Power profile and optical performance of two extended range of vision intraocular lens designs

PURPOSE: To assess the power profile and optical performance of two extended range of vision (ERV) intraocular lenses (IOLs), TECNIS® Eyhance (ICB00) and LuxSmartTM, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS® 1-piece (ZCB00) and LuxGoodTM,...

Descripción completa

Detalles Bibliográficos
Autores: Vega Lerín, Fidel|||0000-0002-8594-0872, Garzón Jiménez, Nuria, García Montero, María, Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
Tipo de recurso: artículo
Fecha de publicación:2024
País:España
Institución:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/415599
Acceso en línea:https://hdl.handle.net/2117/415599
https://dx.doi.org/10.1097/j.jcrs.0000000000001528
Access Level:acceso abierto
Palabra clave:Intraocular lens
Extended range of vision
Power profile
Spherical aberration
Àrees temàtiques de la UPC::Ciències de la visió::Optometria
id ES_ca8ad42e5ef735f9163cf7bbbae5d786
oai_identifier_str oai:upcommons.upc.edu:2117/415599
network_acronym_str ES
network_name_str España
repository_id_str
spelling Power profile and optical performance of two extended range of vision intraocular lens designsVega Lerín, Fidel|||0000-0002-8594-0872Garzón Jiménez, NuriaGarcía Montero, MaríaMillán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373Intraocular lensExtended range of visionPower profileSpherical aberrationÀrees temàtiques de la UPC::Ciències de la visió::OptometriaPURPOSE: To assess the power profile and optical performance of two extended range of vision (ERV) intraocular lenses (IOLs), TECNIS® Eyhance (ICB00) and LuxSmartTM, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS® 1-piece (ZCB00) and LuxGoodTM, respectively. SETTING: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain. DESIGN: Laboratory investigation on optical bench METHODS: For each design, we measured the power distribution and (fourth- and sixth- order) spherical aberration (SA) across the lens aperture as well as the optical performance using modulation-transfer-function-based metrics with through-focus evaluation. Three nominal powers (+10.00, +20.00, and +30.00 D) and three pupil sizes (2.0, 3.0, and 4.5 mm) were considered to assess whether the base power of the lens and the pupillary dynamics have an influence on the depth of focus extension. RESULTS: TECNIS® Eyhance and LuxSmartTM IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmartTM had a greater add power, while TECNIS® Eyhance showed higher peak optical quality but smaller depth of focus. CONCLUSIONS: Differences of focus extension between the two ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs have little impact on their optical quality. However, the pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs.Supported by Projects PID2020-114582RB-I00/AEI/10.13039/501100011033 (FV, NG, MSM) and PID2021-122486OA-I00 (MGM, NG) from the Spanish Agencia Estatal de Investigación.Peer ReviewedObjectius de Desenvolupament Sostenible::3 - Salut i BenestarObjectius de Desenvolupament Sostenible::9 - Indústria, Innovació i Infraestructura20242024-10-0120242024-10-09journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/415599https://dx.doi.org/10.1097/j.jcrs.0000000000001528reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)InglésengAgencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-114582RB-I00 IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADAopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/4155992026-05-27T15:37:01Z
dc.title.none.fl_str_mv Power profile and optical performance of two extended range of vision intraocular lens designs
title Power profile and optical performance of two extended range of vision intraocular lens designs
spellingShingle Power profile and optical performance of two extended range of vision intraocular lens designs
Vega Lerín, Fidel|||0000-0002-8594-0872
Intraocular lens
Extended range of vision
Power profile
Spherical aberration
Àrees temàtiques de la UPC::Ciències de la visió::Optometria
title_short Power profile and optical performance of two extended range of vision intraocular lens designs
title_full Power profile and optical performance of two extended range of vision intraocular lens designs
title_fullStr Power profile and optical performance of two extended range of vision intraocular lens designs
title_full_unstemmed Power profile and optical performance of two extended range of vision intraocular lens designs
title_sort Power profile and optical performance of two extended range of vision intraocular lens designs
dc.creator.none.fl_str_mv Vega Lerín, Fidel|||0000-0002-8594-0872
Garzón Jiménez, Nuria
García Montero, María
Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
author Vega Lerín, Fidel|||0000-0002-8594-0872
author_facet Vega Lerín, Fidel|||0000-0002-8594-0872
Garzón Jiménez, Nuria
García Montero, María
Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
author_role author
author2 Garzón Jiménez, Nuria
García Montero, María
Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373
author2_role author
author
author
dc.subject.none.fl_str_mv Intraocular lens
Extended range of vision
Power profile
Spherical aberration
Àrees temàtiques de la UPC::Ciències de la visió::Optometria
topic Intraocular lens
Extended range of vision
Power profile
Spherical aberration
Àrees temàtiques de la UPC::Ciències de la visió::Optometria
description PURPOSE: To assess the power profile and optical performance of two extended range of vision (ERV) intraocular lenses (IOLs), TECNIS® Eyhance (ICB00) and LuxSmartTM, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS® 1-piece (ZCB00) and LuxGoodTM, respectively. SETTING: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain. DESIGN: Laboratory investigation on optical bench METHODS: For each design, we measured the power distribution and (fourth- and sixth- order) spherical aberration (SA) across the lens aperture as well as the optical performance using modulation-transfer-function-based metrics with through-focus evaluation. Three nominal powers (+10.00, +20.00, and +30.00 D) and three pupil sizes (2.0, 3.0, and 4.5 mm) were considered to assess whether the base power of the lens and the pupillary dynamics have an influence on the depth of focus extension. RESULTS: TECNIS® Eyhance and LuxSmartTM IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmartTM had a greater add power, while TECNIS® Eyhance showed higher peak optical quality but smaller depth of focus. CONCLUSIONS: Differences of focus extension between the two ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs have little impact on their optical quality. However, the pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs.
publishDate 2024
dc.date.none.fl_str_mv 2024
2024-10-01
2024
2024-10-09
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
AM
http://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/2117/415599
https://dx.doi.org/10.1097/j.jcrs.0000000000001528
url https://hdl.handle.net/2117/415599
https://dx.doi.org/10.1097/j.jcrs.0000000000001528
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.relation.none.fl_str_mv Agencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-114582RB-I00 IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADA
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:UPCommons. Portal del coneixement obert de la UPC
instname:Universitat Politècnica de Catalunya (UPC)
instname_str Universitat Politècnica de Catalunya (UPC)
reponame_str UPCommons. Portal del coneixement obert de la UPC
collection UPCommons. Portal del coneixement obert de la UPC
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869419488852574208
score 15,811543