Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing
The aim of this study was to evaluate the inter- and intraobserver correlation of the different intrapartum-transperineal-ultrasound-parameters(ITU) (angle of progression (AoP), progression-distance (PD), head-direction (HD), midline-angle (MLA) and head-perineum distance (HPD)) with contraction and...
| Authors: | , , , , , |
|---|---|
| Format: | article |
| Status: | Versión aceptada para publicación |
| Publication Date: | 2018 |
| Country: | España |
| Institution: | Universidad de Sevilla (US) |
| Repository: | idUS. Depósito de Investigación de la Universidad de Sevilla |
| OAI Identifier: | oai:idus.us.es:11441/161624 |
| Online Access: | https://hdl.handle.net/11441/161624 https://doi.org/10.1080/01443615.2017.1354179 |
| Access Level: | Open access |
| Keyword: | Intrapartum ultrasound, labor Pushing Translabial ultrasound Transperineal ultrasound |
| id |
ES_d0112ec0130f2602eb2eda89edc14b60 |
|---|---|
| oai_identifier_str |
oai:idus.us.es:11441/161624 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushingSáinz Bueno, José AntonioFernández Palacín, AnaBorrero González, CarlotaAquise, AdrianaRamos, ZenaidaGarcía Mejido, José AntonioIntrapartum ultrasound, laborPushingTranslabial ultrasoundTransperineal ultrasoundThe aim of this study was to evaluate the inter- and intraobserver correlation of the different intrapartum-transperineal-ultrasound-parameters(ITU) (angle of progression (AoP), progression-distance (PD), head-direction (HD), midline-angle (MLA) and head-perineum distance (HPD)) with contraction and pushing. We evaluated 28 nulliparous women at full dilatation under epidural analgesia. We performed a transperineal ultrasound evaluating AoP and PD in the longitudinal plane, and MLA and HPD in the transverse plane. Interclass correlation coefficients (ICC) with 95% CIs and Bland–Altman analysis were used to assess intra- and interobserver measurement’s repeatability. The ICC of the ITU for the same observer was adequate for all the parameters (p < .005) AoP 0.98 (95%CI, 0.96–0.99), PD 0.98 (95%CI, 0.97–0.99), MLA 0.99 (95%CI, 0.97–0.99), HPD 0.96 (95%CI, 0.88–0.99). The ICC of the ITU for interobserver was: AoP 0.93 (95%CI, 0.79–0.98), PD 0.92 (95%CI, 0.76–0.97), MLA 0.77 (95%CI, 0.42–0.92), HPD 0.47 (95%CI, −0.12–0.8). The HD had an interobserver correlation of 0.53 (95%CI, 0.1–0.9) (Kappa C). The mean difference of the AoP was 2.42°, of the PD 1 mm and 0.28° MLA (Bland–Altman test). ITU has an adequate intra- and interobserver correlation for its use with contraction and pushing under epidural analgesia.Informa HealthcareCirugíaMedicina Preventiva y Salud Pública2018info:eu-repo/semantics/articleinfo:eu-repo/semantics/acceptedVersionapplication/pdfapplication/pdfhttps://hdl.handle.net/11441/161624https://doi.org/10.1080/01443615.2017.1354179reponame:idUS. Depósito de Investigación de la Universidad de Sevillainstname:Universidad de Sevilla (US)InglésJournal of obstetrics and gynaecology, 38 (3), 333-338.https://www.tandfonline.com/doi/full/10.1080/01443615.2017.1354179info:eu-repo/semantics/openAccessoai:idus.us.es:11441/1616242026-06-17T12:51:07Z |
| dc.title.none.fl_str_mv |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing |
| title |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing |
| spellingShingle |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing Sáinz Bueno, José Antonio Intrapartum ultrasound, labor Pushing Translabial ultrasound Transperineal ultrasound |
| title_short |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing |
| title_full |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing |
| title_fullStr |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing |
| title_full_unstemmed |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing |
| title_sort |
Intra and interobserver variability of intrapartum transperineal ultrasound measurements with contraction and pushing |
| dc.creator.none.fl_str_mv |
Sáinz Bueno, José Antonio Fernández Palacín, Ana Borrero González, Carlota Aquise, Adriana Ramos, Zenaida García Mejido, José Antonio |
| author |
Sáinz Bueno, José Antonio |
| author_facet |
Sáinz Bueno, José Antonio Fernández Palacín, Ana Borrero González, Carlota Aquise, Adriana Ramos, Zenaida García Mejido, José Antonio |
| author_role |
author |
| author2 |
Fernández Palacín, Ana Borrero González, Carlota Aquise, Adriana Ramos, Zenaida García Mejido, José Antonio |
| author2_role |
author author author author author |
| dc.contributor.none.fl_str_mv |
Cirugía Medicina Preventiva y Salud Pública |
| dc.subject.none.fl_str_mv |
Intrapartum ultrasound, labor Pushing Translabial ultrasound Transperineal ultrasound |
| topic |
Intrapartum ultrasound, labor Pushing Translabial ultrasound Transperineal ultrasound |
| description |
The aim of this study was to evaluate the inter- and intraobserver correlation of the different intrapartum-transperineal-ultrasound-parameters(ITU) (angle of progression (AoP), progression-distance (PD), head-direction (HD), midline-angle (MLA) and head-perineum distance (HPD)) with contraction and pushing. We evaluated 28 nulliparous women at full dilatation under epidural analgesia. We performed a transperineal ultrasound evaluating AoP and PD in the longitudinal plane, and MLA and HPD in the transverse plane. Interclass correlation coefficients (ICC) with 95% CIs and Bland–Altman analysis were used to assess intra- and interobserver measurement’s repeatability. The ICC of the ITU for the same observer was adequate for all the parameters (p < .005) AoP 0.98 (95%CI, 0.96–0.99), PD 0.98 (95%CI, 0.97–0.99), MLA 0.99 (95%CI, 0.97–0.99), HPD 0.96 (95%CI, 0.88–0.99). The ICC of the ITU for interobserver was: AoP 0.93 (95%CI, 0.79–0.98), PD 0.92 (95%CI, 0.76–0.97), MLA 0.77 (95%CI, 0.42–0.92), HPD 0.47 (95%CI, −0.12–0.8). The HD had an interobserver correlation of 0.53 (95%CI, 0.1–0.9) (Kappa C). The mean difference of the AoP was 2.42°, of the PD 1 mm and 0.28° MLA (Bland–Altman test). ITU has an adequate intra- and interobserver correlation for its use with contraction and pushing under epidural analgesia. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/acceptedVersion |
| format |
article |
| status_str |
acceptedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/11441/161624 https://doi.org/10.1080/01443615.2017.1354179 |
| url |
https://hdl.handle.net/11441/161624 https://doi.org/10.1080/01443615.2017.1354179 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Journal of obstetrics and gynaecology, 38 (3), 333-338. https://www.tandfonline.com/doi/full/10.1080/01443615.2017.1354179 |
| dc.rights.none.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Informa Healthcare |
| publisher.none.fl_str_mv |
Informa Healthcare |
| dc.source.none.fl_str_mv |
reponame:idUS. Depósito de Investigación de la Universidad de Sevilla instname:Universidad de Sevilla (US) |
| instname_str |
Universidad de Sevilla (US) |
| reponame_str |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| collection |
idUS. Depósito de Investigación de la Universidad de Sevilla |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869420140360105985 |
| score |
15,812455 |