Experimental study of effectiveness of four radon mitigation solutions, based on underground depressurization, tested in prototype housing built in a high radon area in Spain

The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a...

Descripción completa

Detalles Bibliográficos
Autores: Frutos Vázquez, Borja, Olaya Adán, Manuel, Quindós Poncela, Luis Santiago, Sainz Fernández, Carlos, Fuente Merino, Ismael
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2011
País:España
Institución:Consejo Superior de Investigaciones Científicas (CSIC)
Repositorio:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/50406
Acceso en línea:http://hdl.handle.net/10261/50406
Access Level:acceso abierto
Palabra clave:Radon
Mitigating measures
Prevention
Sump solutions
Efficiency
radon
Descripción
Sumario:The present paper discusses the results of an empirical study of four approaches to reducing indoor radon concentrations based on depressurization techniques in underground sumps. The experiments were conducted in prototype housing built in an area of Spain where the average radon concentration at a depth of 1 m is 250 kBq m−3. Sump effectiveness was analysed in two locations: underneath the basement, which involved cutting openings into the foundation, ground storey and roof slabs, and outside the basement walls, which entailed digging a pit alongside the building exterior. The effectiveness of both sumps was likewise tested with passive and forced ventilation methods. The systems proved to be highly efficient, lowering radon levels by 91–99%, except in the solution involving passive ventilation and the outside sump, where radon levels were reduced by 53–55%. At wind speeds of over 8 m/s, however, passive ventilation across an outside sump lowered radon levels by 95% due to a Venturi effect induced drop in pressure.