Influence of the grip width on the reliability and magnitude of different velocity variables during the bench press exercise
[EN] This study aimed to compare the within-session reliability and magnitude of velocity variables recorded against a range of submaximal loads during the bench press (BP) exercise performed in a Smith machine using different grip widths. Sixteen physically active men (BP one-repetition maximum [1R...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2020 |
| País: | España |
| Institución: | Universidad de León |
| Repositorio: | BULERIA. Repositorio Institucional de la Universidad de León |
| OAI Identifier: | oai:buleria.unileon.es:10612/27204 |
| Acceso en línea: | https://hdl.handle.net/10612/27204 |
| Access Level: | acceso abierto |
| Palabra clave: | Deporte Educación Física Bar displacement Smith machine Linear position transducer Maximum velocity Mean velocity Velocity-based training |
| Sumario: | [EN] This study aimed to compare the within-session reliability and magnitude of velocity variables recorded against a range of submaximal loads during the bench press (BP) exercise performed in a Smith machine using different grip widths. Sixteen physically active men (BP one-repetition maximum [1RM] relative to body mass = 1.01 ± 0.19 kg·kg−1) were randomly tested on 4 sessions using a close grip width (100% of biacromial width), medium grip width (150% of biacromial width), wide grip width (200% of biacromial width), and self-selected grip width (176 ± 17% of biacromial width). Mean velocity (MV), maximum velocity (Vmax), and vertical displacement were recorded with a linear velocity transducer against the 35%1RM, 55%1RM, and 75%1RM. The main findings revealed that (I) the self-selected was the only grip width with an acceptable reliability for all loads and velocity variables (CV ≤ 7.56%; ICC ≥ 0.82), (II) the medium grip width provided the highest reliability for MV (CV ratio ≥ 1.20), while a comparable reliability was observed for Vmax using the close, medium and self-selected grip widths (CV ratio ≤ 1.08), (III) the Vmax showed the highest reliability for all grip widths (CV ratio = 1.68), and (IV) the MV and vertical displacement of the barbell were generally higher for narrow grip widths (close and medium) compared to the wide and self-selected grip widths, while no significant differences between the grip widths were observed for Vmax (p > .05). Taken together, we recommend the assessment of Vmax using a self-selected grip width during the routine testing of BP performance against submaximal loads. |
|---|