Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter
[EN] The effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in a concentrated lithium bromide solution were investigated in a hydraulic circuit applying different flow steps and using a zero-resistance ammeter (ZRA). The flow steps consist in applying a...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2012 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/31148 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/31148 |
| Access Level: | acceso abierto |
| Palabra clave: | Copper Hydrodynamic Corrosion Lithium Bromide Stainless Steel Zero-Resistance Ammeter INGENIERIA QUIMICA |
| id |
ES_cb597c08c4d05aa1d5b3bf04cba2c32b |
|---|---|
| oai_identifier_str |
oai:riunet.upv.es:10251/31148 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeterMontañés, Maria-Teresa|||0000-0002-2620-6926Garcia-Anton, Jose|||0000-0002-0289-1324Pérez-Herranz, Valentín|||0000-0002-4010-0888Sánchez Tovar, RitaCopperHydrodynamic CorrosionLithium BromideStainless SteelZero-Resistance AmmeterINGENIERIA QUIMICA[EN] The effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in a concentrated lithium bromide solution were investigated in a hydraulic circuit applying different flow steps and using a zero-resistance ammeter (ZRA). The flow steps consist in applying a flow rate for sixty minutes after leaving the system under stagnant conditions for another sixty minutes; this procedure is repeated during eight hours. The magnitude of the steps is different depending on the flow regime studied, ranging from a Reynolds number of 633 to 5066. Results show that, when a flow step is applied, the galvanic current density increases and the galvanic potential shifts towards more negative values. However, with time, this increase in the galvanic current density is lower, reaching its lowest value in the last hour of the experiment at a Reynolds number of 5066. Thus, although the corrosion rate increases as Reynolds number increases, the protective corrosion products are generated earlier on the copper surface. © 2012 by ESG.The authors would like to express their gratitude to the MICINN for the financial support (project CTQ2009-07518), to the FPU grant given to Rita Sánchez Tovar, to FEDER (Fondo Europeo de Desarrollo Regional) and to Dr. Asunción Jaime for her translation assistance.Electrochemical Science GroupDepartamento de Ingeniería Química y NuclearEscuela Técnica Superior de Ingeniería IndustrialInstituto Universitario de Seguridad Industrial, Radiofísica y MedioambientalMinisterio de Ciencia e InnovaciónRepositorio Institucional de la Universitat Politècnica de València Riunet20122012-01-01journal articlehttp://purl.org/coar/resource_type/c_6501VoRhttp://purl.org/coar/version/c_970fb48d4fbd8a85info:eu-repo/semantics/articleapplication/pdfhttps://riunet.upv.es/handle/10251/31148reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valénciainstname:Universitat Politècnica de València (UPV)InglésengMinisterio de Ciencia e Innovación http://dx.doi.org/10.13039/501100004837 CTQ2009-07518 ESTUDIO DE LA CORROSION TERMOGALVANICA EN LAS MAQUINAS DE ABSORCION DE LIBR DE DOBLE EFECTO MEDIANTE TECNICAS ELECTROQUIMICAS Y DE IMAGENopen accesshttp://purl.org/coar/access_right/c_abf2Reserva de todos los derechoshttp://rightsstatements.org/vocab/InC/1.0/info:eu-repo/semantics/openAccessoai:riunet.upv.es:10251/311482026-06-13T07:49:27Z |
| dc.title.none.fl_str_mv |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter |
| title |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter |
| spellingShingle |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter Montañés, Maria-Teresa|||0000-0002-2620-6926 Copper Hydrodynamic Corrosion Lithium Bromide Stainless Steel Zero-Resistance Ammeter INGENIERIA QUIMICA |
| title_short |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter |
| title_full |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter |
| title_fullStr |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter |
| title_full_unstemmed |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter |
| title_sort |
Effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in lithium bromide using a zero-resistance ammeter |
| dc.creator.none.fl_str_mv |
Montañés, Maria-Teresa|||0000-0002-2620-6926 Garcia-Anton, Jose|||0000-0002-0289-1324 Pérez-Herranz, Valentín|||0000-0002-4010-0888 Sánchez Tovar, Rita |
| author |
Montañés, Maria-Teresa|||0000-0002-2620-6926 |
| author_facet |
Montañés, Maria-Teresa|||0000-0002-2620-6926 Garcia-Anton, Jose|||0000-0002-0289-1324 Pérez-Herranz, Valentín|||0000-0002-4010-0888 Sánchez Tovar, Rita |
| author_role |
author |
| author2 |
Garcia-Anton, Jose|||0000-0002-0289-1324 Pérez-Herranz, Valentín|||0000-0002-4010-0888 Sánchez Tovar, Rita |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Departamento de Ingeniería Química y Nuclear Escuela Técnica Superior de Ingeniería Industrial Instituto Universitario de Seguridad Industrial, Radiofísica y Medioambiental Ministerio de Ciencia e Innovación Repositorio Institucional de la Universitat Politècnica de València Riunet |
| dc.subject.none.fl_str_mv |
Copper Hydrodynamic Corrosion Lithium Bromide Stainless Steel Zero-Resistance Ammeter INGENIERIA QUIMICA |
| topic |
Copper Hydrodynamic Corrosion Lithium Bromide Stainless Steel Zero-Resistance Ammeter INGENIERIA QUIMICA |
| description |
[EN] The effects of flow variations on the galvanic corrosion of the copper/AISI 304 stainless steel pair in a concentrated lithium bromide solution were investigated in a hydraulic circuit applying different flow steps and using a zero-resistance ammeter (ZRA). The flow steps consist in applying a flow rate for sixty minutes after leaving the system under stagnant conditions for another sixty minutes; this procedure is repeated during eight hours. The magnitude of the steps is different depending on the flow regime studied, ranging from a Reynolds number of 633 to 5066. Results show that, when a flow step is applied, the galvanic current density increases and the galvanic potential shifts towards more negative values. However, with time, this increase in the galvanic current density is lower, reaching its lowest value in the last hour of the experiment at a Reynolds number of 5066. Thus, although the corrosion rate increases as Reynolds number increases, the protective corrosion products are generated earlier on the copper surface. © 2012 by ESG. |
| publishDate |
2012 |
| dc.date.none.fl_str_mv |
2012 2012-01-01 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 VoR http://purl.org/coar/version/c_970fb48d4fbd8a85 |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://riunet.upv.es/handle/10251/31148 |
| url |
https://riunet.upv.es/handle/10251/31148 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.relation.none.fl_str_mv |
Ministerio de Ciencia e Innovación http://dx.doi.org/10.13039/501100004837 CTQ2009-07518 ESTUDIO DE LA CORROSION TERMOGALVANICA EN LAS MAQUINAS DE ABSORCION DE LIBR DE DOBLE EFECTO MEDIANTE TECNICAS ELECTROQUIMICAS Y DE IMAGEN |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reserva de todos los derechos http://rightsstatements.org/vocab/InC/1.0/ |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 Reserva de todos los derechos http://rightsstatements.org/vocab/InC/1.0/ |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Electrochemical Science Group |
| publisher.none.fl_str_mv |
Electrochemical Science Group |
| dc.source.none.fl_str_mv |
reponame:RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia instname:Universitat Politècnica de València (UPV) |
| instname_str |
Universitat Politècnica de València (UPV) |