Mid-infrared T-shaped photonic crystal waveguide for optical refractive index sensing

In this paper, we propose and design a new type of an integrated optical sensor that performs sensing in a wide wavelength range corresponding to mid-infrared (mid-IR) spectrum. By engineering the structural parameters of square-lattice photonic crystal (PC) slab incorporated with a T-shaped air-slo...

ver descrição completa

Detalhes bibliográficos
Autores: Turduev, Mirbek, Giden, I., Giden, Ibrahim H., Babayigit, Ceren, Bor, Emre, Boztug, Çiçek, Kurt, Hamza, Staliunas, Kestutis|||0000-0002-0539-9538
Tipo de documento: artigo
Data de publicação:2017
País:España
Recursos:Universitat Politècnica de Catalunya (UPC)
Repositório:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglês
OAI Identifier:oai:upcommons.upc.edu:2117/105555
Acesso em linha:https://hdl.handle.net/2117/105555
https://dx.doi.org/10.1016/j.snb.2017.02.016
Access Level:Acceso aberto
Palavra-chave:Photonic crystals
Photonics
photonic crystals
bio-chemical sensing
slotted waveguides
label free optical sensors
refractive index based sensors
Cristalls fotònics
Detectors òptics
Fotònica
Àrees temàtiques de la UPC::Física
Descrição
Resumo:In this paper, we propose and design a new type of an integrated optical sensor that performs sensing in a wide wavelength range corresponding to mid-infrared (mid-IR) spectrum. By engineering the structural parameters of square-lattice photonic crystal (PC) slab incorporated with a T-shaped air-slot, strong light confinement and interaction with the analytes are assured. Numerical analyses in the time and frequency domain are conducted to determine the structural parameters of the design. The direct interaction between the slot waveguide mode and the analyte infiltrated into the slot gives rise to highly sensitive refractive index sensors. The highest sensitivity of the proposed T-slotted PC sensor is 1040 nm/RIU within the range of analytes’ refractive indices n = 1.05-1.10, and the overall sensitivity corresponding to the higher refractive index range of n = 1.10-1.30 is around 500 nm/RIU. Moreover, for a realistic PC slab structure, we determined an average refractive index sensitivity of 530 nm/RIU within the range of n = 1.10-1.25 and an average sensitivity of 390 nm/RIU within the range of n = 1.00-1.30. Furthermore, we speculate on the possible approach for the fabrication and the optical characterization of the device. The assets of the device include being compact, having a feasible measurement and fabrication technique, and possessing label-free sensing characteristic. We expect that the presented work may lead to the further development of the mid-IR label-free biochemical sensor devices for detection of various materials and gases in the near future.