Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients
This article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their ability to predict the visual quality of patients implanted with multifocal intraocular lenses (IOLs). The optical quality of IOLs is assessed i...
| Autores: | , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2020 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/331547 |
| Acceso en línea: | https://hdl.handle.net/2117/331547 https://dx.doi.org/10.1364/BOE.388531 |
| Access Level: | acceso abierto |
| Palabra clave: | Vision Intraocular lenses Visual acuity Visió Lents intraoculars Agudesa visual Àrees temàtiques de la UPC::Ciències de la visió |
| id |
ES_e8dff17be822639e68100ea7b415eb8f |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/331547 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patientsArmengol Cebrian, Jesús|||0000-0003-2880-752XGarzon, NuriaVega Lerín, Fidel|||0000-0002-8594-0872Altemir Gómez, I.Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373VisionIntraocular lensesVisual acuityVisióLents intraocularsAgudesa visualÀrees temàtiques de la UPC::Ciències de la visióThis article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their ability to predict the visual quality of patients implanted with multifocal intraocular lenses (IOLs). The optical quality of IOLs is assessed in vitro using two metrics, the MTFa and EE. We measured them for three different multifocal IOLs with parabolic phase profile using image formation, through-focus (TF) scanning, three R, G, B wavelengths, and two pupils. We analyzed the correlation between MTFa and EE. In parallel, clinical defocus curves of visual acuity (VA) were measured and averaged from sets of patients implanted with the same IOLs. An excellent linear correlation was found between the MTFa and EE for the considered IOLs, wavelengths and pupils (R2 > 0.9). We computed the polychromatic TF-MTFa, TF-EE, and derived mathematical relationships between each metrics and clinical average VA. MTFa and EE proved to be equivalent metrics to characterize the optical quality of the studied multifocal IOLs and also in terms of clinical VA predictability.Ministerio de Economía y Competitividad y fondos Feder (DPI2016-76019-R).Peer Reviewed20202020-05-0120202020-11-06journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/331547https://dx.doi.org/10.1364/BOE.388531reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/3315472026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients |
| title |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients |
| spellingShingle |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients Armengol Cebrian, Jesús|||0000-0003-2880-752X Vision Intraocular lenses Visual acuity Visió Lents intraoculars Agudesa visual Àrees temàtiques de la UPC::Ciències de la visió |
| title_short |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients |
| title_full |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients |
| title_fullStr |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients |
| title_full_unstemmed |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients |
| title_sort |
Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients |
| dc.creator.none.fl_str_mv |
Armengol Cebrian, Jesús|||0000-0003-2880-752X Garzon, Nuria Vega Lerín, Fidel|||0000-0002-8594-0872 Altemir Gómez, I. Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 |
| author |
Armengol Cebrian, Jesús|||0000-0003-2880-752X |
| author_facet |
Armengol Cebrian, Jesús|||0000-0003-2880-752X Garzon, Nuria Vega Lerín, Fidel|||0000-0002-8594-0872 Altemir Gómez, I. Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 |
| author_role |
author |
| author2 |
Garzon, Nuria Vega Lerín, Fidel|||0000-0002-8594-0872 Altemir Gómez, I. Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
Vision Intraocular lenses Visual acuity Visió Lents intraoculars Agudesa visual Àrees temàtiques de la UPC::Ciències de la visió |
| topic |
Vision Intraocular lenses Visual acuity Visió Lents intraoculars Agudesa visual Àrees temàtiques de la UPC::Ciències de la visió |
| description |
This article studies the relationship between two metrics, the area under the modulation transfer function (MTFa) and the energy efficiency (EE), and their ability to predict the visual quality of patients implanted with multifocal intraocular lenses (IOLs). The optical quality of IOLs is assessed in vitro using two metrics, the MTFa and EE. We measured them for three different multifocal IOLs with parabolic phase profile using image formation, through-focus (TF) scanning, three R, G, B wavelengths, and two pupils. We analyzed the correlation between MTFa and EE. In parallel, clinical defocus curves of visual acuity (VA) were measured and averaged from sets of patients implanted with the same IOLs. An excellent linear correlation was found between the MTFa and EE for the considered IOLs, wavelengths and pupils (R2 > 0.9). We computed the polychromatic TF-MTFa, TF-EE, and derived mathematical relationships between each metrics and clinical average VA. MTFa and EE proved to be equivalent metrics to characterize the optical quality of the studied multifocal IOLs and also in terms of clinical VA predictability. |
| publishDate |
2020 |
| dc.date.none.fl_str_mv |
2020 2020-05-01 2020 2020-11-06 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/331547 https://dx.doi.org/10.1364/BOE.388531 |
| url |
https://hdl.handle.net/2117/331547 https://dx.doi.org/10.1364/BOE.388531 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869422979332440064 |
| score |
15,300724 |