The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study

Background: Given the potential benefits of introducing ultrasound in the clinical assessment of muscle disorders, this study aimed to assess the feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric clinical setting. Methods: Cross-sectional pilot study in 2...

Descripción completa

Detalles Bibliográficos
Autores: Meza Valderrama, Delky, Sánchez-Rodríguez, Dolores, Perkisas, Stany, Duran Jordà, Xavier, 1974-, Bastijns, Sophie, Dávalos Yerovi, Vanesa, Da Costa, Elizabeth, Marco Navarro, Ester
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2022
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:10230/53898
Acceso en línea:http://hdl.handle.net/10230/53898
http://dx.doi.org/10.1186/s12877-022-02811-3
Access Level:acceso abierto
Palabra clave:Forearm muscle thickness
Inter-rater reliability
Intra-rater reliability
Muscle ultrasound
Ultrasound feasibility
id ES_ce21f188d8bc0200eebeb86fa6e332a3
oai_identifier_str oai:recercat.cat:10230/53898
network_acronym_str ES
network_name_str España
repository_id_str
spelling The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot studyMeza Valderrama, DelkySánchez-Rodríguez, DoloresPerkisas, StanyDuran Jordà, Xavier, 1974-Bastijns, SophieDávalos Yerovi, VanesaDa Costa, ElizabethMarco Navarro, EsterForearm muscle thicknessInter-rater reliabilityIntra-rater reliabilityMuscle ultrasoundUltrasound feasibilityBackground: Given the potential benefits of introducing ultrasound in the clinical assessment of muscle disorders, this study aimed to assess the feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric clinical setting. Methods: Cross-sectional pilot study in 25 participants (12 patients aged ≥ 70 years in an acute geriatric ward and 13 healthy volunteers aged 25-50 years), assessed by three raters. Muscle thickness measurement was estimated as the distance between the subcutaneous adipose tissue-muscle interface and muscle-bone interface of the radius at 30% proximal of the distance between the styloid process and distal insertion of the biceps brachii muscle of the dominant forearm. Examinations were repeated three times by each rater and intra- and inter-rater reliability was calculated. Feasibility analysis included consideration of technological, economic, legal, operational, and scheduling (TELOS) components. Results: Mean muscle-thickness measurement difference between groups was 4.4 mm (95% confidence interval [CI] 2.4 mm to 6.3 mm], p < 0.001). Intra-rater reliability of muscle-thickness assessment was excellent, with intraclass correlation coefficient (ICC) of 0.947 (95%CI 0.902 to 0.974), 0.969 (95%CI 0.942 to 0.985), and 0.950 (95%CI 0.907 to 0.975) for observer A, B, and C, respectively. Inter-rater comparison showed good agreement (ICC of 0.873 [95%CI 0.73 to 0.94]). Four of the 17 TELOS components considered led to specific recommendations to improve the procedure's feasibility in clinical practice. Conclusion: Our findings suggest that US is a feasible tool to assess the thickness of the forearm muscles with good inter-rater and excellent intra-rater reliability in a sample of hospitalized geriatric patients, making it a promising option for use in clinical practice.BioMed Central202220222022info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfapplication/pdfhttp://hdl.handle.net/10230/53898http://dx.doi.org/10.1186/s12877-022-02811-3reponame:Recercat. Dipósit de la Recerca de Catalunyainstname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)InglésBMC Geriatr. 2022 Feb 18;22(1):137© The Author(s) 2022. Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.http://creativecommons.org/licenses/by/4.0/info:eu-repo/semantics/openAccessoai:recercat.cat:10230/538982026-05-29T05:05:01Z
dc.title.none.fl_str_mv The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
spellingShingle The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
Meza Valderrama, Delky
Forearm muscle thickness
Inter-rater reliability
Intra-rater reliability
Muscle ultrasound
Ultrasound feasibility
title_short The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_full The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_fullStr The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_full_unstemmed The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
title_sort The feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric inpatient setting: a cross-sectional pilot study
dc.creator.none.fl_str_mv Meza Valderrama, Delky
Sánchez-Rodríguez, Dolores
Perkisas, Stany
Duran Jordà, Xavier, 1974-
Bastijns, Sophie
Dávalos Yerovi, Vanesa
Da Costa, Elizabeth
Marco Navarro, Ester
author Meza Valderrama, Delky
author_facet Meza Valderrama, Delky
Sánchez-Rodríguez, Dolores
Perkisas, Stany
Duran Jordà, Xavier, 1974-
Bastijns, Sophie
Dávalos Yerovi, Vanesa
Da Costa, Elizabeth
Marco Navarro, Ester
author_role author
author2 Sánchez-Rodríguez, Dolores
Perkisas, Stany
Duran Jordà, Xavier, 1974-
Bastijns, Sophie
Dávalos Yerovi, Vanesa
Da Costa, Elizabeth
Marco Navarro, Ester
author2_role author
author
author
author
author
author
author
dc.subject.none.fl_str_mv Forearm muscle thickness
Inter-rater reliability
Intra-rater reliability
Muscle ultrasound
Ultrasound feasibility
topic Forearm muscle thickness
Inter-rater reliability
Intra-rater reliability
Muscle ultrasound
Ultrasound feasibility
description Background: Given the potential benefits of introducing ultrasound in the clinical assessment of muscle disorders, this study aimed to assess the feasibility and reliability of measuring forearm muscle thickness by ultrasound in a geriatric clinical setting. Methods: Cross-sectional pilot study in 25 participants (12 patients aged ≥ 70 years in an acute geriatric ward and 13 healthy volunteers aged 25-50 years), assessed by three raters. Muscle thickness measurement was estimated as the distance between the subcutaneous adipose tissue-muscle interface and muscle-bone interface of the radius at 30% proximal of the distance between the styloid process and distal insertion of the biceps brachii muscle of the dominant forearm. Examinations were repeated three times by each rater and intra- and inter-rater reliability was calculated. Feasibility analysis included consideration of technological, economic, legal, operational, and scheduling (TELOS) components. Results: Mean muscle-thickness measurement difference between groups was 4.4 mm (95% confidence interval [CI] 2.4 mm to 6.3 mm], p < 0.001). Intra-rater reliability of muscle-thickness assessment was excellent, with intraclass correlation coefficient (ICC) of 0.947 (95%CI 0.902 to 0.974), 0.969 (95%CI 0.942 to 0.985), and 0.950 (95%CI 0.907 to 0.975) for observer A, B, and C, respectively. Inter-rater comparison showed good agreement (ICC of 0.873 [95%CI 0.73 to 0.94]). Four of the 17 TELOS components considered led to specific recommendations to improve the procedure's feasibility in clinical practice. Conclusion: Our findings suggest that US is a feasible tool to assess the thickness of the forearm muscles with good inter-rater and excellent intra-rater reliability in a sample of hospitalized geriatric patients, making it a promising option for use in clinical practice.
publishDate 2022
dc.date.none.fl_str_mv 2022
2022
2022
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.none.fl_str_mv http://hdl.handle.net/10230/53898
http://dx.doi.org/10.1186/s12877-022-02811-3
url http://hdl.handle.net/10230/53898
http://dx.doi.org/10.1186/s12877-022-02811-3
dc.language.none.fl_str_mv Inglés
language_invalid_str_mv Inglés
dc.relation.none.fl_str_mv BMC Geriatr. 2022 Feb 18;22(1):137
dc.rights.none.fl_str_mv http://creativecommons.org/licenses/by/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv http://creativecommons.org/licenses/by/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv BioMed Central
publisher.none.fl_str_mv BioMed Central
dc.source.none.fl_str_mv reponame:Recercat. Dipósit de la Recerca de Catalunya
instname:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
instname_str Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
reponame_str Recercat. Dipósit de la Recerca de Catalunya
collection Recercat. Dipósit de la Recerca de Catalunya
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869419962795294720
score 15,811543