Impact of the wood combustion in an open fireplace on the air quality of a living room: Estimation of the respirable fraction

[EN] Presently, both in rural areas and in cities open fireplaces are still present and large quantities of wood are combusted every year. The present study aims to characterize aerosol size distribution, chemical composition and deposition in the human respiratory tract of particles emitted during...

Descripción completa

Detalles Bibliográficos
Autores: Castro Izquierdo, Amaya, Calvo Gordaliza, Ana Isabel, Blanco Alegre, Carlos del, Oduber Pérez, Fernanda Isabel, Alves, Célia dos Anjos, Coz Diego, Esther, Amato, Fulvio, Querol Carceller, Xavier, Fraile Laiz, Roberto
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2018
País:España
Institución:Universidad de León
Repositorio:BULERIA. Repositorio Institucional de la Universidad de León
OAI Identifier:oai:buleria.unileon.es:10612/26108
Acceso en línea:https://www.sciencedirect.com/science/article/pii/S0048969718303875
https://hdl.handle.net/10612/26108
Access Level:acceso abierto
Palabra clave:Física
Química
Aerosol size distribution
Alveolar fraction
Indoor air quality
Open fireplace
Wood combustion
3308.04 Ingeniería de la Contaminación
2210 Química Física
Descripción
Sumario:[EN] Presently, both in rural areas and in cities open fireplaces are still present and large quantities of wood are combusted every year. The present study aims to characterize aerosol size distribution, chemical composition and deposition in the human respiratory tract of particles emitted during the combustion of logs of oak in an open fireplace installed in the living room of a typical village house. CO2 and CO levels and aerosol size distribution have been continuously monitored and a PM10 sampler with two types of filters for chemical and microscopic analysis was also installed. The increment, between the operating periods and the indoor background, in the organic carbon and PM10 concentration due to the use of the fireplace is 15.7 ± 0.6 (mean ± standard deviation) and 58.5 ± 6.2 μg m−3, respectively. The two main polluting processes during the operation of the fireplace are the ignition with the subsequent refueling and the final cleaning of the residual ashes. In both phases mean values around 1800 particles cm−3 with CMD of 0.15 μm were measured. However, while PM10 levels of 130 ± 120 μg m−3 were estimated for the ignition stage, values of 200 ± 200 μg m−3 were obtained during the final cleaning step. Assessment conducted according to ISO standard 7708:1995, demonstrated that a person who stays in a living room when an open fireplace is lit will inhale, on average, 217 μg m−3 and 283 μg m−3 during the ignition and the refueling stages, respectively. Subsequent refueling proved to be much less polluting. The ashes removal can also be very polluting and dangerous to health if there are hidden small incandescent embers among the ashes (estimated PM10 of 132 μg m−3), reaching a CO2 level of 1940 ppm and a dangerous level of CO of 132 ppm