Alkalinity determination by potentiometry: intercalibration using three different methods
16 pages, 1 figure, 3 tables.
| Authors: | , , , , |
|---|---|
| Format: | article |
| Status: | Published version |
| Publication Date: | 2000 |
| Country: | España |
| Institution: | Consejo Superior de Investigaciones Científicas (CSIC) |
| Repository: | DIGITAL.CSIC. Repositorio Institucional del CSIC |
| OAI Identifier: | oai:digital.csic.es:10261/25136 |
| Online Access: | http://hdl.handle.net/10261/25136 |
| Access Level: | Open access |
| Keyword: | Alkalinity Potentiometry Seawater Certified reference materials Alcalinidad Potenciometría Agua de mar Material certificado de referencia |
| id |
ES_d7bbeb8680dd6b62300314c2ccbfb5f6 |
|---|---|
| oai_identifier_str |
oai:digital.csic.es:10261/25136 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Alkalinity determination by potentiometry: intercalibration using three different methodsDeterminación potenciométrica de la alcalinidad: Intercalibración usando tres métodos diferentesMintrop, LudgerPérez, Fiz F.González-Dávila, MelchorSantana-Casiano, Juana MagdalenaKörtzinger, ArneAlkalinityPotentiometrySeawaterCertified reference materialsAlcalinidadPotenciometríaAgua de marMaterial certificado de referencia16 pages, 1 figure, 3 tables.[EN] Seawater was sampled from different depths in the North Atlantic Ocean (Canary Islands region) and distributed among three different labs for the determination of titration alkalinity. Analysis was performed by potentiometric methods, involving titration in a closed cell, titration in an open cell and a two end-point acid addition method. The precision, which is the sample reproducibility taken from the mean standard deviation for replicate measurements, was between 0.45 and 0.90 µmol kg(-1) for the individual labs. Accuracy, here taken as the deviation for the values of a lab from the mean of all three, was mostly below 1 µmol kg(-1) and never exceeded 0.1% of the sample value. Mean standard deviation for all labs and all samples was 0.87 µmol kg(-1), once the individual methods were calibrated using certified reference material (CRM). Without CRM calibration, the mean standard deviation would increase to 2.8 µmol k(-1). The conclusion is that current high precision methods for alkalinity measurements calibrated with CRMs are able to reach similar accuracy as the measurement of total dissolved inorganic carbon by coulometry and therefore allow for the precise determination of the oceanic carbon dioxide system by using the two measured parameters.[ES] Se determinó la alcalinidad de muestras de agua de mar recogidas a diferentes profundidades en el Océano Atlántico Norte y distribuidas entre tres laboratorios, utilizando tres variantes potenciométricas: valoración en cubeta cerrada, valoración en cubeta abierta y un método de adición a doble punto final. La precisión, la reproducibilidad de la muestra obtenida a partir de la desviación estándar media para medidas replicadas, fue entre 0.45 y 0.90 µmol. kg(-1) para cada laboratorio. La exactitud, tomada como la desviación de los valores de un laboratorio respecto de la media de los tres, fue mayoritariamente menor que 1 µmol. kg(-1) y nunca excedió 0.1% del valor de la muestra. La desviación media estándar para todos los laboratorios y todas las muestras fue de 0.87 µmol. kg(-1), una vez que los métodos individuales se calibraron usando material certificado de referencia (CRM). Sin la calibración con CRM, la desviación estándar media se incrementaría a 2.8 µmol. kg(-1). Se concluye que la precisión real de los métodos para la medida de la alcalinidad calibrada con CRM es capaz de alcanzar exactitudes similares a las medidas de carbono inorgánico total por coulometría y por lo tanto permite la determinación precisa del sistema de carbono oceánico usando la medida de las dos variables.This work was funded by the European Community under grant MAS3-CT96-0060.Peer reviewedUniversidad Autónoma de Baja CaliforniaEuropean CommissionConsejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]201020102000info:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_6501Publisher's versioninfo:eu-repo/semantics/publishedVersion146001 bytesapplication/pdfhttp://hdl.handle.net/10261/25136reponame:DIGITAL.CSIC. Repositorio Institucional del CSICinstname:Consejo Superior de Investigaciones Científicas (CSIC)EspañolIngléshttp://www.cienciasmarinas.com/index.php/cmarinas/article/view/573Síinfo:eu-repo/semantics/openAccessoai:digital.csic.es:10261/251362026-05-22T06:33:51Z |
| dc.title.none.fl_str_mv |
Alkalinity determination by potentiometry: intercalibration using three different methods Determinación potenciométrica de la alcalinidad: Intercalibración usando tres métodos diferentes |
| title |
Alkalinity determination by potentiometry: intercalibration using three different methods |
| spellingShingle |
Alkalinity determination by potentiometry: intercalibration using three different methods Mintrop, Ludger Alkalinity Potentiometry Seawater Certified reference materials Alcalinidad Potenciometría Agua de mar Material certificado de referencia |
| title_short |
Alkalinity determination by potentiometry: intercalibration using three different methods |
| title_full |
Alkalinity determination by potentiometry: intercalibration using three different methods |
| title_fullStr |
Alkalinity determination by potentiometry: intercalibration using three different methods |
| title_full_unstemmed |
Alkalinity determination by potentiometry: intercalibration using three different methods |
| title_sort |
Alkalinity determination by potentiometry: intercalibration using three different methods |
| dc.creator.none.fl_str_mv |
Mintrop, Ludger Pérez, Fiz F. González-Dávila, Melchor Santana-Casiano, Juana Magdalena Körtzinger, Arne |
| author |
Mintrop, Ludger |
| author_facet |
Mintrop, Ludger Pérez, Fiz F. González-Dávila, Melchor Santana-Casiano, Juana Magdalena Körtzinger, Arne |
| author_role |
author |
| author2 |
Pérez, Fiz F. González-Dávila, Melchor Santana-Casiano, Juana Magdalena Körtzinger, Arne |
| author2_role |
author author author author |
| dc.contributor.none.fl_str_mv |
European Commission Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72] |
| dc.subject.none.fl_str_mv |
Alkalinity Potentiometry Seawater Certified reference materials Alcalinidad Potenciometría Agua de mar Material certificado de referencia |
| topic |
Alkalinity Potentiometry Seawater Certified reference materials Alcalinidad Potenciometría Agua de mar Material certificado de referencia |
| description |
16 pages, 1 figure, 3 tables. |
| publishDate |
2000 |
| dc.date.none.fl_str_mv |
2000 2010 2010 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article http://purl.org/coar/resource_type/c_6501 Publisher's version info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10261/25136 |
| url |
http://hdl.handle.net/10261/25136 |
| dc.language.none.fl_str_mv |
Español Inglés |
| language_invalid_str_mv |
Español Inglés |
| dc.relation.none.fl_str_mv |
http://www.cienciasmarinas.com/index.php/cmarinas/article/view/573 Sí |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
146001 bytes application/pdf |
| dc.publisher.none.fl_str_mv |
Universidad Autónoma de Baja California |
| publisher.none.fl_str_mv |
Universidad Autónoma de Baja California |
| dc.source.none.fl_str_mv |
reponame:DIGITAL.CSIC. Repositorio Institucional del CSIC instname:Consejo Superior de Investigaciones Científicas (CSIC) |
| instname_str |
Consejo Superior de Investigaciones Científicas (CSIC) |
| reponame_str |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| collection |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869421033269755904 |
| score |
15.812429 |