Laboratory and in-situ mechanical characterisation of masonry components by comparing destructive and minor destructive testing techniques

The safeguard of existing masonry buildings requires a meticulous characterisation of the component materials (units and mortar) by using in-situ minimally intrusive techniques. This need is especially prominent in the case of heritage buildings in order to minimize their damage and alteration. This...

ver descrição completa

Detalhes bibliográficos
Autores: Cabané Cañas, Albert|||0000-0002-5858-2563, Pelà, Luca|||0000-0001-7760-8290, Roca Fabregat, Pedro|||0000-0001-5400-5817
Formato: artículo
Fecha de publicación:2023
País:España
Recursos:Universitat Politècnica de Catalunya (UPC)
Repositorio:UPCommons. Portal del coneixement obert de la UPC
Idioma:inglés
OAI Identifier:oai:upcommons.upc.edu:2117/401001
Acesso em linha:https://hdl.handle.net/2117/401001
https://dx.doi.org/10.1016/j.conbuildmat.2023.134474
Access Level:acceso abierto
Palavra-chave:Masonry -- Testing
Historic buildings
Strength of materials
Masonry
Minor Destructive Testing (MDT)
Double Punch Test (DPT)
Helix screw Pull-out Test (HPT)
Pin Penetration Test (PPT)
Solid fired clay bricks
Mortar joints
Compressive strength
Handmade bricks
Historical buildings
Ram de paleta
Tancaments (Construcció)
Edificis històrics
Àrees temàtiques de la UPC::Enginyeria civil::Materials i estructures
Descrição
Resumo:The safeguard of existing masonry buildings requires a meticulous characterisation of the component materials (units and mortar) by using in-situ minimally intrusive techniques. This need is especially prominent in the case of heritage buildings in order to minimize their damage and alteration. This paper presents a research on some minor destructive techniques (MDT) for the in-situ evaluation of the mechanical properties of masonry components. In the research, the results derived from MDT were empirically correlated with the compressive strength obtained by using well-known destructive testing (DT) techniques executed in the laboratory. The experimental campaign focused on two different MDT techniques, namely the Pin Penetration Test (PPT) and the Helix screw Pull-out Test (HPT). The PPT is based on the measurement of the depth of penetration of a steel pin. The HPT is based on the measurement of the pull-out load necessary to extract a steel tie inserted into a hole drilled in a brick or in a mortar joint. The experimental campaign also included an evaluation of the Double Punch Test (DPT) by comparison with strength values obtained from mortar specimens prepared and tested following the standard EN 1015–11. The experimental results show a satisfactory agreement between the MDT measurements and the compressive strength obtained with DT. Although both the PPT and HPT are useful for the evaluation of the compressive strength of masonry components, the former exhibits a lower scattering in the experimental measurements.