Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol.
Background/objectives: Cooling strategies are critical for optimizing athlete recovery and performance in team sports, yet practical, accessible solutions remain underexplored. This study evaluated the efficacy of a cool vest during a 15 min recovery period following 45 min of simulated soccer match...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2025 |
| País: | España |
| Institución: | Universidad de Oviedo (UNIOVI) |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:dnet:ubarcelona__::3b63c00408f1223d373e52bd6c861a47 |
| Acceso en línea: | https://hdl.handle.net/2445/229295 |
| Access Level: | acceso abierto |
| Palabra clave: | Crioteràpia Rendiment esportiu Cryotherapy Athletic performance |
| id |
ES_dca5ee217c77f6fe8116d4ddfd11d6ce |
|---|---|
| oai_identifier_str |
oai:dnet:ubarcelona__::3b63c00408f1223d373e52bd6c861a47 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol.Lorente González, CarlosBeltrán Garrido, José VicenteBatalla Gavaldà, AbrahamCorbi, FranciscoCrioteràpiaRendiment esportiuCryotherapyAthletic performanceBackground/objectives: Cooling strategies are critical for optimizing athlete recovery and performance in team sports, yet practical, accessible solutions remain underexplored. This study evaluated the efficacy of a cool vest during a 15 min recovery period following 45 min of simulated soccer match play on core and skin temperature regulation. Methods: Forty-seven physically active males completed an exercise protocol replicating the physiological demands of a soccer half-match. Participants were randomized into an experimental group using a cool vest during recovery (IG, n = 24) or a control group (CG, n = 23) without cooling intervention. Results: Compared to CG, IG exhibited small but significant reductions in skin temperature (31.46 ± 0.67 °C vs. 32.40 ± 1.04 °C; ES = -0.24, 95% CI: -0.40 to -0.08; p = 0.003) and tympanic temperature (35.99 ± 0.45 °C vs. 36.54 ± 0.66 °C; ES = -0.43, 95% CI: -0.67 to -0.18; p < 0.001) 10 min post-exercise. These differences intensified to small and moderate effects at 15 min post-exercise for skin (31.07 ± 0.67 °C vs. 32.51 ± 0.91 °C; ES = -0.37, 95% CI: -0.53 to -0.21; p < 0.001) and tympanic temperatures (35.70 ± 0.42 °C vs. 36.65 ± 0.58 °C; ES = -0.71, 95% CI: -0.96 to -0.46; p < 0.001), respectively, with IG maintaining consistently lower values. No temperature changes were observed in CG. Conclusions: These findings demonstrate that a 15 min cool vest application during halftime effectively reduces core and skin temperatures, compared to passive recovery. This supports its utility as a practical, low-cost strategy for thermoregulatory management in soccer, warranting further investigation into its long-term performance benefits.MDPI2025info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/229295Articles publicats en revistes (Ciències Clíniques)reponame:Dipòsit Digital de la UBinstname:Universidad de Oviedo (UNIOVI)InglésReproducció del document publicat a: https://doi.org/10.3390/sports13070235Sports, 2025, vol. 13, num.7https://doi.org/10.3390/sports13070235cc-by (c) Lorente-González, C. et al., 2025http://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:dnet:ubarcelona__::3b63c00408f1223d373e52bd6c861a472026-05-27T06:46:51Z |
| dc.title.none.fl_str_mv |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol. |
| title |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol. |
| spellingShingle |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol. Lorente González, Carlos Crioteràpia Rendiment esportiu Cryotherapy Athletic performance |
| title_short |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol. |
| title_full |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol. |
| title_fullStr |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol. |
| title_full_unstemmed |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol. |
| title_sort |
Effects of a cooling vest on core and skin temperatures following a soccer-specific exercise protocol. |
| dc.creator.none.fl_str_mv |
Lorente González, Carlos Beltrán Garrido, José Vicente Batalla Gavaldà, Abraham Corbi, Francisco |
| author |
Lorente González, Carlos |
| author_facet |
Lorente González, Carlos Beltrán Garrido, José Vicente Batalla Gavaldà, Abraham Corbi, Francisco |
| author_role |
author |
| author2 |
Beltrán Garrido, José Vicente Batalla Gavaldà, Abraham Corbi, Francisco |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Crioteràpia Rendiment esportiu Cryotherapy Athletic performance |
| topic |
Crioteràpia Rendiment esportiu Cryotherapy Athletic performance |
| description |
Background/objectives: Cooling strategies are critical for optimizing athlete recovery and performance in team sports, yet practical, accessible solutions remain underexplored. This study evaluated the efficacy of a cool vest during a 15 min recovery period following 45 min of simulated soccer match play on core and skin temperature regulation. Methods: Forty-seven physically active males completed an exercise protocol replicating the physiological demands of a soccer half-match. Participants were randomized into an experimental group using a cool vest during recovery (IG, n = 24) or a control group (CG, n = 23) without cooling intervention. Results: Compared to CG, IG exhibited small but significant reductions in skin temperature (31.46 ± 0.67 °C vs. 32.40 ± 1.04 °C; ES = -0.24, 95% CI: -0.40 to -0.08; p = 0.003) and tympanic temperature (35.99 ± 0.45 °C vs. 36.54 ± 0.66 °C; ES = -0.43, 95% CI: -0.67 to -0.18; p < 0.001) 10 min post-exercise. These differences intensified to small and moderate effects at 15 min post-exercise for skin (31.07 ± 0.67 °C vs. 32.51 ± 0.91 °C; ES = -0.37, 95% CI: -0.53 to -0.21; p < 0.001) and tympanic temperatures (35.70 ± 0.42 °C vs. 36.65 ± 0.58 °C; ES = -0.71, 95% CI: -0.96 to -0.46; p < 0.001), respectively, with IG maintaining consistently lower values. No temperature changes were observed in CG. Conclusions: These findings demonstrate that a 15 min cool vest application during halftime effectively reduces core and skin temperatures, compared to passive recovery. This supports its utility as a practical, low-cost strategy for thermoregulatory management in soccer, warranting further investigation into its long-term performance benefits. |
| publishDate |
2025 |
| dc.date.none.fl_str_mv |
2025 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/229295 |
| url |
https://hdl.handle.net/2445/229295 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Reproducció del document publicat a: https://doi.org/10.3390/sports13070235 Sports, 2025, vol. 13, num.7 https://doi.org/10.3390/sports13070235 |
| dc.rights.none.fl_str_mv |
cc-by (c) Lorente-González, C. et al., 2025 http://creativecommons.org/licenses/by/4.0/ info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
cc-by (c) Lorente-González, C. et al., 2025 http://creativecommons.org/licenses/by/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Ciències Clíniques) reponame:Dipòsit Digital de la UB instname:Universidad de Oviedo (UNIOVI) |
| instname_str |
Universidad de Oviedo (UNIOVI) |
| reponame_str |
Dipòsit Digital de la UB |
| collection |
Dipòsit Digital de la UB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869421787795685376 |
| score |
15,812429 |