Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants

Implantoplasty (IP) is used in dental implants with peri-implantitis and aims to remove threads and polish rough surfaces in order to prevent bacterial colonization. As a result of this procedure, implant strength might be compromised. We tested 20 tapered screw-shaped Ti6Al4V dental implants with a...

ver descrição completa

Detalhes bibliográficos
Autores: Camps Font, Octavi, Toledano Serrabona, Jorge, Juiz Camps, Ana Maria, Gil, Javier, Sánchez Garcés, Ma. Ángeles, Barbosa de Figueiredo, Rui Pedro, Gay Escoda, Cosme, Valmaseda Castellón, Eduardo
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2023
País:España
Recursos:Universidad de Barcelona
Repositorio:Dipòsit Digital de la UB
OAI Identifier:oai:diposit.ub.edu:2445/195451
Acesso em linha:https://hdl.handle.net/2445/195451
Access Level:acceso abierto
Palavra-chave:Implants dentals
Corrosió i anticorrosius
Fatiga de materials
Dental implants
Corrosion and anti-corrosives
Fatigue of materials
id ES_fa7588c934bdde2fc76cd0da95a100aa
oai_identifier_str oai:diposit.ub.edu:2445/195451
network_acronym_str ES
network_name_str España
repository_id_str
spelling Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implantsCamps Font, OctaviToledano Serrabona, JorgeJuiz Camps, Ana MariaGil, JavierSánchez Garcés, Ma. ÁngelesBarbosa de Figueiredo, Rui PedroGay Escoda, CosmeValmaseda Castellón, EduardoImplants dentalsCorrosió i anticorrosiusFatiga de materialsDental implantsCorrosion and anti-corrosivesFatigue of materialsImplantoplasty (IP) is used in dental implants with peri-implantitis and aims to remove threads and polish rough surfaces in order to prevent bacterial colonization. As a result of this procedure, implant strength might be compromised. We tested 20 tapered screw-shaped Ti6Al4V dental implants with a simulated bone loss of 50%. Ten implants underwent IP and 10 served as controls. Surface topography (Sa, Sz, Ssk, and Sdr) was analyzed with a confocal optical microscope. Subsequently, a minimum of four series of cyclic loads were applied with a servo-hydraulic mechanical testing machine (5 × 106 cycles at 15 Hz, between a maximal nominal value-starting at 529 N in the IP group and 735 N in the control group-and 10% of that force). We recorded the number of cycles until failure and the type of failure. Implant failure was analyzed by visual inspection and scanning electron microscopy. Open circuit potential and potenctiodynamic tests were carried out with high precision potentiostat using Hank's solution at 37 °C to evaluate the effect of the implantoplasty on the corrosion resistance. Implantoplasty significantly reduced the surface topography values (median) and interquartile range (IQR); Sa from 1.76 (IQR = 0.11) to 0.49 (IQR = 0.16), Sz from 20.98 (IQR = 8.14) to 8.19 (IQR = 4.16), Ssk from 0.01 (IQR = 0.34) to −0.74 (IQR = 0.53) and Sdr from 18.20 (IQR = 2.26) to 2.67 (IQR = 0.87). The fatigue limits of the control and implantoplasty groups were 551 N and 529 N, respectively. The scanning electron micrographs showed fatigue striations indicating fatigue failure. Besides, the fractographic analysis revealed a typical brittle intergranular fracture mechanism. The infinite life range of the dental implants evaluated was largely above the threshold of usual chewing forces. Implantoplasty seems to render a fairly smooth surface and has a limited impact on fatigue resistance. In addition, implantoplasty produces a decrease in the corrosion resistance of the implant. Corrosion current density from 0.019 μA/cm2 for as-received to 0.069 μA/cm2 in the interface smooth-roughened dental implant. These places between the machining and the rough area of the implant are the most susceptible, with the appearance of pitting.MDPI2023info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/195451Articles publicats en revistes (Odontoestomatologia)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: https://doi.org/10.3390/jfb14020061Journal of Functional Biomaterials, 2023, vol. 14, num. 2https://doi.org/10.3390/jfb14020061cc-by (c) Camps Font, Octavi et al., 2023https://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/1954512026-05-27T06:46:51Z
dc.title.none.fl_str_mv Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants
title Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants
spellingShingle Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants
Camps Font, Octavi
Implants dentals
Corrosió i anticorrosius
Fatiga de materials
Dental implants
Corrosion and anti-corrosives
Fatigue of materials
title_short Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants
title_full Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants
title_fullStr Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants
title_full_unstemmed Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants
title_sort Effect of implantoplasty on roughness, fatigue and corrosion behavior of narrow diameter dental implants
dc.creator.none.fl_str_mv Camps Font, Octavi
Toledano Serrabona, Jorge
Juiz Camps, Ana Maria
Gil, Javier
Sánchez Garcés, Ma. Ángeles
Barbosa de Figueiredo, Rui Pedro
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
author Camps Font, Octavi
author_facet Camps Font, Octavi
Toledano Serrabona, Jorge
Juiz Camps, Ana Maria
Gil, Javier
Sánchez Garcés, Ma. Ángeles
Barbosa de Figueiredo, Rui Pedro
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
author_role author
author2 Toledano Serrabona, Jorge
Juiz Camps, Ana Maria
Gil, Javier
Sánchez Garcés, Ma. Ángeles
Barbosa de Figueiredo, Rui Pedro
Gay Escoda, Cosme
Valmaseda Castellón, Eduardo
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Implants dentals
Corrosió i anticorrosius
Fatiga de materials
Dental implants
Corrosion and anti-corrosives
Fatigue of materials
topic Implants dentals
Corrosió i anticorrosius
Fatiga de materials
Dental implants
Corrosion and anti-corrosives
Fatigue of materials
description Implantoplasty (IP) is used in dental implants with peri-implantitis and aims to remove threads and polish rough surfaces in order to prevent bacterial colonization. As a result of this procedure, implant strength might be compromised. We tested 20 tapered screw-shaped Ti6Al4V dental implants with a simulated bone loss of 50%. Ten implants underwent IP and 10 served as controls. Surface topography (Sa, Sz, Ssk, and Sdr) was analyzed with a confocal optical microscope. Subsequently, a minimum of four series of cyclic loads were applied with a servo-hydraulic mechanical testing machine (5 × 106 cycles at 15 Hz, between a maximal nominal value-starting at 529 N in the IP group and 735 N in the control group-and 10% of that force). We recorded the number of cycles until failure and the type of failure. Implant failure was analyzed by visual inspection and scanning electron microscopy. Open circuit potential and potenctiodynamic tests were carried out with high precision potentiostat using Hank's solution at 37 °C to evaluate the effect of the implantoplasty on the corrosion resistance. Implantoplasty significantly reduced the surface topography values (median) and interquartile range (IQR); Sa from 1.76 (IQR = 0.11) to 0.49 (IQR = 0.16), Sz from 20.98 (IQR = 8.14) to 8.19 (IQR = 4.16), Ssk from 0.01 (IQR = 0.34) to −0.74 (IQR = 0.53) and Sdr from 18.20 (IQR = 2.26) to 2.67 (IQR = 0.87). The fatigue limits of the control and implantoplasty groups were 551 N and 529 N, respectively. The scanning electron micrographs showed fatigue striations indicating fatigue failure. Besides, the fractographic analysis revealed a typical brittle intergranular fracture mechanism. The infinite life range of the dental implants evaluated was largely above the threshold of usual chewing forces. Implantoplasty seems to render a fairly smooth surface and has a limited impact on fatigue resistance. In addition, implantoplasty produces a decrease in the corrosion resistance of the implant. Corrosion current density from 0.019 μA/cm2 for as-received to 0.069 μA/cm2 in the interface smooth-roughened dental implant. These places between the machining and the rough area of the implant are the most susceptible, with the appearance of pitting.
publishDate 2023
dc.date.none.fl_str_mv 2023
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/2445/195451
url https://hdl.handle.net/2445/195451
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Reproducció del document publicat a: https://doi.org/10.3390/jfb14020061
Journal of Functional Biomaterials, 2023, vol. 14, num. 2
https://doi.org/10.3390/jfb14020061
dc.rights.none.fl_str_mv cc-by (c) Camps Font, Octavi et al., 2023
https://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv cc-by (c) Camps Font, Octavi et al., 2023
https://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv Articles publicats en revistes (Odontoestomatologia)
reponame:Dipòsit Digital de la UB
instname:Universidad de Barcelona
instname_str Universidad de Barcelona
reponame_str Dipòsit Digital de la UB
collection Dipòsit Digital de la UB
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869425213071949824
score 15,300724