Power profile and optical performance of two extended range of vision intraocular lens designs
PURPOSE: To assess the power profile and optical performance of two extended range of vision (ERV) intraocular lenses (IOLs), TECNIS® Eyhance (ICB00) and LuxSmartTM, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS® 1-piece (ZCB00) and LuxGoodTM,...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2024 |
| País: | España |
| Institución: | Universitat Politècnica de Catalunya (UPC) |
| Repositorio: | UPCommons. Portal del coneixement obert de la UPC |
| Idioma: | inglés |
| OAI Identifier: | oai:upcommons.upc.edu:2117/415599 |
| Acceso en línea: | https://hdl.handle.net/2117/415599 https://dx.doi.org/10.1097/j.jcrs.0000000000001528 |
| Access Level: | acceso abierto |
| Palabra clave: | Intraocular lens Extended range of vision Power profile Spherical aberration Àrees temàtiques de la UPC::Ciències de la visió::Optometria |
| id |
ES_ca8ad42e5ef735f9163cf7bbbae5d786 |
|---|---|
| oai_identifier_str |
oai:upcommons.upc.edu:2117/415599 |
| network_acronym_str |
ES |
| network_name_str |
España |
| repository_id_str |
|
| spelling |
Power profile and optical performance of two extended range of vision intraocular lens designsVega Lerín, Fidel|||0000-0002-8594-0872Garzón Jiménez, NuriaGarcía Montero, MaríaMillán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373Intraocular lensExtended range of visionPower profileSpherical aberrationÀrees temàtiques de la UPC::Ciències de la visió::OptometriaPURPOSE: To assess the power profile and optical performance of two extended range of vision (ERV) intraocular lenses (IOLs), TECNIS® Eyhance (ICB00) and LuxSmartTM, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS® 1-piece (ZCB00) and LuxGoodTM, respectively. SETTING: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain. DESIGN: Laboratory investigation on optical bench METHODS: For each design, we measured the power distribution and (fourth- and sixth- order) spherical aberration (SA) across the lens aperture as well as the optical performance using modulation-transfer-function-based metrics with through-focus evaluation. Three nominal powers (+10.00, +20.00, and +30.00 D) and three pupil sizes (2.0, 3.0, and 4.5 mm) were considered to assess whether the base power of the lens and the pupillary dynamics have an influence on the depth of focus extension. RESULTS: TECNIS® Eyhance and LuxSmartTM IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmartTM had a greater add power, while TECNIS® Eyhance showed higher peak optical quality but smaller depth of focus. CONCLUSIONS: Differences of focus extension between the two ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs have little impact on their optical quality. However, the pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs.Supported by Projects PID2020-114582RB-I00/AEI/10.13039/501100011033 (FV, NG, MSM) and PID2021-122486OA-I00 (MGM, NG) from the Spanish Agencia Estatal de Investigación.Peer ReviewedObjectius de Desenvolupament Sostenible::3 - Salut i BenestarObjectius de Desenvolupament Sostenible::9 - Indústria, Innovació i Infraestructura20242024-10-0120242024-10-09journal articlehttp://purl.org/coar/resource_type/c_6501AMhttp://purl.org/coar/version/c_ab4af688f83e57aainfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/2117/415599https://dx.doi.org/10.1097/j.jcrs.0000000000001528reponame:UPCommons. Portal del coneixement obert de la UPCinstname:Universitat Politècnica de Catalunya (UPC)InglésengAgencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-114582RB-I00 IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADAopen accesshttp://purl.org/coar/access_right/c_abf2info:eu-repo/semantics/openAccessoai:upcommons.upc.edu:2117/4155992026-05-27T15:37:01Z |
| dc.title.none.fl_str_mv |
Power profile and optical performance of two extended range of vision intraocular lens designs |
| title |
Power profile and optical performance of two extended range of vision intraocular lens designs |
| spellingShingle |
Power profile and optical performance of two extended range of vision intraocular lens designs Vega Lerín, Fidel|||0000-0002-8594-0872 Intraocular lens Extended range of vision Power profile Spherical aberration Àrees temàtiques de la UPC::Ciències de la visió::Optometria |
| title_short |
Power profile and optical performance of two extended range of vision intraocular lens designs |
| title_full |
Power profile and optical performance of two extended range of vision intraocular lens designs |
| title_fullStr |
Power profile and optical performance of two extended range of vision intraocular lens designs |
| title_full_unstemmed |
Power profile and optical performance of two extended range of vision intraocular lens designs |
| title_sort |
Power profile and optical performance of two extended range of vision intraocular lens designs |
| dc.creator.none.fl_str_mv |
Vega Lerín, Fidel|||0000-0002-8594-0872 Garzón Jiménez, Nuria García Montero, María Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 |
| author |
Vega Lerín, Fidel|||0000-0002-8594-0872 |
| author_facet |
Vega Lerín, Fidel|||0000-0002-8594-0872 Garzón Jiménez, Nuria García Montero, María Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 |
| author_role |
author |
| author2 |
Garzón Jiménez, Nuria García Montero, María Millán Garcia-Varela, M. Sagrario|||0000-0001-6950-2373 |
| author2_role |
author author author |
| dc.subject.none.fl_str_mv |
Intraocular lens Extended range of vision Power profile Spherical aberration Àrees temàtiques de la UPC::Ciències de la visió::Optometria |
| topic |
Intraocular lens Extended range of vision Power profile Spherical aberration Àrees temàtiques de la UPC::Ciències de la visió::Optometria |
| description |
PURPOSE: To assess the power profile and optical performance of two extended range of vision (ERV) intraocular lenses (IOLs), TECNIS® Eyhance (ICB00) and LuxSmartTM, and compare them with their monofocal counterpart lenses with similar platforms and materials: TECNIS® 1-piece (ZCB00) and LuxGoodTM, respectively. SETTING: Optics and Optometry Faculties of Complutense University (Madrid) and Universitat Politècnica de Catalunya BarcelonaTech (Terrassa) in Spain. DESIGN: Laboratory investigation on optical bench METHODS: For each design, we measured the power distribution and (fourth- and sixth- order) spherical aberration (SA) across the lens aperture as well as the optical performance using modulation-transfer-function-based metrics with through-focus evaluation. Three nominal powers (+10.00, +20.00, and +30.00 D) and three pupil sizes (2.0, 3.0, and 4.5 mm) were considered to assess whether the base power of the lens and the pupillary dynamics have an influence on the depth of focus extension. RESULTS: TECNIS® Eyhance and LuxSmartTM IOLs had different power and SA profiles, but both designs shared a positive add power in their central region in comparison with their monofocal counterparts. LuxSmartTM had a greater add power, while TECNIS® Eyhance showed higher peak optical quality but smaller depth of focus. CONCLUSIONS: Differences of focus extension between the two ERV IOL designs are related to differences of power and SA profile. The nominal base power of the IOLs have little impact on their optical quality. However, the pupil dynamics plays a key role since it determines the effective add power and optical performance of the ERV IOLs. |
| publishDate |
2024 |
| dc.date.none.fl_str_mv |
2024 2024-10-01 2024 2024-10-09 |
| dc.type.none.fl_str_mv |
journal article http://purl.org/coar/resource_type/c_6501 AM http://purl.org/coar/version/c_ab4af688f83e57aa |
| dc.type.openaire.fl_str_mv |
info:eu-repo/semantics/article |
| format |
article |
| dc.identifier.none.fl_str_mv |
https://hdl.handle.net/2117/415599 https://dx.doi.org/10.1097/j.jcrs.0000000000001528 |
| url |
https://hdl.handle.net/2117/415599 https://dx.doi.org/10.1097/j.jcrs.0000000000001528 |
| dc.language.none.fl_str_mv |
Inglés eng |
| language_invalid_str_mv |
Inglés |
| language |
eng |
| dc.relation.none.fl_str_mv |
Agencia Estatal de Investigación http://doi.org/10.13039/501100011033 Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020 PID2020-114582RB-I00 IMPLANTES OPTICOS INTRAOCULARES CORRECTORES DE LA PRESBICIA PARA UNA COMPENSACION VISUAL PERSONALIZADA |
| dc.rights.none.fl_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| dc.rights.openaire.fl_str_mv |
info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
open access http://purl.org/coar/access_right/c_abf2 |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.source.none.fl_str_mv |
reponame:UPCommons. Portal del coneixement obert de la UPC instname:Universitat Politècnica de Catalunya (UPC) |
| instname_str |
Universitat Politècnica de Catalunya (UPC) |
| reponame_str |
UPCommons. Portal del coneixement obert de la UPC |
| collection |
UPCommons. Portal del coneixement obert de la UPC |
| repository.name.fl_str_mv |
|
| repository.mail.fl_str_mv |
|
| _version_ |
1869419488852574208 |
| score |
15,811543 |