From target analysis to suspect and non-target screening of endocrine-disrupting compounds in human urine

[EN] In the present work, a target analysis method for simultaneously determining 24 diverse endocrine-disrupting compounds (EDCs) in urine (benzophenones, bisphenols, parabens, phthalates and antibacterials) was developed. The target analysis approach (including enzymatic hydrolysis, clean-up by so...

Descripción completa

Detalles Bibliográficos
Autores: Musatadi Larrucea, Mikel, Caballero, Claudia, Mijangos Treviño, Leire, Prieto Sobrino, Ailette, Olivares Zabalandicoechea, Maitane, Zuloaga Zubieta, Olatz
Tipo de recurso: artículo
Fecha de publicación:2022
País:España
Institución:Universidad del País Vasco
Repositorio:Addi. Archivo Digital para la Docencia y la Investigación
OAI Identifier:oai:addi.ehu.eus:10810/57486
Acceso en línea:http://hdl.handle.net/10810/57486
Access Level:acceso abierto
Palabra clave:endocrine-disrupting compounds
target analysis
liquid chromatography tandem mass spectrometry
suspect and non-target screening
high-resolution tandem mass spectrometry
Descripción
Sumario:[EN] In the present work, a target analysis method for simultaneously determining 24 diverse endocrine-disrupting compounds (EDCs) in urine (benzophenones, bisphenols, parabens, phthalates and antibacterials) was developed. The target analysis approach (including enzymatic hydrolysis, clean-up by solid-phase extraction and analysis by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS)) was optimized, validated and applied to volunteers' samples, in which 67% of the target EDCs were quantified. For instance, benzophenone-3 (0.2-13 ng g(-1)), bisphenol A (7.7-13.7 ng g(-1)), methyl 3,5-dihydroxybenzoate (8-254 ng g(-1)), mono butyl phthalate (2-17 ng g(-1)) and triclosan (0.3-9 ng g(-1)) were found at the highest concentrations, but the presence of other analogues was detected as well. The developed target method was further extended to suspect and non-target screening (SNTS) by means of LC coupled to high-resolution MS/MS. First, well-defined workflows for SNTS were validated by applying the previously developed method to an extended list of compounds (83), and then, to the same real urine samples. From a list of approximately 4000 suspects, 33 were annotated at levels from 1 to 3, with food additives/ingredients and personal care products being the most abundant ones. In the non-target approach, the search was limited to molecules containing S, Cl and/or Br atoms, annotating 4 pharmaceuticals. The results from this study showed that the combination of the lower limits of detection of MS/MS and the identification power of high-resolution MS/MS is still compulsory for a more accurate definition of human exposome in urine samples.