Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization
The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor's impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue desi...
| Autores: | , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2017 |
| País: | España |
| Institución: | Universidad de Barcelona |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:diposit.ub.edu:2445/152689 |
| Acceso en línea: | https://hdl.handle.net/2445/152689 |
| Access Level: | acceso abierto |
| Palabra clave: | Espectroscòpia d'impedància Insuficiència cardíaca Bioelectrònica Amplificadors (Electrònica) Impedance spectroscopy Heart failure Bioelectronics Amplifiers (Electronics) |
| id |
ES_da8bcb13ca10f2590b7ce3ca69aa3f0b |
|---|---|
| oai_identifier_str |
oai:diposit.ub.edu:2445/152689 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturizationPruna Morales, RaquelPalacio Bonet, FranciscoBaraket, AbdoullatifBausells, JoanErrachid, AbdelhamidLópez de Miguel, ManuelEspectroscòpia d'impedànciaInsuficiència cardíacaBioelectrònicaAmplificadors (Electrònica)Impedance spectroscopyHeart failureBioelectronicsAmplifiers (Electronics)The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor's impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue design coupled to a digital filter based on a lock-in amplifier as an alternative to complex architectures reported hitherto. A low-cost, miniaturized and fully integrated acquisition electronic system was developed, tested for a fully integrated three-lead electrochemical biosensor and benchmarked against a commercial potentiostat. The portable potentiostat was coupled to an array of miniaturized gold working electrodes to perform complex impedance analyses for tumor necrosis factor α (TNF-α) cytokine detection. This wearable potentiostat is very promising for the development of low-cost point-of-care (POC) with low power consumption.MDPI2017info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/152689Articles publicats en revistes (Enginyeria Electrònica i Biomèdica)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: https://doi.org/10.3390/proceedings1040604MDPI Proceedings, 2017, vol. 1, num. 4, p. 604https://doi.org/10.3390/proceedings1040604info:eu-repo/grantAgreement/EC/FP7/614168info:eu-repo/grantAgreement/EC/H2020/643694cc-by (c) Pruna Morales, Raquel et al., 2017http://creativecommons.org/licenses/by/3.0/esinfo:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/1526892026-05-27T06:46:51Z |
| dc.title.none.fl_str_mv |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization |
| title |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization |
| spellingShingle |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization Pruna Morales, Raquel Espectroscòpia d'impedància Insuficiència cardíaca Bioelectrònica Amplificadors (Electrònica) Impedance spectroscopy Heart failure Bioelectronics Amplifiers (Electronics) |
| title_short |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization |
| title_full |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization |
| title_fullStr |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization |
| title_full_unstemmed |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization |
| title_sort |
Low-cost impedance measurements for lab-on-a-chip architectures: Towards potentiostat miniaturization |
| dc.creator.none.fl_str_mv |
Pruna Morales, Raquel Palacio Bonet, Francisco Baraket, Abdoullatif Bausells, Joan Errachid, Abdelhamid López de Miguel, Manuel |
| author |
Pruna Morales, Raquel |
| author_facet |
Pruna Morales, Raquel Palacio Bonet, Francisco Baraket, Abdoullatif Bausells, Joan Errachid, Abdelhamid López de Miguel, Manuel |
| author_role |
author |
| author2 |
Palacio Bonet, Francisco Baraket, Abdoullatif Bausells, Joan Errachid, Abdelhamid López de Miguel, Manuel |
| author2_role |
author author author author author |
| dc.subject.none.fl_str_mv |
Espectroscòpia d'impedància Insuficiència cardíaca Bioelectrònica Amplificadors (Electrònica) Impedance spectroscopy Heart failure Bioelectronics Amplifiers (Electronics) |
| topic |
Espectroscòpia d'impedància Insuficiència cardíaca Bioelectrònica Amplificadors (Electrònica) Impedance spectroscopy Heart failure Bioelectronics Amplifiers (Electronics) |
| description |
The development of miniaturized potentiostats capable of measuring in a wide range of conditions and with full characteristics (e.g., wide bandwidth and capacitive/inductive contribution to sensor's impedance) is still an unresolved challenge in bioelectronics. We present a simple analogue design coupled to a digital filter based on a lock-in amplifier as an alternative to complex architectures reported hitherto. A low-cost, miniaturized and fully integrated acquisition electronic system was developed, tested for a fully integrated three-lead electrochemical biosensor and benchmarked against a commercial potentiostat. The portable potentiostat was coupled to an array of miniaturized gold working electrodes to perform complex impedance analyses for tumor necrosis factor α (TNF-α) cytokine detection. This wearable potentiostat is very promising for the development of low-cost point-of-care (POC) with low power consumption. |
| publishDate |
2017 |
| dc.date.none.fl_str_mv |
2017 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/152689 |
| url |
https://hdl.handle.net/2445/152689 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Reproducció del document publicat a: https://doi.org/10.3390/proceedings1040604 MDPI Proceedings, 2017, vol. 1, num. 4, p. 604 https://doi.org/10.3390/proceedings1040604 info:eu-repo/grantAgreement/EC/FP7/614168 info:eu-repo/grantAgreement/EC/H2020/643694 |
| dc.rights.none.fl_str_mv |
cc-by (c) Pruna Morales, Raquel et al., 2017 http://creativecommons.org/licenses/by/3.0/es info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
cc-by (c) Pruna Morales, Raquel et al., 2017 http://creativecommons.org/licenses/by/3.0/es |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Enginyeria Electrònica i Biomèdica) reponame:Dipòsit Digital de la UB instname:Universidad de Barcelona |
| instname_str |
Universidad de Barcelona |
| reponame_str |
Dipòsit Digital de la UB |
| collection |
Dipòsit Digital de la UB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869421588439367680 |
| score |
15,301629 |