Longitudinal Chromatic Aberration in Patients Implanted With Trifocal Diffractive Hydrophobic IOLs

PURPOSE: To measure the in vivo longitudinal chromatic aberration (LCA) from the chromatic difference of focus (480 to 700 nm) using psychophysical methods in patients bilaterally implanted with a hydrophobic trifocal intraocular lens (IOL). METHODS: Psychophysical best focus was measured in both ey...

ver descrição completa

Detalhes bibliográficos
Autores: Viñas Pérez, María, González Ramos, Ana María, Aisatti, Sara, Garzón Jiménez, Nuria, Poyales Galán, Francisco, Dorronsoro Díaz, Carlos, Marcos Celestino, Susana
Tipo de documento: artigo
Data de publicação:2020
País:España
Recursos:Universidad Complutense de Madrid (UCM)
Repositório:Docta Complutense
Idioma:inglês
OAI Identifier:oai:docta.ucm.es:20.500.14352/7634
Acesso em linha:https://hdl.handle.net/20.500.14352/7634
Access Level:Acceso aberto
Palavra-chave:617.7-089.243
681.73
535.313.6
612.843.31
617.75
IOLs
Trifocal lens
Chromatic aberration
Trifocal diffractive lens
Hydrophobic IOLS
Cirugía
Oftalmología
Optometría
Óptica oftálmica
Materiales ópticos
3213 Cirugía
3201.09 Oftalmología
2209.15 Optometría
2209.14 Propiedad ópticas de los sólidos
Descrição
Resumo:PURPOSE: To measure the in vivo longitudinal chromatic aberration (LCA) from the chromatic difference of focus (480 to 700 nm) using psychophysical methods in patients bilaterally implanted with a hydrophobic trifocal intraocular lens (IOL). METHODS: Psychophysical best focus was measured in both eyes at different wavelengths (480 to 700 nm) and at three different viewing distances (0.00, +1.75, and +3.50 diopters [D]) using a custom-developed polychromatic adaptive optics set-up provided with a supercontinuum laser, a Hartmann-Shack wavefront sensor, a deformable mirror, a motorized Badal system, a pupil monitoring system, and a psychophysical channel with monochromatically illuminated stimuli. Measurements were performed on 10 patients (20 eyes) bilaterally implanted with hydrophobic trifocal diffractive IOLs (FineVisionHP POD F GF; PhysIOL). LCA was computed from the chromatic difference of focus curves as the difference between 480 and 700 nm at near, intermediate, and far. RESULTS:The LCA from psychophysical measurements was significantly higher for far vision (0.99 ± 0.06 diopters [D]), than for intermediate (0.67 ± 0.10 D) and near (0.23 ± 0.08 D) vision (one-way analysis of variance, P < .05). CONCLUSIONS: LCA for far vision was significantly higher than for intermediate and near vision in hydrophobic trifocal diffractive IOLs, in agreement with a previous study with the same optical design but hydrophilic material IOLs. The LCA for the hydro-phobic IOL is slightly higher than for the hydrophilic IOL at far. Different combinations of refractive and diffractive LCA will allow optimizing IOL designs to improve polychromatic image quality.