Evaluation of Alternatives for Energy Supply from fuel Cells in Compact Cities in the Mediterranean Climate. Case Study: City of Valencia
[EN] A study of energy supply alternatives was carried out based on a cogeneration fuel cell system fed from the natural gas network of compact Mediterranean cities. As a case study it was applied to the residential energy demands of the L'Illa Perduda neighbourhood, located in the east of...
| Autores: | , , , |
|---|---|
| Tipo de recurso: | artículo |
| Fecha de publicación: | 2022 |
| País: | España |
| Institución: | Universitat Politècnica de València (UPV) |
| Repositorio: | RiuNet. Repositorio Institucional de la Universitat Politécnica de Valéncia |
| Idioma: | inglés |
| OAI Identifier: | oai:riunet.upv.es:10251/193391 |
| Acceso en línea: | https://riunet.upv.es/handle/10251/193391 |
| Access Level: | acceso abierto |
| Palabra clave: | Fuel cells Hydrogen Energy communities TECNOLOGIA ELECTRONICA MAQUINAS Y MOTORES TERMICOS PROYECTOS DE INGENIERIA 07.- Asegurar el acceso a energías asequibles, fiables, sostenibles y modernas para todos 11.- Conseguir que las ciudades y los asentamientos humanos sean inclusivos, seguros, resilientes y sostenibles 13.- Tomar medidas urgentes para combatir el cambio climático y sus efectos |
| Sumario: | [EN] A study of energy supply alternatives was carried out based on a cogeneration fuel cell system fed from the natural gas network of compact Mediterranean cities. As a case study it was applied to the residential energy demands of the L'Illa Perduda neighbourhood, located in the east of the city of Valencia and consisting of 4194 residential cells. In total, eight different alternatives were studied according to the load curve, the power of the system, the mode of operation and the distribution of the fuel cells. In this way, the advantages and disadvantages of each configuration were found. This information, together with the previous study of the energy characteristics of the neighbourhood, enabled selection of the most promising configuration and to decide whether or not to recommend investment. The chosen configuration was a centralised system of phosphoric acid fuel cells in cogeneration, with approximately 4 MW of thermal power and an operating mode that varied according to the outside temperature. In this way, when heating is required, the plant adjusts its production to the thermal demand, and when cooling is required, the plant follows the electrical demand. This configuration presented the best energy results, as it achieved good coverage of thermal (62.5%) and electrical (88.1%) demands with good primary energy savings (28.36 GWh/year). However, due to the high power of the system and low maturity (i.e., high costs) of this technology, would be necessary to make a large initial economic investment of 15.2 Meuro. |
|---|