Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods
The centrifugal liquid membrane (CLM) cell has been utilized for chiroptical studies of liquid-liquid interfaces with a conventional circular dichroism (CD) spectropolarimeter. These studies required the characterization of optical properties of the rotating cylindrical CLM glass cell, which was use...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2011 |
| País: | España |
| Institución: | Universidad de Barcelona |
| Repositorio: | Dipòsit Digital de la UB |
| OAI Identifier: | oai:diposit.ub.edu:2445/20724 |
| Acceso en línea: | https://hdl.handle.net/2445/20724 |
| Access Level: | acceso abierto |
| Palabra clave: | Quiralitat Dicroisme circular Refracció doble Porfirines Agregació (Química) Chirality Circular dichroism Double refraction Porphyrins Aggregation (Chemistry) |
| id |
ES_cd938e70398fc9d930d0d128b0f6b2eb |
|---|---|
| oai_identifier_str |
oai:diposit.ub.edu:2445/20724 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methodsTakechi, HideakiArteaga Barriel, OriolRibó i Trujillo, Josep M.Watarai, HitoshiQuiralitatDicroisme circularRefracció doblePorfirinesAgregació (Química)ChiralityCircular dichroismDouble refractionPorphyrinsAggregation (Chemistry)The centrifugal liquid membrane (CLM) cell has been utilized for chiroptical studies of liquid-liquid interfaces with a conventional circular dichroism (CD) spectropolarimeter. These studies required the characterization of optical properties of the rotating cylindrical CLM glass cell, which was used under the high speed rotation. In the present study, we have measured the circular and linear dichroism (CD and LD) spectra and the circular and linear birefringence (CB and LB) spectra of the CLM cell itself as well as those of porphyrine aggregates formed at the liquid-liquid interface in the CLM cell, applying Mueller matrix measurement method. From the results, it was confirmed that the CLM-CD spectra of the interfacial porphyrin aggregates observed by a conventional CD spectropolarimeter should be correct irrespective of LD and LB signals in the CLM cell.MDPI Publishing2011info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/2445/20724Articles publicats en revistes (Química Inorgànica i Orgànica)reponame:Dipòsit Digital de la UBinstname:Universidad de BarcelonaInglésReproducció del document publicat a: http://dx.doi.org/10.3390/molecules16053636Molecules, 2011, 16(5), 3636-3647http://dx.doi.org/10.3390/molecules16053636cc-by, (c) Takechi et al., 2011http://creativecommons.org/licenses/by/3.0/esinfo:eu-repo/semantics/openAccessoai:diposit.ub.edu:2445/207242026-05-27T06:46:51Z |
| dc.title.none.fl_str_mv |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods |
| title |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods |
| spellingShingle |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods Takechi, Hideaki Quiralitat Dicroisme circular Refracció doble Porfirines Agregació (Química) Chirality Circular dichroism Double refraction Porphyrins Aggregation (Chemistry) |
| title_short |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods |
| title_full |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods |
| title_fullStr |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods |
| title_full_unstemmed |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods |
| title_sort |
Chiroptical measurement of chiral aggregates at liquid-liquid interface in centrifugal liquid membrane cell by Mueller matrix and conventional circular dichroism methods |
| dc.creator.none.fl_str_mv |
Takechi, Hideaki Arteaga Barriel, Oriol Ribó i Trujillo, Josep M. Watarai, Hitoshi |
| author |
Takechi, Hideaki |
| author_facet |
Takechi, Hideaki Arteaga Barriel, Oriol Ribó i Trujillo, Josep M. Watarai, Hitoshi |
| author_role |
author |
| author2 |
Arteaga Barriel, Oriol Ribó i Trujillo, Josep M. Watarai, Hitoshi |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Quiralitat Dicroisme circular Refracció doble Porfirines Agregació (Química) Chirality Circular dichroism Double refraction Porphyrins Aggregation (Chemistry) |
| topic |
Quiralitat Dicroisme circular Refracció doble Porfirines Agregació (Química) Chirality Circular dichroism Double refraction Porphyrins Aggregation (Chemistry) |
| description |
The centrifugal liquid membrane (CLM) cell has been utilized for chiroptical studies of liquid-liquid interfaces with a conventional circular dichroism (CD) spectropolarimeter. These studies required the characterization of optical properties of the rotating cylindrical CLM glass cell, which was used under the high speed rotation. In the present study, we have measured the circular and linear dichroism (CD and LD) spectra and the circular and linear birefringence (CB and LB) spectra of the CLM cell itself as well as those of porphyrine aggregates formed at the liquid-liquid interface in the CLM cell, applying Mueller matrix measurement method. From the results, it was confirmed that the CLM-CD spectra of the interfacial porphyrin aggregates observed by a conventional CD spectropolarimeter should be correct irrespective of LD and LB signals in the CLM cell. |
| publishDate |
2011 |
| dc.date.none.fl_str_mv |
2011 |
| dc.type.none.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2445/20724 |
| url |
https://hdl.handle.net/2445/20724 |
| dc.language.none.fl_str_mv |
Inglés |
| language_invalid_str_mv |
Inglés |
| dc.relation.none.fl_str_mv |
Reproducció del document publicat a: http://dx.doi.org/10.3390/molecules16053636 Molecules, 2011, 16(5), 3636-3647 http://dx.doi.org/10.3390/molecules16053636 |
| dc.rights.none.fl_str_mv |
cc-by, (c) Takechi et al., 2011 http://creativecommons.org/licenses/by/3.0/es info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
cc-by, (c) Takechi et al., 2011 http://creativecommons.org/licenses/by/3.0/es |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
MDPI Publishing |
| publisher.none.fl_str_mv |
MDPI Publishing |
| dc.source.none.fl_str_mv |
Articles publicats en revistes (Química Inorgànica i Orgànica) reponame:Dipòsit Digital de la UB instname:Universidad de Barcelona |
| instname_str |
Universidad de Barcelona |
| reponame_str |
Dipòsit Digital de la UB |
| collection |
Dipòsit Digital de la UB |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869419867382218752 |
| score |
15,300724 |