Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure
Heart failure (HF) is a complex syndrome in which the heart is unable to pump enough blood containing oxygen and nutrients to meet the body's demands. HF is the leading cause of hospitalization for patients over 65 years of age. After a patient is diagnosed with HF, the mortality rate is 50% wi...
| Autores: | , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión aceptada para publicación |
| Fecha de publicación: | 2023 |
| País: | España |
| Institución: | Universidad de Sevilla (US) |
| Repositorio: | idUS. Depósito de Investigación de la Universidad de Sevilla |
| OAI Identifier: | oai:idus.us.es:11441/166948 |
| Acceso en línea: | https://hdl.handle.net/11441/166948 https://doi.org/10.1109/tim.2023.3273662 |
| Access Level: | acceso abierto |
| Palabra clave: | Bioimpedance (BI) Biomedical sensor Electrodes Electronics design Heart failure (HF) Real-time monitoring Wearable |
| id |
ES_da2d2d4e8c47d35818f7a6a32a72005a |
|---|---|
| oai_identifier_str |
oai:idus.us.es:11441/166948 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart FailureScagliusi, Santiago Joaquín F.Giménez Miranda, LuisPérez García, PabloMartín Fernández, DanielMedrano Ortega, Francisco JavierHuertas Sánchez, GloriaYúfera García, AlbertoBioimpedance (BI)Biomedical sensorElectrodesElectronics designHeart failure (HF)Real-time monitoringWearableHeart failure (HF) is a complex syndrome in which the heart is unable to pump enough blood containing oxygen and nutrients to meet the body's demands. HF is the leading cause of hospitalization for patients over 65 years of age. After a patient is diagnosed with HF, the mortality rate is 50% within the first five years. Presently, there are no unanimous diagnostic criteria for HF. Bioimpedance (BI) analysis has been proposed in recent years as a technique to detect one of the main symptoms: changes in body volume due to edema. This research presents a portable device (Volum), capable of performing real-time BI measurements in a low-cost and noninvasive way. The goal is to improve patient monitoring at home to ensure rapid intervention in cases of worsening conditions, either with timely hospitalizations or adjustments to a patient's usual treatment. Volum is a small, wearable, wireless, lightweight, low-power clinical pilot prototype that takes measurements through four electrodes and sends the data via Bluetooth to an Android device.Ministerio de Ciencia, Innovación y Universidades RTI2018-093512-B-C21Instituto de Salud Carlos III DTS19/00134, DTS19/00137Institute of Electrical and Electronics EngineersTecnología ElectrónicaMedicinaElectrónica y ElectromagnetismoBiología CelularMinisterio de Ciencia, Innovación y Universidades (MICINN). EspañaInstituto de Salud Carlos III2023info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionapplication/pdfapplication/pdfhttps://hdl.handle.net/11441/166948https://doi.org/10.1109/tim.2023.3273662reponame:idUS. Depósito de Investigación de la Universidad de Sevillainstname:Universidad de Sevilla (US)InglésIEEE Transactions on Instrumentation and Measurement, 72, 4006608.RTI2018-093512-B-C21DTS19/00134DTS19/00137https://doi.org/10.1109/tim.2023.3273662info:eu-repo/semantics/openAccessoai:idus.us.es:11441/1669482026-06-17T12:51:07Z |
| dc.title.none.fl_str_mv |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure |
| title |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure |
| spellingShingle |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure Scagliusi, Santiago Joaquín F. Bioimpedance (BI) Biomedical sensor Electrodes Electronics design Heart failure (HF) Real-time monitoring Wearable |
| title_short |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure |
| title_full |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure |
| title_fullStr |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure |
| title_full_unstemmed |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure |
| title_sort |
Bioimpedance Spectroscopy-Based Edema Supervision Wearable System for Noninvasive Monitoring of Heart Failure |
| dc.creator.none.fl_str_mv |
Scagliusi, Santiago Joaquín F. Giménez Miranda, Luis Pérez García, Pablo Martín Fernández, Daniel Medrano Ortega, Francisco Javier Huertas Sánchez, Gloria Yúfera García, Alberto |
| author |
Scagliusi, Santiago Joaquín F. |
| author_facet |
Scagliusi, Santiago Joaquín F. Giménez Miranda, Luis Pérez García, Pablo Martín Fernández, Daniel Medrano Ortega, Francisco Javier Huertas Sánchez, Gloria Yúfera García, Alberto |
| author_role |
author |
| author2 |
Giménez Miranda, Luis Pérez García, Pablo Martín Fernández, Daniel Medrano Ortega, Francisco Javier Huertas Sánchez, Gloria Yúfera García, Alberto |
| author2_role |
author author author author author author |
| dc.contributor.none.fl_str_mv |
Tecnología Electrónica Medicina Electrónica y Electromagnetismo Biología Celular Ministerio de Ciencia, Innovación y Universidades (MICINN). España Instituto de Salud Carlos III |
| dc.subject.none.fl_str_mv |
Bioimpedance (BI) Biomedical sensor Electrodes Electronics design Heart failure (HF) Real-time monitoring Wearable |
| topic |
Bioimpedance (BI) Biomedical sensor Electrodes Electronics design Heart failure (HF) Real-time monitoring Wearable |
| description |
Heart failure (HF) is a complex syndrome in which the heart is unable to pump enough blood containing oxygen and nutrients to meet the body's demands. HF is the leading cause of hospitalization for patients over 65 years of age. After a patient is diagnosed with HF, the mortality rate is 50% within the first five years. Presently, there are no unanimous diagnostic criteria for HF. Bioimpedance (BI) analysis has been proposed in recent years as a technique to detect one of the main symptoms: changes in body volume due to edema. This research presents a portable device (Volum), capable of performing real-time BI measurements in a low-cost and noninvasive way. The goal is to improve patient monitoring at home to ensure rapid intervention in cases of worsening conditions, either with timely hospitalizations or adjustments to a patient's usual treatment. Volum is a small, wearable, wireless, lightweight, low-power clinical pilot prototype that takes measurements through four electrodes and sends the data via Bluetooth to an Android device. |
| publishDate |
2023 |
| dc.date.none.fl_str_mv |
2023 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion |
| format |
article |
| status_str |
acceptedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/11441/166948 https://doi.org/10.1109/tim.2023.3273662 |
| url |
https://hdl.handle.net/11441/166948 https://doi.org/10.1109/tim.2023.3273662 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
IEEE Transactions on Instrumentation and Measurement, 72, 4006608. RTI2018-093512-B-C21 DTS19/00134 DTS19/00137 https://doi.org/10.1109/tim.2023.3273662 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Institute of Electrical and Electronics Engineers |
| publisher.none.fl_str_mv |
Institute of Electrical and Electronics Engineers |
| dc.source.none.fl_str_mv |
reponame:idUS. Depósito de Investigación de la Universidad de Sevilla instname:Universidad de Sevilla (US) |
| instname_str |
Universidad de Sevilla (US) |
| reponame_str |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| collection |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869421528850890752 |
| score |
15.811543 |