Accuracy of freehand versus dynamic computer-assisted zygomatic implant placement: An in-vitro study

Objective: To compare the accuracy of zygomatic implant placement using a dynamic computer-assisted implant surgery system (D-CAIS) versus the traditional freehand approach. Methods: An experimental in vitro study was conducted using 10 stereolithographic models randomized to two groups: D-CAIS (tes...

ver descrição completa

Detalhes bibliográficos
Autores: Traboulsi Garet, Bassel, Jorba García, Adrià, Bara Casaus, Javier, Camps Font, Octavi, Valmaseda Castellón, Eduardo, Barbosa de Figueiredo, Rui Pedro, Sánchez Garcés, Ma. Ángeles
Formato: artículo
Estado:Versión publicada
Fecha de publicación:2025
País:España
Recursos:Varias* (Consorci de Biblioteques Universitáries de Catalunya, Centre de Serveis Científics i Acadèmics de Catalunya)
Repositorio:Recercat. Dipósit de la Recerca de Catalunya
OAI Identifier:oai:recercat.cat:2445/221513
Acesso em linha:https://hdl.handle.net/2445/221513
Access Level:acceso abierto
Palavra-chave:Diagnòstic per la imatge
Cirurgia dental
Implants dentals
Ordinadors
Diagnostic imaging
Dental surgery
Dental implants
Computers
Descrição
Resumo:Objective: To compare the accuracy of zygomatic implant placement using a dynamic computer-assisted implant surgery system (D-CAIS) versus the traditional freehand approach. Methods: An experimental in vitro study was conducted using 10 stereolithographic models randomized to two groups: D-CAIS (test group) and freehand placement (control group). A single zygomatic implant was placed on each side of the models. The accuracy of implant placement was assessed by superimposing the actual postoperative implant position, obtained via cone-beam computed tomography (CBCT), with the virtual preoperative surgical plan from the preoperative CBCT. Additionally, the operated side and surgery duration were recorded. Descriptive statistics and bivariate analyses were performed to evaluate the data. Results: The D-CAIS group demonstrated significantly greater accuracy across most outcome variables. Reductions in angular (MD = -5.33°; 95 %CI: -7.37 to -3.29; p < 0.001), coronal global (MD = -2.26 mm; 95 %CI: -2.97 to -1.55; p < 0.001), coronal horizontal 2D (MD = -1.96 mm; 95 %CI: -2.60 to -1.32; p < 0.001) and apical global deviations (MD = -3.37 mm; 95 %CI: -4.36 to -2.38; p < 0.001) were observed. Accuracy in the freehand group varied significantly between operated sides. However, the surgical procedures in the D-CAIS group were significantly longer (MD = 11.90 mins; 95 %CI: 9.37 to 14.44; p < 0.001). Conclusions: D-CAIS navigation systems offer significantly greater accuracy in zygomatic implant placement compared to the traditional freehand technique. Additionally, D-CAIS systems may minimize discrepancies in accuracy between operated sides, though their use is associated with an increase in the duration of surgery. Clinical significance: D-CAIS navigation systems improve the accuracy of zygomatic implant placement. However, an increase in the duration of surgery is to be expected.