Effect of a recent intradermal test on the specificity of P22 ELISA for the diagnosis of caprine tuberculosis
Caprine tuberculosis (TB) is a zoonotic disease caused by members of the Mycobacterium tuberculosis complex. TB eradication programs in goats are based on the single and comparative intradermal tuberculin tests (SITT and CITT, respectively). Antibody-based diagnostic techniques have emerged as poten...
| Autores: | , , , , , , , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2024 |
| País: | España |
| Institución: | Universidad Complutense de Madrid (UCM) |
| Repositorio: | Docta Complutense |
| Idioma: | inglés |
| OAI Identifier: | oai:docta.ucm.es:20.500.14352/101909 |
| Acceso en línea: | https://hdl.handle.net/20.500.14352/101909 |
| Access Level: | acceso abierto |
| Palabra clave: | 636.09 Caprine tuberculosis Intradermal tuberculin test P22 ELISA Booster effect Specificity Veterinaria 3109 Ciencias Veterinarias |
| Sumario: | Caprine tuberculosis (TB) is a zoonotic disease caused by members of the Mycobacterium tuberculosis complex. TB eradication programs in goats are based on the single and comparative intradermal tuberculin tests (SITT and CITT, respectively). Antibody-based diagnostic techniques have emerged as potential diagnostic tools for TB. P22 ELISA has been previously evaluated using samples collected after the intradermal tuberculin tests to maximize the sensitivity, a phenomenon known as booster effect. However, there is no information available on whether the use of this diagnostic strategy could lead to a decrease of its specificity (Sp). The aim of the present study was to elucidate the interference effect of a recent CITT on the Sp of the P22 ELISA in serum and milk samples collected at different times after the CITT from a TB-free herd (n = 113). The number of reactors to P22 ELISA was significantly higher (p < 0.01) on serum samples collected 15 days post-CITT compared to day 0, showing a decrease in Sp from 99.1% (95% CI; 95.2–99.8%) to 88.5% (95% CI; 81.3–93.2%). The number of reactors and the quantitative values of P22 ELISA were significantly higher (p < 0.01) in serum samples compared to milk. No significant (p > 0.05) changes in the Sp of the P22 ELISA were observed throughout the different time samplings using milk No significant (p > 0.05) changes were observed on days 30 and 60 post-CITT. In conclusion, the booster effect strategy may significantly decrease the Sp of P22 ELISA in TB-free herds when serum samples are used but not when milk is tested. |
|---|