Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices
[EN] The characterization of a PET detector head based on continuous LYSO crystals and silicon photomultiplier (SiPM) arrays as photodetectors has been carried out for its use in the development of a small animal PET prototype. The detector heads are composed of a continuous crystal and a SiPM matri...
| Autores: | , , , , , , , , , |
|---|---|
| Formato: | artículo |
| Fecha de publicación: | 2010 |
| País: | España |
| Recursos: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/232838 |
| Acesso em linha: | https://riunet.upv.es/handle/10251/232838 |
| Access Level: | acceso abierto |
| Palavra-chave: | Positron emission tomography LYSO crystals Silicon photomultipliers Small animal PET Spatial resolution Position reconstruction |
| id |
ES_d7af2cb679ea641f19615b6d3a99276c |
|---|---|
| oai_identifier_str |
oai:riunet.upv.es:10251/232838 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matricesLlosá, G.Lacasta, C.Bisogni, M. G.Del Guerra, A.Marcatili, S.Barrillon, P.Bondil-Blin, S.de la Taille, C.Piemonte, C.Barrio-Toala, John|||0000-0001-5181-2146Positron emission tomographyLYSO crystalsSilicon photomultipliersSmall animal PETSpatial resolutionPosition reconstruction[EN] The characterization of a PET detector head based on continuous LYSO crystals and silicon photomultiplier (SiPM) arrays as photodetectors has been carried out for its use in the development of a small animal PET prototype. The detector heads are composed of a continuous crystal and a SiPM matrix with 64 pixels in a common substrate, fabricated specifically for this project. Three crystals of 12 mm x 12 mm x 5 mm size with different types of painting have been tested: white, black and black on the sides but white on the back of the crystal. The best energy resolution, obtained with the white crystal, is 16% FWHM. The detector response is linear up to 1275 keV. Tests with different position determination algorithms have been carried out with the three crystals. The spatial resolution obtained with the center of gravity algorithm is around 0.9 mm FWHM for the three crystals. As expected, the use of this algorithm results in the displacement of the reconstructed position toward the center of the crystal, more pronounced in the case of the white crystal. A maximum likelihood algorithm has been tested that can reconstruct correctly the interaction position of the photons also in the case of the white crystal.This work is partially supported by the European Commission's Seventh Framework Programme through a Marie Curie Reintegration Grant.IOP PublishingDepartamento de Ingeniería ElectrónicaEscuela Técnica Superior de Ingeniería de TelecomunicaciónEuropean CommissionRepositorio Institucional de la Universitat Politècnica de València Riunet20102010-12-07journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfapplication/pdfhttps://riunet.upv.es/handle/10251/232838reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) http://creativecommons.org/licenses/by-nc-nd/4.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/2328382026-06-13T07:49:27Z |
| dc.title.none.fl_str_mv |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices |
| title |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices |
| spellingShingle |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices Llosá, G. Positron emission tomography LYSO crystals Silicon photomultipliers Small animal PET Spatial resolution Position reconstruction |
| title_short |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices |
| title_full |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices |
| title_fullStr |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices |
| title_full_unstemmed |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices |
| title_sort |
Characterization of a PET detector head based on continuous LYSO crystals and monolithic, 64-pixel silicon photomultiplier matrices |
| dc.creator.none.fl_str_mv |
Llosá, G. Lacasta, C. Bisogni, M. G. Del Guerra, A. Marcatili, S. Barrillon, P. Bondil-Blin, S. de la Taille, C. Piemonte, C. Barrio-Toala, John|||0000-0001-5181-2146 |
| author |
Llosá, G. |
| author_facet |
Llosá, G. Lacasta, C. Bisogni, M. G. Del Guerra, A. Marcatili, S. Barrillon, P. Bondil-Blin, S. de la Taille, C. Piemonte, C. Barrio-Toala, John|||0000-0001-5181-2146 |
| author_role |
author |
| author2 |
Lacasta, C. Bisogni, M. G. Del Guerra, A. Marcatili, S. Barrillon, P. Bondil-Blin, S. de la Taille, C. Piemonte, C. Barrio-Toala, John|||0000-0001-5181-2146 |
| author2_role |
author author author author author author author author author |
| dc.contributor.none.fl_str_mv |
Departamento de Ingeniería Electrónica Escuela Técnica Superior de Ingeniería de Telecomunicación European Commission Repositorio Institucional de la Universitat Politècnica de València Riunet |
| dc.subject.none.fl_str_mv |
Positron emission tomography LYSO crystals Silicon photomultipliers Small animal PET Spatial resolution Position reconstruction |
| topic |
Positron emission tomography LYSO crystals Silicon photomultipliers Small animal PET Spatial resolution Position reconstruction |
| description |
[EN] The characterization of a PET detector head based on continuous LYSO crystals and silicon photomultiplier (SiPM) arrays as photodetectors has been carried out for its use in the development of a small animal PET prototype. The detector heads are composed of a continuous crystal and a SiPM matrix with 64 pixels in a common substrate, fabricated specifically for this project. Three crystals of 12 mm x 12 mm x 5 mm size with different types of painting have been tested: white, black and black on the sides but white on the back of the crystal. The best energy resolution, obtained with the white crystal, is 16% FWHM. The detector response is linear up to 1275 keV. Tests with different position determination algorithms have been carried out with the three crystals. The spatial resolution obtained with the center of gravity algorithm is around 0.9 mm FWHM for the three crystals. As expected, the use of this algorithm results in the displacement of the reconstructed position toward the center of the crystal, more pronounced in the case of the white crystal. A maximum likelihood algorithm has been tested that can reconstruct correctly the interaction position of the photons also in the case of the white crystal. |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010 2010-12-07 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://riunet.upv.es/handle/10251/232838 |
| url |
https://riunet.upv.es/handle/10251/232838 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reconocimiento - No comercial - Sin obra derivada (by-nc-nd) http://creativecommons.org/licenses/by-nc-nd/4.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
IOP Publishing |
| publisher.none.fl_str_mv |
IOP Publishing |
| dc.source.none.fl_str_mv |
reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia instname:Universitat Politècnica de València (UPV) |
| instname_str |
Universitat Politècnica de València (UPV) |
| reponame_str |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| collection |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869421028145364992 |
| score |
15,198674 |