Desorption electrospray ionization-high resolution mass spectrometry for the screening of veterinary drugs in cross contaminated feddstuffs

In this study, a desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) screening method was developed for fast identification of veterinary drugs in cross-contaminated feedstuffs. The reliable detection was performed working at high resolution (70,000 full with half maximu...

Descripción completa

Detalles Bibliográficos
Autores: Seró Llor, Raquel, Núñez Burcio, Oscar, Bosch i Genover, Jaume, Grases, Josep M., Rodríguez, Pilar, Moyano Morcillo, Encarnación, Galcerán Huguet, M. Teresa
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2015
País:España
Institución:Universidad de Barcelona
Repositorio:Dipòsit Digital de la UB
OAI Identifier:oai:diposit.ub.edu:2445/98431
Acceso en línea:https://hdl.handle.net/2445/98431
Access Level:acceso abierto
Palabra clave:Medicaments veterinaris
Espectrometria de masses amb ionització per electroesprai
Veterinary drugs
Electrospray ionization mass spectrometry
Descripción
Sumario:In this study, a desorption electrospray ionization-high resolution mass spectrometry (DESI-HRMS) screening method was developed for fast identification of veterinary drugs in cross-contaminated feedstuffs. The reliable detection was performed working at high resolution (70,000 full with half maximum, FWHM) using an orbitrap mass analyser. Among the optimized DESI parameters, the solvent (acetonitrile-water, 80:20, v/v) and the sample substrate (poly-tetrafluoroethylene, PTFE) were critical to obtain the best sensitivity. To analyse the solid feed samples, different approaches were tested and a simple solid-liquid extraction and the direct analysis of an aliquot (2 μL) of the extract after let it dry on the PTFE printed spot provided the best results. The identification of the veterinary drugs (target and non-target) in the cross-contaminated feedstuffs based on the accurate mass measurement and the isotopic pattern fit was performed automatically using a custom-made database. The positive crosscontaminated feed samples were quantified by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). The results obtained demonstrate that DESI-HRMS can be proposed as a fast and suitable screening method to identify positive cross-contaminated feedstuffs reducing the number of samples to be subsequently quantified by UHPLC-MS/MS thus improving the productivity in quality control laboratories.