Predictive model of clothing insulation in naturally ventilated educational buildings

Providing suitable indoor thermal conditions in educational buildings is crucial to ensuring the performance and well-being of students. International standards and building codes state that thermal conditions should be considered during the indoor design process and sizing of heating, ventilation a...

Descripción completa

Detalles Bibliográficos
Autores: Hoz Torres, María Luisa de la, Aguilar Aguilera, Antonio Jesús, Costa, Nélson, Arezes, Pedro, Ruiz Padillo, Diego Pablo, Martínez Aires, María Dolores
Tipo de recurso: artículo
Estado:Versión publicada
Fecha de publicación:2023
País:España
Institución:Universidad de Sevilla (US)
Repositorio:idUS. Depósito de Investigación de la Universidad de Sevilla
OAI Identifier:oai:idus.us.es:11441/160601
Acceso en línea:https://hdl.handle.net/11441/160601
https://doi.org/10.3390/buildings13041002
Access Level:acceso abierto
Palabra clave:Built environment
Educational buildings
Thermal environment
Clothing insulation
Occupant behaviour
Natural ventilation
Descripción
Sumario:Providing suitable indoor thermal conditions in educational buildings is crucial to ensuring the performance and well-being of students. International standards and building codes state that thermal conditions should be considered during the indoor design process and sizing of heating, ventilation and air conditioning systems. Clothing insulation is one of the main factors influencing the occupants’ thermal perception. In this context, a field survey was conducted in higher education buildings to analyse and evaluate the clothing insulation of university students. The results showed that the mean clothing insulation values were 0.60 clo and 0.72 clo for male and female students, respectively. Significant differences were found between seasons. Correlations were found between indoor and outdoor air temperature, radiant temperature, the temperature measured at 6 a.m., and running mean temperature. Based on the collected data, a predictive clothing insulation model, based on an artificial neural network (ANN) algorithm, was developed using indoor and outdoor air temperature, radiant temperature, the temperature measured at 6 a.m. and running mean temperature, gender, and season as input parameters. The ANN model showed a performance of R2 = 0.60 and r = 0.80. Fifty percent of the predicted values differed by less than 0.1 clo from the actual value, whereas this percentage only amounted to 32% if the model defined in the ASHRAE-55 Standard was applied.