The effect of soft contact lens thickness in visual function after intracorneal ring segments surgery

Objective: To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery. Methods: A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patien...

Descripción completa

Detalles Bibliográficos
Autores: Carracedo Rodríguez, Juan Gonzalo, Canales Calvo, Javier, González Balboa, Paula, Recchioni, Alberto, Carpena Torres, Carlos, Carballo Álvarez, Jesús
Tipo de recurso: artículo
Fecha de publicación:2017
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/18254
Acceso en línea:https://hdl.handle.net/20.500.14352/18254
Access Level:acceso abierto
Palabra clave:617.713-089
617.7-089.243
617.75
Keratoconus
Intracorneal rings
Visual function
Contact lenses
Cirugía
Lentes de contacto
Optometría
3213 Cirugía
3311.11 Instrumentos ópticos
2209.15 Optometría
Descripción
Sumario:Objective: To study the influence of soft contact lens (SCL) central thickness and material in keratoconus on visual function after intracorneal ring segment (ICRS) surgery. Methods: A pilot, experimental, prospective, cross-sectional and double-blind study was performed. Fourteen keratoconus patients with age range of 34.75 ± 9.22 years (7 males and 7 females) with ICRS implanted were involved in the study. Two different SCL materials [Hioxifilcon A (G-5X/p-GMA/HEMA) and Lucifilcon A (silicone-hydrogel)] with four different central thicknesses (0.1, 0.2, 0.3 and 0.4 mm) were fitted in one eye per patient, selected randomly. High and low corrected distance visual acuity (CDVA) and contrast sensitivity (CS), corneal topography and corneal and total aberrometry were measured. Results: Corneal spherical like, coma like and root mean square (RMS) decreased significantly for 0.3 and 0.4 mm in both SCL materials (p < 0.05). Total RMS decreased significantly for 0.4 mm with both SCL materials (p < 0.05). High and low CDVA improved for 0.4 mm of thickness for both materials (p < 0.05). Statistically increasing were found in all thicknesses studied for CS in both materials (p < 0.05). Conclusion: A central thickness of the SCL equal or superior to 0.4 mm seems to decrease the ocular high order aberration (HOA) and to improve the visual function in keratoconus patients implanted with ICRS. However, the modulus of rigidity of the SCL would not influence the HOA correction.