Evaluation of two rapid ultrafiltration-based methods for SARS-CoV-2 concentration from wastewater

Quantitative measurements of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in rawwastewater have been implemented worldwide since the beginning of the pandemic. Recent efforts are being made to evaluate different viral concentration methodologies to overcome supplier shortages dur...

Descripción completa

Detalles Bibliográficos
Autores: Fores i Planells, Elisenda, Bofill Mas, Silvia, Itarte, Marta, Martínez-Puchol, Sandra, Hundesa Gonfa, Ayalkibet, Calvo, Miquel (Calvo Llorca), Borrego, C.M., Corominas, L.L., Gironès Llop, Rosina, Rusiñol Arantegui, Marta
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2021
País:España
Institución:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:2445/195858
Acceso en línea:https://hdl.handle.net/2445/195858
Access Level:acceso abierto
Palabra clave:SARS-CoV-2
Ultrafiltració
Ultrafiltration
Descripción
Sumario:Quantitative measurements of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in rawwastewater have been implemented worldwide since the beginning of the pandemic. Recent efforts are being made to evaluate different viral concentration methodologies to overcome supplier shortages during lockdowns. A set of 22-wastewater samples seeded with murine hepatitis virus (MHV), a member of the Coronaviridae family, and the bacteriophage MS2, were used to characterize and compare two ultrafiltration-based methods: a centrifugal ultrafiltration device (Centricon® Plus-70) and the automated concentrating pipette CP-Select¿. Based on the recovery efficiencies, significant differences were observed for MHV, with Centricon® Plus-70 (24%) being the most efficient method. Nevertheless, concentrations of naturally occurring SARS-CoV-2, Human adenoviruses and JC polyomaviruses in these samples did not result in significant differences between methods suggesting that testing naturally occurring viruses may complement the evaluation of viral concentration methodologies. Based on the virus adsorption to solids and the necessity of a pre-centrifugation step to remove larger particles and avoid clogging when using ultrafiltration methods, we assessed the percentage of viruses not quantified after ultrafiltration. Around 23% of the detected SARS-CoV-2 would be discarded during the debris removal step. The CP-Select¿ provided the highest concentration factor (up to 333×) and the lowest LoD (6.19 × 103 GC/l) forMHV and proved to be fast, automatic, highly reproducible and suitable to work under BSL-2 measures.