Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode

Copyright: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).

Bibliographic Details
Authors: Carballar Rincón, Alejandro, Rodríguez-Garrido, Roberto, Jerez González, Manuel, Vera, Jonathan, Granado Romero, Joaquín
Format: article
Status:Published version
Publication Date:2024
Country:España
Institution:Universidad de Sevilla (US)
Repository:idUS. Depósito de Investigación de la Universidad de Sevilla
OAI Identifier:oai:idus.us.es:11441/164234
Online Access:https://hdl.handle.net/11441/164234
https://doi.org/10.3390/s24113674
Access Level:Open access
Keyword:Radiometer
Pyrheliometer
Solar irradiance
Optical fiber
Semiconductor photodiode
Spectral irradiance
Acceptance cone
id ES_df1fa3186b95eca27a9cace3efdc4fc1
oai_identifier_str oai:idus.us.es:11441/164234
network_acronym_str ES
network_name_str España
repository_id_str
spelling Measuring DNI with a New Radiometer Based on an Optical Fiber and PhotodiodeCarballar Rincón, AlejandroRodríguez-Garrido, RobertoJerez González, ManuelVera, JonathanGranado Romero, JoaquínRadiometerPyrheliometerSolar irradianceOptical fiberSemiconductor photodiodeSpectral irradianceAcceptance coneCopyright: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).A new cost-effective radiometer has been designed, built, and tested to measure direct normal solar irradiance (DNI). The proposed instrument for solar irradiance measurement is based on an optical fiber as the light beam collector, a semiconductor photodiode to measure the optical power, and a calibration algorithm to convert the optical power into solar irradiance. The proposed radiometer offers the advantage of separating the measurement point, where the optical fiber collects the solar irradiation, from the place where the optical power is measured. A calibration factor is mandatory because the semiconductor photodiode is only spectrally responsive to a limited part of the spectral irradiance. Experimental tests have been conducted under different conditions to evaluate the performance of the proposed device. The measurements confirm that the proposed instrument performs similarly to the expensive high-accuracy pyrheliometer used as a reference.Multidisciplinary Digital Publishing Institute (MDPI)Ingeniería ElectrónicaTIC192: Ingeniería electrónicaTIC231: Fotónica de ComunicacionesMinisterio de Ciencia e Innovación (MICIN). EspañaAgencia Estatal de Investigación. EspañaEuropean Union (UE). Horizon Europe2024info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttps://hdl.handle.net/11441/164234https://doi.org/10.3390/s24113674reponame:idUS. Depósito de Investigación de la Universidad de Sevillainstname:Universidad de Sevilla (US)InglésSensors, 24 (11), 3674.PID2021-125786OB-C22TED2021-132190BC22https://www.mdpi.com/1424-8220/24/11/3674info:eu-repo/semantics/openAccessoai:idus.us.es:11441/1642342026-06-17T12:51:07Z
dc.title.none.fl_str_mv Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
title Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
spellingShingle Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
Carballar Rincón, Alejandro
Radiometer
Pyrheliometer
Solar irradiance
Optical fiber
Semiconductor photodiode
Spectral irradiance
Acceptance cone
title_short Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
title_full Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
title_fullStr Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
title_full_unstemmed Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
title_sort Measuring DNI with a New Radiometer Based on an Optical Fiber and Photodiode
dc.creator.none.fl_str_mv Carballar Rincón, Alejandro
Rodríguez-Garrido, Roberto
Jerez González, Manuel
Vera, Jonathan
Granado Romero, Joaquín
author Carballar Rincón, Alejandro
author_facet Carballar Rincón, Alejandro
Rodríguez-Garrido, Roberto
Jerez González, Manuel
Vera, Jonathan
Granado Romero, Joaquín
author_role author
author2 Rodríguez-Garrido, Roberto
Jerez González, Manuel
Vera, Jonathan
Granado Romero, Joaquín
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Ingeniería Electrónica
TIC192: Ingeniería electrónica
TIC231: Fotónica de Comunicaciones
Ministerio de Ciencia e Innovación (MICIN). España
Agencia Estatal de Investigación. España
European Union (UE). Horizon Europe
dc.subject.none.fl_str_mv Radiometer
Pyrheliometer
Solar irradiance
Optical fiber
Semiconductor photodiode
Spectral irradiance
Acceptance cone
topic Radiometer
Pyrheliometer
Solar irradiance
Optical fiber
Semiconductor photodiode
Spectral irradiance
Acceptance cone
description Copyright: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/ 4.0/).
publishDate 2024
dc.date.none.fl_str_mv 2024
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv https://hdl.handle.net/11441/164234
https://doi.org/10.3390/s24113674
url https://hdl.handle.net/11441/164234
https://doi.org/10.3390/s24113674
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv Sensors, 24 (11), 3674.
PID2021-125786OB-C22
TED2021-132190BC22
https://www.mdpi.com/1424-8220/24/11/3674
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Multidisciplinary Digital Publishing Institute (MDPI)
publisher.none.fl_str_mv Multidisciplinary Digital Publishing Institute (MDPI)
dc.source.none.fl_str_mv reponame:idUS. Depósito de Investigación de la Universidad de Sevilla
instname:Universidad de Sevilla (US)
instname_str Universidad de Sevilla (US)
reponame_str idUS. Depósito de Investigación de la Universidad de Sevilla
collection idUS. Depósito de Investigación de la Universidad de Sevilla
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869422035790200832
score 15,812429