Determination of polyphenolic profiles by liquid chromatography-electrospray-tandem mass spectrometry for the authentication of fruit extracts

Liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS) was applied to the analysis and authentication of fruit-based products and fruit-based pharmaceutical preparations. A Kinetex C18 reversed-phase column under gradient elution with 0.1 % formic acid aqueous solution and methan...

Descripción completa

Detalles Bibliográficos
Autores: Puigventós, Lídia, Navarro Reig, Meritxell, Alechaga Silva, Élida, Núñez Burcio, Oscar, Saurina, Javier, Hernández Cassou, Santiago, Puignou i Garcia, Lluís
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2014
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:2445/99481
Acceso en línea:https://hdl.handle.net/2445/99481
Access Level:acceso abierto
Palabra clave:Polifenols
Productes naturals
Química dels aliments
Cromatografia de líquids
Espectrometria de masses
Polyphenols
Natural products
Food composition
Liquid chromatography
Mass spectrometry
Descripción
Sumario:Liquid chromatography-electrospray-tandem mass spectrometry (LC-ESI-MS/MS) was applied to the analysis and authentication of fruit-based products and fruit-based pharmaceutical preparations. A Kinetex C18 reversed-phase column under gradient elution with 0.1 % formic acid aqueous solution and methanol mobile phases was used for the simultaneous determination of 26 polyphenols, allowing an acceptable separation in less than 22 min. Instrumental quality parameters such as limits of detection (LOD, values between 12-14 µg/L for 19 of the 26 analyzed polyphenols), linearity (r2 > 0.991), run-to-run and day-to-day precisions (RSD values lower than 9.9 and 13.5 %, respectively), and accuracy (relative errors lower than 8 %) were established. A simple extraction method, consisting of a sample sonication with acetone:water:hydrochloric acid (70:29.9:0.1 v/v/v) and centrifugation, was proposed. Two calibration procedures, external calibration using standards prepared in water and standard addition, were evaluated for polyphenol quantification in several grape and cranberry fruits and processed fruit products. For a 95 % confidence level, no statistical differences were observed between the two calibration methods (p values between 0.06 and 0.95), denoting that external calibration was suitable enough for the quantitative analysis of polyphenols in fruit-based products. The proposed LC-ESI-MS/MS method was then applied to the analysis of polyphenols in 23 grape-based and cranberry-based natural products and pharmaceutical preparations. Polyphenolic concentration data was then analyzed by principal component analysis (PCA) to extract information of the most significant profile data contributing to authentication of natural extracts according to their fruit of origin.