Combining OPM and lesion mapping data for epilepsy surgery planning: a simulation study

When planning for epilepsy surgery, multiple potential sites for resection may be identified through anatomical imaging. Magnetoencephalography (MEG) using optically pumped sensors (OP-MEG) is a non-invasive functional neuroimaging technique which could be used to help identify the epileptogenic zon...

ver descrição completa

Detalhes bibliográficos
Autores: The MELD Project Consortium, Bargalló Alabart, Núria, Pascual-Diaz, Saül, González Ortiz, Sofía, Conde Blanco, Estefanía, Pariente, Jose Carlos
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2024
País:España
Recursos:Universidad de Barcelona
Repositorio:Dipòsit Digital de la UB
OAI Identifier:oai:diposit.ub.edu:2445/221510
Acesso em linha:https://hdl.handle.net/2445/221510
Access Level:acceso abierto
Palavra-chave:Simulació (Ciències de la salut)
Cirurgia
Epilèpsia
Malingering
Surgery
Epilepsy
Descrição
Resumo:When planning for epilepsy surgery, multiple potential sites for resection may be identified through anatomical imaging. Magnetoencephalography (MEG) using optically pumped sensors (OP-MEG) is a non-invasive functional neuroimaging technique which could be used to help identify the epileptogenic zone from these candidate regions. Here we test the utility of a-priori information from anatomical imaging for differentiating potential lesion sites with OP-MEG. We investigate a number of scenarios: whether to use rigid or flexible sensor arrays, with or without a-priori source information and with or without source modelling errors. We simulated OP-MEG recordings for 1309 potential lesion sites identified from anatomical images in the Multi-centre Epilepsy Lesion Detection (MELD) project. To localise the simulated data, we used three source inversion schemes: unconstrained, prior source locations at centre of the candidate sites, and prior source locations within a volume around the lesion location. We found that prior knowledge of the candidate lesion zones made the inversion robust to errors in sensor gain, orientation and even location. When the reconstruction was too highly restricted and the source assumptions were inaccurate, the utility of this a-priori information was undermined. Overall, we found that constraining the reconstruction to the region including and around the participant's potential lesion sites provided the best compromise of robustness against modelling or measurement error.