Reliability-based assessment of the partial factor for shear design of fibre reinforced concrete members without shear reinforcement

Fibre reinforced concrete (FRC) is increasingly used for structural purposes owing to its many benefits, especially in terms of improved overall sustainability of FRC structures relative to traditional reinforced concrete (RC). Such increased structural use of FRC requires safe and reliable models f...

Descripción completa

Detalles Bibliográficos
Autores: Bairán García, Jesús Miguel|||0000-0003-2831-1479, Tošić, Nikola|||0000-0003-0242-8804, Fuente Antequera, Albert de la|||0000-0002-8016-1677
Tipo de recurso: artículo
Fecha de publicación:2021
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/353075
Acceso en línea:https://hdl.handle.net/2117/353075
https://dx.doi.org/10.1617/s11527-021-01773-z
Access Level:acceso abierto
Palabra clave:Fiber-reinforced concrete--Mechanical properties
Fiber reinforced concrete
Beam
Reliability
Safety format
Database
Design
FORM
Construcció en formigó armat -- Resistència
Àrees temàtiques de la UPC::Enginyeria civil::Materials i estructures::Materials i estructures de formigó
Descripción
Sumario:Fibre reinforced concrete (FRC) is increasingly used for structural purposes owing to its many benefits, especially in terms of improved overall sustainability of FRC structures relative to traditional reinforced concrete (RC). Such increased structural use of FRC requires safe and reliable models for its design in ultimate limit states (ULS). Particularly important are models for shear strength of FRC members without shear resistance due to the potential of brittle failure. The fib Model Code 2010 contains a model for the shear strength of FRC members without shear reinforcement and the same partial factor accepted for RC structures is accepted for FRC elements. This approach, however, is potentially on the unsafe side since the uncertainties of some design-determining mechanical properties of FRC (i.e., residual flexural strength) are larger than those for RC. Therefore, in this study, a comprehensive reliability-based calibration of the partial factor γc for the shear design of FRC members without shear reinforcement according to the fib Model Code 2010 model is performed. As a first step, the model error δ is assessed on 332 experimental results. Then, a parametric analysis of 700 cases is performed and a relationship between the target failure probability βR and γc is established. The results demonstrate that the current model together with the prescribed value of γc = 1.50 does not comply with the failure probabilities accepted for the different consequences of failure of FRC members over a 50-year service life. Therefore, changes to the shear resistance model are proposed in order to achieve the target failure probabilities.