Positioning of the cross-stitch on the modified Kessler core tendon suture
[EN] Cryopreserved human tendons were sutured with different variations of a modified Kessler-type grasping suture in a series of different designs in order to assess the influence of the distance between the cross-stitch on the core suture (5 and 10 mm from the cut tendon edge) on the peripheral su...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2018 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/125679 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/125679 |
| Access Level: | acceso abierto |
| Palabra clave: | Biomechanics Core and peripheral suture Flexor tendon Repair Resistance MAQUINAS Y MOTORES TERMICOS FISICA APLICADA |
| id |
ES_cdd98fd2f49fa8ff7bcb1cdbdc20e8b4 |
|---|---|
| oai_identifier_str |
oai:riunet.upv.es:10251/125679 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Positioning of the cross-stitch on the modified Kessler core tendon sutureGIL SANTOS, LUISGomar-Sancho, F.Monleón Pradas, Manuel|||0000-0001-6457-0414Más Estellés, Jorge|||0000-0001-8446-6737BiomechanicsCore and peripheral sutureFlexor tendonRepairResistanceMAQUINAS Y MOTORES TERMICOSFISICA APLICADA[EN] Cryopreserved human tendons were sutured with different variations of a modified Kessler-type grasping suture in a series of different designs in order to assess the influence of the distance between the cross-stitch on the core suture (5 and 10 mm from the cut tendon edge) on the peripheral suture. An original mathematical model was employed to explain the mechanical behavior (strength, deformation, and distribution of load) of the different suture designs. The effect of the peripheral epitendinous suture, combined with the distance of the core suture, was evaluated. The variation of core suture distance had no relevant consequences on the overall resilience of the design. However, increasing the distance between the cross-stitches of the core suture reduces the deformation that is absorbed not only by the core suture itself but also by the peripheral suture. Adding a peripheral epitendinous suture to a 10-mm design almost doubles the breaking load in absolute values. The mathematical model predicts that the peripheral suture will support a greater load when the distance of the core suture cross-stitches is increased. The evidence level is II.ElsevierDepartamento de Física AplicadaDepartamento de Termodinámica AplicadaCentro de Biomateriales e Ingeniería TisularEscuela Técnica Superior de Ingeniería IndustrialEscuela Técnica Superior de Ingeniería InformáticaRepositorio Institucional de la Universitat Politècnica de València Riunet20182018-01-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfapplication/pdfhttps://riunet.upv.es/handle/10251/125679reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Reserva de todos los derechoshttp://rightsstatements.org/vocab/InC/1.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/1256792026-06-13T07:49:27Z |
| dc.title.none.fl_str_mv |
Positioning of the cross-stitch on the modified Kessler core tendon suture |
| title |
Positioning of the cross-stitch on the modified Kessler core tendon suture |
| spellingShingle |
Positioning of the cross-stitch on the modified Kessler core tendon suture GIL SANTOS, LUIS Biomechanics Core and peripheral suture Flexor tendon Repair Resistance MAQUINAS Y MOTORES TERMICOS FISICA APLICADA |
| title_short |
Positioning of the cross-stitch on the modified Kessler core tendon suture |
| title_full |
Positioning of the cross-stitch on the modified Kessler core tendon suture |
| title_fullStr |
Positioning of the cross-stitch on the modified Kessler core tendon suture |
| title_full_unstemmed |
Positioning of the cross-stitch on the modified Kessler core tendon suture |
| title_sort |
Positioning of the cross-stitch on the modified Kessler core tendon suture |
| dc.creator.none.fl_str_mv |
GIL SANTOS, LUIS Gomar-Sancho, F. Monleón Pradas, Manuel|||0000-0001-6457-0414 Más Estellés, Jorge|||0000-0001-8446-6737 |
| author |
GIL SANTOS, LUIS |
| author_facet |
GIL SANTOS, LUIS Gomar-Sancho, F. Monleón Pradas, Manuel|||0000-0001-6457-0414 Más Estellés, Jorge|||0000-0001-8446-6737 |
| author_role |
author |
| author2 |
Gomar-Sancho, F. Monleón Pradas, Manuel|||0000-0001-6457-0414 Más Estellés, Jorge|||0000-0001-8446-6737 |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Departamento de Física Aplicada Departamento de Termodinámica Aplicada Centro de Biomateriales e Ingeniería Tisular Escuela Técnica Superior de Ingeniería Industrial Escuela Técnica Superior de Ingeniería Informática Repositorio Institucional de la Universitat Politècnica de València Riunet |
| dc.subject.none.fl_str_mv |
Biomechanics Core and peripheral suture Flexor tendon Repair Resistance MAQUINAS Y MOTORES TERMICOS FISICA APLICADA |
| topic |
Biomechanics Core and peripheral suture Flexor tendon Repair Resistance MAQUINAS Y MOTORES TERMICOS FISICA APLICADA |
| description |
[EN] Cryopreserved human tendons were sutured with different variations of a modified Kessler-type grasping suture in a series of different designs in order to assess the influence of the distance between the cross-stitch on the core suture (5 and 10 mm from the cut tendon edge) on the peripheral suture. An original mathematical model was employed to explain the mechanical behavior (strength, deformation, and distribution of load) of the different suture designs. The effect of the peripheral epitendinous suture, combined with the distance of the core suture, was evaluated. The variation of core suture distance had no relevant consequences on the overall resilience of the design. However, increasing the distance between the cross-stitches of the core suture reduces the deformation that is absorbed not only by the core suture itself but also by the peripheral suture. Adding a peripheral epitendinous suture to a 10-mm design almost doubles the breaking load in absolute values. The mathematical model predicts that the peripheral suture will support a greater load when the distance of the core suture cross-stitches is increased. The evidence level is II. |
| publishDate |
2018 |
| dc.date.none.fl_str_mv |
2018 2018-01-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://riunet.upv.es/handle/10251/125679 |
| url |
https://riunet.upv.es/handle/10251/125679 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reserva de todos los derechos http://rightsstatements.org/vocab/InC/1.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reserva de todos los derechos http://rightsstatements.org/vocab/InC/1.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf application/pdf |
| dc.publisher.none.fl_str_mv |
Elsevier |
| publisher.none.fl_str_mv |
Elsevier |
| dc.source.none.fl_str_mv |
reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia instname:Universitat Politècnica de València (UPV) |
| instname_str |
Universitat Politècnica de València (UPV) |
| reponame_str |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| collection |
RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869419892556431360 |
| score |