Evaluation of Passive Strategies for Achieving Hygrothermal Comfort in Social Housing Buildings in the Dominican Republic

[EN] In a building, the thermal satisfaction an individual may experience generally influences their health, well-being, productivity, and energy consumption. The concept of thermal comfort and its importance in buildings has been known for some time. However, in the Dominican Republic, discussing t...

ver descrição completa

Detalhes bibliográficos
Autores: Acosta-Medina, Dayana, Quintana-Gallardo, Alberto|||0000-0002-8911-595X, Guillén Guillamón, Ignacio Enrique|||0000-0001-5546-1486, Mendiguchia-Fontes, Fernando Aitor
Formato: artículo
Fecha de publicación:2025
País:España
Recursos:Universitat Politècnica de València (UPV)
Repositorio:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia
Idioma:inglés
OAI Identifier:oai:dnet:riunet______::def5dc54e7887d3b680d19c69bf87486
Acesso em linha:https://riunet.upv.es/handle/10251/235351
Access Level:acceso abierto
Palavra-chave:Thermal comfort
Passive strategies
Thermal simulation
Social housing
01.- Erradicar la pobreza en todas sus formas en todo el mundo
03.- Garantizar una vida saludable y promover el bienestar para todos y todas en todas las edades
10.- Reducir las desigualdades entre países y dentro de ellos
Descrição
Resumo:[EN] In a building, the thermal satisfaction an individual may experience generally influences their health, well-being, productivity, and energy consumption. The concept of thermal comfort and its importance in buildings has been known for some time. However, in the Dominican Republic, discussing thermal comfort in social housing is a challenge since there have not been many studies applied to this context, especially to social housing. For this reason, this research analyzed the thermal behavior of a typical social housing building through energy simulation, aiming to highlight the importance of passive strategies to improve comfort in a warm and humid climate without using air conditioning. The simulation was conducted using OpenStudio v3.9, which utilizes the EnergyPlus v9.4 calculation engine. Three case studies were analyzed, implementing passive measures and seeking to achieve temperatures within the comfort ranges of the housing prototype. The results show that combining different passive strategies for warm-humid climates significantly reduces temperature, achieving reductions of up to 2.8 degrees C in the colder period and up to 3.2 degrees C in the warmer period.