Study of Full-Color Multiplexed Transmission Holograms of Diffusing Objects Recorded in Photopolymer Bayfol HX
A wavelength multiplexing procedure for color transmission volume holograms of diffusing objects recorded in Bayfol® HX200 photopolymer is proposed. For the recording, three lasers of 442 nm, 532 nm and 633 nm, and a Spectralon® diffusing object were used for monochromatic and polychromatic calibrat...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Estado: | Versión publicada |
| Fecha de publicación: | 2021 |
| País: | España |
| Institución: | Universitat de Lleida (UdL) |
| Repositorio: | Repositori Obert UdL |
| OAI Identifier: | oai:repositori.udl.cat:10459.1/84098 |
| Acceso en línea: | https://doi.org/10.3390/photonics8110465 http://hdl.handle.net/10459.1/84098 |
| Access Level: | acceso abierto |
| Palabra clave: | full-color holography volume hologram transmission hologram photopolymer Holografia |
| Sumario: | A wavelength multiplexing procedure for color transmission volume holograms of diffusing objects recorded in Bayfol® HX200 photopolymer is proposed. For the recording, three lasers of 442 nm, 532 nm and 633 nm, and a Spectralon® diffusing object were used for monochromatic and polychromatic calibration. Monochromatic calibration shows that the maximum index modulation obtained for each wavelength was not enough to give 100% efficiency, although the efficiency values achieved in the case of monochromatic recordings with diffusing objects were high, at around 90% for 633 nm and 532 nm recordings, and 60% for 442 nm. The efficiency values obtained for multiplexed holograms were 19.1% for the 442 nm hologram, 25.9% for the 532 nm hologram and 15.2% for the 633 nm. |
|---|