one percent of the cases were of multiple ingestion. Endoscopy was required for extraction in 15% of cases, a proportion that rose to 36% in the group of cases of multiple ingestion. None of the patients required surgery. We did not observe any gastrointestinal complications of magnet ingestion. CONCLUSIONS: The ingestion of multiple magnets is less frequent than single magnet ingestion, and we did not observe any complications despite the lower frequency of procedures compared to other studies.