Comparison of video-based methods for respiration rhythm measurement
The aim of this work is to characterize the di erences in the respiratory rhythm obtained through three video based methods by comparing the obtained respiratory signals with the one obtained with the gold standard method in adult population. The analysed methods are an RGB camera, a depth camera an...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2019 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/130731 |
| Acceso en línea: | https://hdl.handle.net/2117/130731 https://dx.doi.org/10.1016/j.bspc.2019.02.004 |
| Access Level: | acceso abierto |
| Palabra clave: | Respiration - Measurement Pulmonary function tests Respiració -- Mesurament Aparell respiratori -- Proves funcionals Àrees temàtiques de la UPC::Enginyeria biomèdica |
| id |
ES_db9c90c7f0f6757f0d5a61ba22f675b0 |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/130731 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Comparison of video-based methods for respiration rhythm measurementMateu Mateus, Marc|||0000-0002-6849-7426Guede Fernández, Federico|||0000-0003-2762-0333Ferrer Mileo, VíctorGarcía González, Miguel Ángel|||0000-0002-8043-4794Ramos Castro, Juan José|||0000-0001-9413-2001Fernández Chimeno, Mireya|||0000-0001-8384-1320Respiration - MeasurementPulmonary function testsRespiració -- MesuramentAparell respiratori -- Proves funcionalsÀrees temàtiques de la UPC::Enginyeria biomèdicaThe aim of this work is to characterize the di erences in the respiratory rhythm obtained through three video based methods by comparing the obtained respiratory signals with the one obtained with the gold standard method in adult population. The analysed methods are an RGB camera, a depth camera and a thermal camera while the gold standard is an inductive thorax plethysmography system (Respiband system from BioSignals Plux). 21 healthy subjects where measured, performing 4 tests for each subject. The respiratory rhythm and its variability was obtained from the four respiratory signals (3 video methods and gold standard). The signal acquisition was performed with custom and proprietary algorithms. To characterize the respiratory rhythm and its variability obtained with the di erent video sources and gold standard, the instantaneous frequency, Bland-Altman plots and standard deviation of the error between video methods and the gold standard have been computed. The depth and RGB camera present high agreement with no statistical di erences between them, with errors when comparing with the gold standard in the range of mHz. The thermal camera performs poorly if compared with the two other methods, nevertheless it cannot be discarded directly because some errors produced by the subjects head movement could not be corrected. From these results we conclude that the depth and RGB camera, and their respective acquisition algorithms) can be used in controlled conditions to measure respiration rhythm and its variability. The thermal camera on the other hand, although it can not be discarded directly, performed poorly if compared with the other two methods. Further studies are needed to con rm that these methods can be used in real life conditions.20192019-05-0120192019-03-21journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/130731https://dx.doi.org/10.1016/j.bspc.2019.02.004reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/1307312026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Comparison of video-based methods for respiration rhythm measurement |
| title |
Comparison of video-based methods for respiration rhythm measurement |
| spellingShingle |
Comparison of video-based methods for respiration rhythm measurement Mateu Mateus, Marc|||0000-0002-6849-7426 Respiration - Measurement Pulmonary function tests Respiració -- Mesurament Aparell respiratori -- Proves funcionals Àrees temàtiques de la UPC::Enginyeria biomèdica |
| title_short |
Comparison of video-based methods for respiration rhythm measurement |
| title_full |
Comparison of video-based methods for respiration rhythm measurement |
| title_fullStr |
Comparison of video-based methods for respiration rhythm measurement |
| title_full_unstemmed |
Comparison of video-based methods for respiration rhythm measurement |
| title_sort |
Comparison of video-based methods for respiration rhythm measurement |
| dc.creator.none.fl_str_mv |
Mateu Mateus, Marc|||0000-0002-6849-7426 Guede Fernández, Federico|||0000-0003-2762-0333 Ferrer Mileo, Víctor García González, Miguel Ángel|||0000-0002-8043-4794 Ramos Castro, Juan José|||0000-0001-9413-2001 Fernández Chimeno, Mireya|||0000-0001-8384-1320 |
| author |
Mateu Mateus, Marc|||0000-0002-6849-7426 |
| author_facet |
Mateu Mateus, Marc|||0000-0002-6849-7426 Guede Fernández, Federico|||0000-0003-2762-0333 Ferrer Mileo, Víctor García González, Miguel Ángel|||0000-0002-8043-4794 Ramos Castro, Juan José|||0000-0001-9413-2001 Fernández Chimeno, Mireya|||0000-0001-8384-1320 |
| author_role |
author |
| author2 |
Guede Fernández, Federico|||0000-0003-2762-0333 Ferrer Mileo, Víctor García González, Miguel Ángel|||0000-0002-8043-4794 Ramos Castro, Juan José|||0000-0001-9413-2001 Fernández Chimeno, Mireya|||0000-0001-8384-1320 |
| author2_role |
author author author author author |
| dc.subject.none.fl_str_mv |
Respiration - Measurement Pulmonary function tests Respiració -- Mesurament Aparell respiratori -- Proves funcionals Àrees temàtiques de la UPC::Enginyeria biomèdica |
| topic |
Respiration - Measurement Pulmonary function tests Respiració -- Mesurament Aparell respiratori -- Proves funcionals Àrees temàtiques de la UPC::Enginyeria biomèdica |
| description |
The aim of this work is to characterize the di erences in the respiratory rhythm obtained through three video based methods by comparing the obtained respiratory signals with the one obtained with the gold standard method in adult population. The analysed methods are an RGB camera, a depth camera and a thermal camera while the gold standard is an inductive thorax plethysmography system (Respiband system from BioSignals Plux). 21 healthy subjects where measured, performing 4 tests for each subject. The respiratory rhythm and its variability was obtained from the four respiratory signals (3 video methods and gold standard). The signal acquisition was performed with custom and proprietary algorithms. To characterize the respiratory rhythm and its variability obtained with the di erent video sources and gold standard, the instantaneous frequency, Bland-Altman plots and standard deviation of the error between video methods and the gold standard have been computed. The depth and RGB camera present high agreement with no statistical di erences between them, with errors when comparing with the gold standard in the range of mHz. The thermal camera performs poorly if compared with the two other methods, nevertheless it cannot be discarded directly because some errors produced by the subjects head movement could not be corrected. From these results we conclude that the depth and RGB camera, and their respective acquisition algorithms) can be used in controlled conditions to measure respiration rhythm and its variability. The thermal camera on the other hand, although it can not be discarded directly, performed poorly if compared with the other two methods. Further studies are needed to con rm that these methods can be used in real life conditions. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019 2019-05-01 2019 2019-03-21 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 AM http://purl.org/coar/version/c_ab4af688f83e57aa |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/130731 https://dx.doi.org/10.1016/j.bspc.2019.02.004 |
| url |
https://hdl.handle.net/2117/130731 https://dx.doi.org/10.1016/j.bspc.2019.02.004 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869421691605614592 |
| score |
15,301603 |