Velocity-space analysis of fast-ion losses measured in MAST-U using a high-speed camera in the FILD detector

A fast-ion loss detector (FILD) was installed for the first time at the mega amp spherical tokamak—upgrade (MAST-U) spherical tokamak during its upgrade in 2021. A new CMOS camera was installed in the MAST-U FILD acquisition system to provide high spatial resolution (1.1 MPx) with an acquisition fre...

Descripción completa

Detalles Bibliográficos
Autores: Velarde, Lina, Rivero-Rodriguez, J.F., Galdón Quiroga, Joaquín, Williams, T., Rueda-Rueda, José, Cano Megías, Pilar, Chacartegui, Ricardo, García-Muñoz, M., Blackmore, S., McClements, K. G., Sanchís Sánchez, Lucía, Viezzer, Eleonora
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2025
País:España
Institución:Consejo Superior de Investigaciones Científicas (CSIC)
Repositorio:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/383841
Acceso en línea:http://hdl.handle.net/10261/383841
https://api.elsevier.com/content/abstract/scopus_id/85219527932
Access Level:acceso abierto
Palabra clave:Fast-ion loss detector
Fast-ion losses
Spherical tokamaks
Velocity-space
ASCOT
Descripción
Sumario:A fast-ion loss detector (FILD) was installed for the first time at the mega amp spherical tokamak—upgrade (MAST-U) spherical tokamak during its upgrade in 2021. A new CMOS camera was installed in the MAST-U FILD acquisition system to provide high spatial resolution (1.1 MPx) with an acquisition frequency of up to 3.5 kHz. This camera has enabled the systematic analysis of the velocity-space of the fast-ion losses measured in MAST-U presented in this manuscript. The main parameters that determine the FILD measurement have been analysed to maximise the signal in the detector: the orbit-following code ASCOT predicts an inverse relation between the FILD signal and the probe’s relative distance to the separatrix. This prediction has been validated experimentally, enabling the measurement of fast-ion losses in the flat-top phase of the discharge; furthermore, ASCOT simulations show a big impact of the edge safety factor (q95) on the toroidal deposition of the prompt losses, indicating that the signal in the MAST-U FILD can be maximised by running scenarios with | q 95 | < 6 . This prediction was validated experimentally by a scan in the toroidal magnetic field. The experimental resolution of the MAST-U FILD has been evaluated for a typical MAST-U scenario with 750 kA plasma current. The results show that the diagnostic resolution is in the order of 0.5 to 1 degree in pitch angle, and of 1 to 3 cm in gyroradius in current scenarios. A systematic analysis of the velocity-space of the losses shows that the measured gyroradii of the prompt losses match those of the neutral beam injector injection energies within the resolution of the diagnostic. The experimentally measured pitch angles have been compared with ASCOT simulations, and it has been found that the agreement is better for scenarios heated with the on-axis beam, since this beam enables measurements of the magnetic field pitch angle. This analysis has been applied to a discharge where type-III ELM-induced fast-ion losses were measured, showing that the ELMs result in an increase in the FILD signal, and that the losses are coming from passing orbits.