Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence

Background and purpose: Urinary incontinence is one of the most serious complications of prostate cancer treatment. The objective of this study was to assess efficacy and safety of Adjustable Transobturator Male System (ATOMS) compared to Adjustable Continence Therapy (proACT) for male stress urinar...

Descripción completa

Detalles Bibliográficos
Autores: Angulo Cuesta, Javier, Schönburg, Sandra, Giammò, Alessandro, Abellán, Francisco J., Arance Gil, José Ignacio, Lora, David
Tipo de recurso: artículo
Fecha de publicación:2019
País:España
Institución:Universidad Europea (UEM)
Repositorio:ABACUS. Repositorio de Producción Científica
Idioma:inglés
OAI Identifier:oai:abacus.universidadeuropea.com:11268/10291
Acceso en línea:http://hdl.handle.net/11268/10291
Access Level:acceso abierto
Palabra clave:Neoplasias de la próstata
Incontinencia urinaria
Cáncer
Urología
Tecnología médica
id ES_f2faedd9103bee6dd3cb581d5b1241bd
oai_identifier_str oai:abacus.universidadeuropea.com:11268/10291
network_acronym_str ES
network_name_str España
repository_id_str
spelling Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinenceAngulo Cuesta, JavierSchönburg, SandraGiammò, AlessandroAbellán, Francisco J.Arance Gil, José IgnacioLora, DavidNeoplasias de la próstataIncontinencia urinariaCáncerUrologíaTecnología médicaBackground and purpose: Urinary incontinence is one of the most serious complications of prostate cancer treatment. The objective of this study was to assess efficacy and safety of Adjustable Transobturator Male System (ATOMS) compared to Adjustable Continence Therapy (proACT) for male stress urinary incotinence according to literature findings. Material and methods: A systematic review and meta-analysis on adjustable devices ATOMS and ProACT is presented. Studies on female or neurogenic incontinence were excluded. Differences between ATOMS and proACT in primary objective: dryness status (no-pad or one safety pad/day) after initial device adjustment, and in secondary objectives: improvement, satisfaction, complications and device durability, were estimated using random-effect model. Statistical heterogeneity among studies included in the meta-analysis was assessed using tau2, Higgins´s I2 statistics and Cochran´s Q test. Results: Combined data of 41 observational studies with 3059 patients showed higher dryness (68 vs. 55%; p = .01) and improvement (91 vs. 80%; p = .007) rate for ATOMS than ProACT. Mean pad-count (-4 vs. -2.5 pads/day; p = .005) and pad-test decrease (-425.7 vs. -211.4 cc; p < .0001) were also significantly lower. Satisfaction was higher for ATOMS (87 vs. 56%; p = .002) and explant rate was higher for proACT (5 vs. 24%; p < .0001). Complication rate for ProACT was also higher, but not statistically significant (17 vs. 26%; p = .07). Mean follow-up was 25.7 months, lower for ATOMS than ProACT (20.8 vs. 30.6 months; p = .02). The rate of working devices favoured ATOMS at 1-year (92 vs. 76; p < .0001), 2-years (85 vs. 61%; p = .0008) and 3-years (81 vs. 58%; p = .0001). Significant heterogeneity was evidenced, due to variable incontinence severity baseline, difficulties for a common reporting of complications, different number of adjustments and time of follow-up and absence of randomized studies. Conclusions: Despite the limitations that studies available are exclusively descriptive and the follow-up is limited, literature findings confirm ATOMS is more efficacious, with higher patient satisfaction and better durability than ProACT to treat male stress incontinence.20212021-08-0520192019-01-0120192019-01-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/11268/10291reponame:ABACUS. Repositorio de Producción Científicainstname:Universidad Europea (UEM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Attribution-NonCommercial-NoDerivatives 4.0 Internacionalhttp://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:abacus.universidadeuropea.com:11268/102912026-06-11T12:41:27Z
dc.title.none.fl_str_mv Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
title Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
spellingShingle Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
Angulo Cuesta, Javier
Neoplasias de la próstata
Incontinencia urinaria
Cáncer
Urología
Tecnología médica
title_short Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
title_full Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
title_fullStr Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
title_full_unstemmed Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
title_sort Systematic review and meta-analysis comparing Adjustable Transobturator Male System (ATOMS) and Adjustable Continence Therapy (ProACT) for male stress incontinence
dc.creator.none.fl_str_mv Angulo Cuesta, Javier
Schönburg, Sandra
Giammò, Alessandro
Abellán, Francisco J.
Arance Gil, José Ignacio
Lora, David
author Angulo Cuesta, Javier
author_facet Angulo Cuesta, Javier
Schönburg, Sandra
Giammò, Alessandro
Abellán, Francisco J.
Arance Gil, José Ignacio
Lora, David
author_role author
author2 Schönburg, Sandra
Giammò, Alessandro
Abellán, Francisco J.
Arance Gil, José Ignacio
Lora, David
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv
dc.subject.none.fl_str_mv Neoplasias de la próstata
Incontinencia urinaria
Cáncer
Urología
Tecnología médica
topic Neoplasias de la próstata
Incontinencia urinaria
Cáncer
Urología
Tecnología médica
description Background and purpose: Urinary incontinence is one of the most serious complications of prostate cancer treatment. The objective of this study was to assess efficacy and safety of Adjustable Transobturator Male System (ATOMS) compared to Adjustable Continence Therapy (proACT) for male stress urinary incotinence according to literature findings. Material and methods: A systematic review and meta-analysis on adjustable devices ATOMS and ProACT is presented. Studies on female or neurogenic incontinence were excluded. Differences between ATOMS and proACT in primary objective: dryness status (no-pad or one safety pad/day) after initial device adjustment, and in secondary objectives: improvement, satisfaction, complications and device durability, were estimated using random-effect model. Statistical heterogeneity among studies included in the meta-analysis was assessed using tau2, Higgins´s I2 statistics and Cochran´s Q test. Results: Combined data of 41 observational studies with 3059 patients showed higher dryness (68 vs. 55%; p = .01) and improvement (91 vs. 80%; p = .007) rate for ATOMS than ProACT. Mean pad-count (-4 vs. -2.5 pads/day; p = .005) and pad-test decrease (-425.7 vs. -211.4 cc; p < .0001) were also significantly lower. Satisfaction was higher for ATOMS (87 vs. 56%; p = .002) and explant rate was higher for proACT (5 vs. 24%; p < .0001). Complication rate for ProACT was also higher, but not statistically significant (17 vs. 26%; p = .07). Mean follow-up was 25.7 months, lower for ATOMS than ProACT (20.8 vs. 30.6 months; p = .02). The rate of working devices favoured ATOMS at 1-year (92 vs. 76; p < .0001), 2-years (85 vs. 61%; p = .0008) and 3-years (81 vs. 58%; p = .0001). Significant heterogeneity was evidenced, due to variable incontinence severity baseline, difficulties for a common reporting of complications, different number of adjustments and time of follow-up and absence of randomized studies. Conclusions: Despite the limitations that studies available are exclusively descriptive and the follow-up is limited, literature findings confirm ATOMS is more efficacious, with higher patient satisfaction and better durability than ProACT to treat male stress incontinence.
publishDate 2019
dc.date.none.fl_str_mv 2019
2019-01-01
2019
2019-01-01
2021
2021-08-05
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv http://hdl.handle.net/11268/10291
url http://hdl.handle.net/11268/10291
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
http://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
http://creativecommons.org/licenses/by-nc-nd/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:ABACUS. Repositorio de Producción Científica
instname:Universidad Europea (UEM)
instname_str Universidad Europea (UEM)
reponame_str ABACUS. Repositorio de Producción Científica
collection ABACUS. Repositorio de Producción Científica
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869424333314588672
score 15.301629