Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry
Five commercial ionic liquid (IL) columns have been evaluated for the first time for the gas chromatography-mass spectrometry (GC-MS) analysis of low molecular weight carbohydrate (LMWC) standards (mono-, di-, and trisaccharides, inositols, and iminosugars). A previous derivatization step was necess...
| Autores: | , , , , |
|---|---|
| Formato: | artículo |
| Fecha de publicación: | 2019 |
| País: | España |
| Recursos: | Consejo Superior de Investigaciones Científicas (CSIC) |
| Repositorio: | DIGITAL.CSIC. Repositorio Institucional del CSIC |
| OAI Identifier: | oai:digital.csic.es:10261/203017 |
| Acesso em linha: | http://hdl.handle.net/10261/203017 |
| Access Level: | acceso abierto |
| Palavra-chave: | Low molecular weight carbohydrates Gas chromatography-mass spectrometry Ionic liquids Stationary phases Hyacinth Mulberry |
| id |
ES_d0cb104f1316b0fd727d962c3e11805d |
|---|---|
| oai_identifier_str |
oai:digital.csic.es:10261/203017 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometryRodríguez-Sánchez, SoniaSoria, Ana C.Lebrón-Aguilar, RosaSanz, M. LuzRuiz-Matute, Ana I.Low molecular weight carbohydratesGas chromatography-mass spectrometryIonic liquidsStationary phasesHyacinthMulberryFive commercial ionic liquid (IL) columns have been evaluated for the first time for the gas chromatography-mass spectrometry (GC-MS) analysis of low molecular weight carbohydrate (LMWC) standards (mono-, di-, and trisaccharides, inositols, and iminosugars). A previous derivatization step was necessary to convert the LMWCs into their volatile and stable derivatives. Compared with conventional GC stationary phases, such as HP-1 and Supelcowax 10, IL columns have shown a different selectivity in the separation of target compounds. Among the IL columns, only SLB™-IL82 allowed the elution of all the LMWCs studied. Its performance in terms of peak width and asymmetry, evaluated under different oven temperature conditions, was shown to be dependent on the carbohydrate class considered. As an example of application, a SLB™-IL82 column was successfully used to separate the complex mixtures of LMWCs in hyacinth and mulberry extracts. This column is an interesting alternative to the conventional stationary phases used in the GC analysis of LMWCs in real-world samples. [Figure not available: see fulltext.].This work was funded by the Ministerio de Economía, Industria y Competitividad of Spain [project AGL2016- 80475-R, AEI/FEDER, UE], the Comunidad de Madrid and European funding from FSE and FEDER programs [project S2018/BAA-4393, AVANSECAL-II-CM], and the Fundación Ramón Areces [project CIVP17A2843]Springer NatureMinisterio de Economía y Competitividad (España)Comunidad de MadridEuropean CommissionFundación Ramón ArecesConsejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]2020202020192020info:eu-repo/semantics/articlehttp://purl.org/coar/resource_type/c_6501http://hdl.handle.net/10261/203017reponame:DIGITAL.CSIC. Repositorio Institucional del CSICinstname:Consejo Superior de Investigaciones Científicas (CSIC)Inglés#PLACEHOLDER_PARENT_METADATA_VALUE##PLACEHOLDER_PARENT_METADATA_VALUE#info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/AGL2016-80475-RS2018/BAA-4393/AVANSECAL-II-CMhttp://dx.doi.org/10.1007/s00216-019-02118-0Síinfo:eu-repo/semantics/openAccessoai:digital.csic.es:10261/2030172026-05-22T06:33:51Z |
| dc.title.none.fl_str_mv |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry |
| title |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry |
| spellingShingle |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry Rodríguez-Sánchez, Sonia Low molecular weight carbohydrates Gas chromatography-mass spectrometry Ionic liquids Stationary phases Hyacinth Mulberry |
| title_short |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry |
| title_full |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry |
| title_fullStr |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry |
| title_full_unstemmed |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry |
| title_sort |
Evaluation of different ionic liquid stationary phases for the analysis of carbohydrates by gas chromatography-mass spectrometry |
| dc.creator.none.fl_str_mv |
Rodríguez-Sánchez, Sonia Soria, Ana C. Lebrón-Aguilar, Rosa Sanz, M. Luz Ruiz-Matute, Ana I. |
| author |
Rodríguez-Sánchez, Sonia |
| author_facet |
Rodríguez-Sánchez, Sonia Soria, Ana C. Lebrón-Aguilar, Rosa Sanz, M. Luz Ruiz-Matute, Ana I. |
| author_role |
author |
| author2 |
Soria, Ana C. Lebrón-Aguilar, Rosa Sanz, M. Luz Ruiz-Matute, Ana I. |
| author2_role |
author author author author |
| dc.contributor.none.fl_str_mv |
Ministerio de Economía y Competitividad (España) Comunidad de Madrid European Commission Fundación Ramón Areces Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72] |
| dc.subject.none.fl_str_mv |
Low molecular weight carbohydrates Gas chromatography-mass spectrometry Ionic liquids Stationary phases Hyacinth Mulberry |
| topic |
Low molecular weight carbohydrates Gas chromatography-mass spectrometry Ionic liquids Stationary phases Hyacinth Mulberry |
| description |
Five commercial ionic liquid (IL) columns have been evaluated for the first time for the gas chromatography-mass spectrometry (GC-MS) analysis of low molecular weight carbohydrate (LMWC) standards (mono-, di-, and trisaccharides, inositols, and iminosugars). A previous derivatization step was necessary to convert the LMWCs into their volatile and stable derivatives. Compared with conventional GC stationary phases, such as HP-1 and Supelcowax 10, IL columns have shown a different selectivity in the separation of target compounds. Among the IL columns, only SLB™-IL82 allowed the elution of all the LMWCs studied. Its performance in terms of peak width and asymmetry, evaluated under different oven temperature conditions, was shown to be dependent on the carbohydrate class considered. As an example of application, a SLB™-IL82 column was successfully used to separate the complex mixtures of LMWCs in hyacinth and mulberry extracts. This column is an interesting alternative to the conventional stationary phases used in the GC analysis of LMWCs in real-world samples. [Figure not available: see fulltext.]. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019 2020 2020 2020 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article http://purl.org/coar/resource_type/c_6501 |
| format |
article |
| dc.identifier.none.fl_str_mv |
http://hdl.handle.net/10261/203017 |
| url |
http://hdl.handle.net/10261/203017 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
#PLACEHOLDER_PARENT_METADATA_VALUE# #PLACEHOLDER_PARENT_METADATA_VALUE# info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/AGL2016-80475-R S2018/BAA-4393/AVANSECAL-II-CM http://dx.doi.org/10.1007/s00216-019-02118-0 Sí |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.publisher.none.fl_str_mv |
Springer Nature |
| publisher.none.fl_str_mv |
Springer Nature |
| dc.source.none.fl_str_mv |
reponame:DIGITAL.CSIC. Repositorio Institucional del CSIC instname:Consejo Superior de Investigaciones Científicas (CSIC) |
| instname_str |
Consejo Superior de Investigaciones Científicas (CSIC) |
| reponame_str |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| collection |
DIGITAL.CSIC. Repositorio Institucional del CSIC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869420205882474496 |
| score |
15,811543 |