Model observers applied to low contrast detectability in computed tomography

Introduction. Medical imaging has become one of the comerstones in modem healthcare. Computed tomography (CT) is a widely used imaging modality in radiology worldwide. This technique allows to obtain three-dimensional volume reconstructions ofdifferent parts of the patient with isotropic spatial res...

Descripción completa

Detalles Bibliográficos
Autor: Hernández Girón, Irene
Tipo de recurso: tesis doctoral
Fecha de publicación:2017
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/21907
Acceso en línea:https://hdl.handle.net/20.500.14352/21907
Access Level:acceso abierto
Palabra clave:616-073.7(043.2)
Computed tomography
Tomografía Computarizada
Diagnóstico por imagen y medicina nuclear
3204.01 Medicina Nuclear
id ES_ea917249fa43b2a52e0a424bb28b29f3
oai_identifier_str oai:docta.ucm.es:20.500.14352/21907
network_acronym_str ES
network_name_str España
repository_id_str
dc.title.none.fl_str_mv Model observers applied to low contrast detectability in computed tomography
Modelos de observador aplicados a la detectabilidad de bajo contraste en tomografía computarizada
title Model observers applied to low contrast detectability in computed tomography
spellingShingle Model observers applied to low contrast detectability in computed tomography
Hernández Girón, Irene
616-073.7(043.2)
Computed tomography
Tomografía Computarizada
Diagnóstico por imagen y medicina nuclear
3204.01 Medicina Nuclear
title_short Model observers applied to low contrast detectability in computed tomography
title_full Model observers applied to low contrast detectability in computed tomography
title_fullStr Model observers applied to low contrast detectability in computed tomography
title_full_unstemmed Model observers applied to low contrast detectability in computed tomography
title_sort Model observers applied to low contrast detectability in computed tomography
dc.creator.none.fl_str_mv Hernández Girón, Irene
author Hernández Girón, Irene
author_facet Hernández Girón, Irene
author_role author
dc.contributor.none.fl_str_mv Calzado Cantera, Alfonso
Veldkamp, Wouter J.H.
Universidad Complutense de Madrid
dc.subject.none.fl_str_mv 616-073.7(043.2)
Computed tomography
Tomografía Computarizada
Diagnóstico por imagen y medicina nuclear
3204.01 Medicina Nuclear
topic 616-073.7(043.2)
Computed tomography
Tomografía Computarizada
Diagnóstico por imagen y medicina nuclear
3204.01 Medicina Nuclear
description Introduction. Medical imaging has become one of the comerstones in modem healthcare. Computed tomography (CT) is a widely used imaging modality in radiology worldwide. This technique allows to obtain three-dimensional volume reconstructions ofdifferent parts of the patient with isotropic spatial resolution. Also, to acquire sharp images of moving organs, such as the heart orthe lungs, without artifacts. The spectrum ofindications which can be tackled with this technique is wide, and it comprises brain perfusion, cardiology, oncology, vascular radiology, interventionism and traumatology, amongst others. CT is a very popular imaging technique, widely implanted in healthcare services worldwide. The amount of CT scans performed per year has been continuously growing in the past decades, which has led to a great benefit for the patients. At the same time, CT exams represent the highest contribution to the collective radiation dose. Patient dose in CT is one order ofmagnitude higher than in conventional X-ray studies. Regarding patient dose in X-ray imaging the ALARA criteria is universally accepted. It states that patient images should be obtained using adose as low as reasonably achievable and compatible with the diagnostic task. Sorne cases ofpatients' radiation overexposure, most ofthem in brain perfusion procedures have come to the public eye and hada great impact in the USA media. These cases, together with the increasing number ofCT scans performed per year, have raised a red flag about the patient imparted doses in CT. Several guidelines and recommendation for dose optimization in CT have been published by different organizations, which have been included in European and National regulations and adopted by CT manufacturers. In CT, the X-ray tube is rotating around the patient, emitting photons in beams from different angles or projections. These photons interact with the tissues in the patient, depending on their energy and the tissue composition and density. A fraction of these photons deposit all or part of their energy inside the patient, resulting in organs absorbed dose. The images are generated using the data from the projections ofthe X-ray beam that reach the detectors after passing through the patient. Each proj ection represents the total integrated attenuation of the X-ray beam along its path. A CT protocol is defined as a collection of settings which can be selected in the CT console and affect the image quality outcome and the patient dose. They can be acquisition parameters such as beam collimation, tube current, rotation time, kV, pitch, or reconstruction parameters such as the slice thickness and spacing, reconstruction filter and method (filtered back projection (FBP) or iterative algorithms). All main CT manufacturers offer default protocols for different indications, depending on the anatomical region. The user can frequently set the protocol parameters selecting amongst a range of values to adapt them to the clinical indication and patient characteristics, such as size or age. The selected settings in the protocol affect greatly image quality and dose. Many combinations ofsean parameters can render an appropriate image quality for a particular study. Protocol optimization is a complex task in CT because most sean protocol parameters are intertwined and affect image quality and patient dose...
publishDate 2017
dc.date.none.fl_str_mv 2017
2017-03-01
2017
2017-03-01
dc.type.none.fl_str_mv doctoral thesis
http://purl.org/coar/resource_type/c_db06
dc.type.openaire.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
dc.identifier.none.fl_str_mv https://hdl.handle.net/20.500.14352/21907
url https://hdl.handle.net/20.500.14352/21907
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidad Complutense de Madrid
publisher.none.fl_str_mv Universidad Complutense de Madrid
dc.source.none.fl_str_mv reponame:Docta Complutense
instname:Universidad Complutense de Madrid (UCM)
instname_str Universidad Complutense de Madrid (UCM)
reponame_str Docta Complutense
collection Docta Complutense
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869423150930853888
spelling Model observers applied to low contrast detectability in computed tomographyModelos de observador aplicados a la detectabilidad de bajo contraste en tomografía computarizadaHernández Girón, Irene616-073.7(043.2)Computed tomographyTomografía ComputarizadaDiagnóstico por imagen y medicina nuclear3204.01 Medicina NuclearIntroduction. Medical imaging has become one of the comerstones in modem healthcare. Computed tomography (CT) is a widely used imaging modality in radiology worldwide. This technique allows to obtain three-dimensional volume reconstructions ofdifferent parts of the patient with isotropic spatial resolution. Also, to acquire sharp images of moving organs, such as the heart orthe lungs, without artifacts. The spectrum ofindications which can be tackled with this technique is wide, and it comprises brain perfusion, cardiology, oncology, vascular radiology, interventionism and traumatology, amongst others. CT is a very popular imaging technique, widely implanted in healthcare services worldwide. The amount of CT scans performed per year has been continuously growing in the past decades, which has led to a great benefit for the patients. At the same time, CT exams represent the highest contribution to the collective radiation dose. Patient dose in CT is one order ofmagnitude higher than in conventional X-ray studies. Regarding patient dose in X-ray imaging the ALARA criteria is universally accepted. It states that patient images should be obtained using adose as low as reasonably achievable and compatible with the diagnostic task. Sorne cases ofpatients' radiation overexposure, most ofthem in brain perfusion procedures have come to the public eye and hada great impact in the USA media. These cases, together with the increasing number ofCT scans performed per year, have raised a red flag about the patient imparted doses in CT. Several guidelines and recommendation for dose optimization in CT have been published by different organizations, which have been included in European and National regulations and adopted by CT manufacturers. In CT, the X-ray tube is rotating around the patient, emitting photons in beams from different angles or projections. These photons interact with the tissues in the patient, depending on their energy and the tissue composition and density. A fraction of these photons deposit all or part of their energy inside the patient, resulting in organs absorbed dose. The images are generated using the data from the projections ofthe X-ray beam that reach the detectors after passing through the patient. Each proj ection represents the total integrated attenuation of the X-ray beam along its path. A CT protocol is defined as a collection of settings which can be selected in the CT console and affect the image quality outcome and the patient dose. They can be acquisition parameters such as beam collimation, tube current, rotation time, kV, pitch, or reconstruction parameters such as the slice thickness and spacing, reconstruction filter and method (filtered back projection (FBP) or iterative algorithms). All main CT manufacturers offer default protocols for different indications, depending on the anatomical region. The user can frequently set the protocol parameters selecting amongst a range of values to adapt them to the clinical indication and patient characteristics, such as size or age. The selected settings in the protocol affect greatly image quality and dose. Many combinations ofsean parameters can render an appropriate image quality for a particular study. Protocol optimization is a complex task in CT because most sean protocol parameters are intertwined and affect image quality and patient dose...Universidad Complutense de MadridCalzado Cantera, AlfonsoVeldkamp, Wouter J.H.Universidad Complutense de Madrid20172017-03-0120172017-03-01doctoral thesishttp://purl.org/coar/resource_type/c_db06info:eu-repo/semantics/doctoralThesisapplication/pdfhttps://hdl.handle.net/20.500.14352/21907reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/219072026-06-02T12:44:21Z
score 15,301603