Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies
Peri-implant diseases are one of the main complications of dental implants. There are no well-established guidelines regarding laser parameters for implant decontamination. The aim was to compare two different settings of irradiation of the Er,Cr:YSGG laser on dental implants regarding surface alter...
| Authors: | , , , , |
|---|---|
| Format: | article |
| Status: | Published version |
| Publication Date: | 2020 |
| Country: | España |
| Institution: | Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| Repository: | Recercat. Dipósit de la Recerca de Catalunya |
| OAI Identifier: | oai:recercat.cat:2445/173596 |
| Online Access: | https://hdl.handle.net/2445/173596 |
| Access Level: | Open access |
| Keyword: | Làsers Implants dentals Mucosa oral Lasers Dental implants Oral mucosa |
| id |
ES_d60e67f5cbd9b6c2a642197bbd02c7f6 |
|---|---|
| oai_identifier_str |
oai:recercat.cat:2445/173596 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energiesChegeni, EhsanEspaña Tost, A. J. (Antonio Jesús)Barbosa de Figueiredo, Rui PedroValmaseda Castellón, EduardoArnabat Domínguez, JosepLàsersImplants dentalsMucosa oralLasersDental implantsOral mucosaPeri-implant diseases are one of the main complications of dental implants. There are no well-established guidelines regarding laser parameters for implant decontamination. The aim was to compare two different settings of irradiation of the Er,Cr:YSGG laser on dental implants regarding surface alterations and determine the best settings for less damage on the surface. An in vitro study was performed and 30 areas of dental implants were irradiated with two different regimes of energy per pulse 50 and 84 mJ (1.5 W/30 Hz and 2.5 W/30 Hz). A total of 30 sites of implants were irradiated with three different tips (10 surfaces per tip): conical (RTF3-17 mm), side firing (SFT8-18 mm) and cylindrical (MGG6-6 mm). The following descriptive classification on surface damage was employed: no damage (class A), minimal effects (class B), metal fall with melting (class C), and destruction with carbonization (class D). The assessment was made through a descriptive scanning electron microscope (SEM) analysis. Side firing and conical tips at 50 mJ were classified as class A. Side firing at 84 mJ and cylindrical tips 50 mJ and 84 mJ were classified as class B. Finally, class C defects were found in the areas where the conical tip was used at 84 mJ. Side firing and conical tips at 50 mJ do not seem to damage the implant surface.MDPI2021202120202021info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion10 p.application/pdfhttps://hdl.handle.net/2445/173596Articles publicats en revistes (Odontoestomatologia)reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésReproducció del document publicat a: https://doi.org/10.3390/dj8040109Dentistry Journal (MDPI), 2020, vol. 8, num. 4, p. 109-118https://doi.org/10.3390/dj8040109cc-by (c) Chegeni, Ehsan et al., 2020http://creativecommons.org/licenses/by/3.0/esinfo:eu-repo/semantics/openAccessoai:recercat.cat:2445/1735962026-05-29T05:05:01Z |
| dc.title.none.fl_str_mv |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies |
| title |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies |
| spellingShingle |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies Chegeni, Ehsan Làsers Implants dentals Mucosa oral Lasers Dental implants Oral mucosa |
| title_short |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies |
| title_full |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies |
| title_fullStr |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies |
| title_full_unstemmed |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies |
| title_sort |
Effect of an Er,Cr:YSGG laser on the surface of implants: a descriptive comparative study of 3 different tips and pulse energies |
| dc.creator.none.fl_str_mv |
Chegeni, Ehsan España Tost, A. J. (Antonio Jesús) Barbosa de Figueiredo, Rui Pedro Valmaseda Castellón, Eduardo Arnabat Domínguez, Josep |
| author |
Chegeni, Ehsan |
| author_facet |
Chegeni, Ehsan España Tost, A. J. (Antonio Jesús) Barbosa de Figueiredo, Rui Pedro Valmaseda Castellón, Eduardo Arnabat Domínguez, Josep |
| author_role |
author |
| author2 |
España Tost, A. J. (Antonio Jesús) Barbosa de Figueiredo, Rui Pedro Valmaseda Castellón, Eduardo Arnabat Domínguez, Josep |
| author2_role |
author author author author |
| dc.subject.none.fl_str_mv |
Làsers Implants dentals Mucosa oral Lasers Dental implants Oral mucosa |
| topic |
Làsers Implants dentals Mucosa oral Lasers Dental implants Oral mucosa |
| description |
Peri-implant diseases are one of the main complications of dental implants. There are no well-established guidelines regarding laser parameters for implant decontamination. The aim was to compare two different settings of irradiation of the Er,Cr:YSGG laser on dental implants regarding surface alterations and determine the best settings for less damage on the surface. An in vitro study was performed and 30 areas of dental implants were irradiated with two different regimes of energy per pulse 50 and 84 mJ (1.5 W/30 Hz and 2.5 W/30 Hz). A total of 30 sites of implants were irradiated with three different tips (10 surfaces per tip): conical (RTF3-17 mm), side firing (SFT8-18 mm) and cylindrical (MGG6-6 mm). The following descriptive classification on surface damage was employed: no damage (class A), minimal effects (class B), metal fall with melting (class C), and destruction with carbonization (class D). The assessment was made through a descriptive scanning electron microscope (SEM) analysis. Side firing and conical tips at 50 mJ were classified as class A. Side firing at 84 mJ and cylindrical tips 50 mJ and 84 mJ were classified as class B. Finally, class C defects were found in the areas where the conical tip was used at 84 mJ. Side firing and conical tips at 50 mJ do not seem to damage the implant surface. |
| publishDate |
2020 |
| dc.date.none.fl_str_mv |
2020 2021 2021 2021 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/173596 |
| url |
https://hdl.handle.net/2445/173596 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Reproducció del document publicat a: https://doi.org/10.3390/dj8040109 Dentistry Journal (MDPI), 2020, vol. 8, num. 4, p. 109-118 https://doi.org/10.3390/dj8040109 |
| dc.rights.none.fl_str_mv |
cc-by (c) Chegeni, Ehsan et al., 2020 http://creativecommons.org/licenses/by/3.0/es info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
cc-by (c) Chegeni, Ehsan et al., 2020 http://creativecommons.org/licenses/by/3.0/es |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
10 p. application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI |
| publisher.none.fl_str_mv |
MDPI |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Odontoestomatologia) reponame:Recercat. Dipósit de la Recerca de Catalunya instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| instname_str |
Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya) |
| reponame_str |
Recercat. Dipósit de la Recerca de Catalunya |
| collection |
Recercat. Dipósit de la Recerca de Catalunya |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869420803270901760 |
| score |
15,812429 |