Chemically synthesized chevron-like graphene nanoribbons for electrochemical sensors development: determination of epinephrine

We employ chevron-like graphene nanoribbons (GNRs) synthesized by a solution-based chemical route to develop a novel electrochemical sensor for determination of the neurotransmitter epinephrine (EPI). The sensor surface, a glassy carbon electrode modified with GNRs, is characterized by atomic force...

ver descrição completa

Detalhes bibliográficos
Autores: Sainz Vaque, Raquel, del Pozo, María, Vilas Varela, Manuel, Castro Esteban, Jesús, Pérez Corral, María, Vázquez, Luis, Blanco Gil, Elías, Peña, Diego, Martín-Gago, José A., Ellis, Gary J., Petit Domínguez, María Dolores, Quintana Mani, María del Carmen, Casero Junquera, María Elena
Tipo de documento: artigo
Data de publicação:2020
País:España
Recursos:Universidad Autónoma de Madrid
Repositório:Biblos-e Archivo. Repositorio Institucional de la UAM
Idioma:inglês
OAI Identifier:oai:repositorio.uam.es:10486/720138
Acesso em linha:http://hdl.handle.net/10486/720138
https://dx.doi.org/10.1038/s41598-020-71554-1
Access Level:Acceso aberto
Palavra-chave:electrochemical techniques
epinephrine
graphite
nanotubes, carbon
spectrum analysis
Química
Descrição
Resumo:We employ chevron-like graphene nanoribbons (GNRs) synthesized by a solution-based chemical route to develop a novel electrochemical sensor for determination of the neurotransmitter epinephrine (EPI). The sensor surface, a glassy carbon electrode modified with GNRs, is characterized by atomic force microscopy, scanning electron microscopy and Raman spectroscopy, which show that the electrode surface modification comprises of bi-dimensional multilayer-stacked GNRs that retain their molecular structure. The charge transfer process occurring at the electrode interface is evaluated by electrochemical impedance spectroscopy. The sensor is applied to the determination of EPI, employing as an analytical signal the reduction peak corresponding to the epinephrinechrome–leucoepinephrinechrome transition (E = − 0.25 V) instead of the oxidation peak usually employed in the literature (E = + 0.6 V) in order to minimize interferences. The results obtained demonstrate that chevron-like nanoribbons synthesized by solution methods exhibit reliable electrocatalytic activity for EPI determination. Using differential pulse voltammetry, we obtain a linear concentration range from 6.4 × 10–6 to 1.0 × 10–4 M and a detection limit of 2.1 × 10–6 M. The applicability of the sensor was evaluated by determining EPI in pharmaceutical samples with satisfactory results