CGE-laser induced fluorescence of double-stranded DNA fragments using GelGreen dye

Nowadays, new solutions focused on the replacement of reagents hazardous to human health are highly demanded in laboratories and Green Chemistry. In the present work, GelGreen, a new nonhazardous DNA staining reagent, has been assayed for the first time to analyze double-stranded DNA by CGE with LIF...

Descripción completa

Detalles Bibliográficos
Autores: Valdés, Alberto, García-Cañas, Virginia, Cifuentes, Alejandro
Tipo de recurso: artículo
Estado:Versión aceptada para publicación
Fecha de publicación:2013
País:España
Institución:Consejo Superior de Investigaciones Científicas (CSIC)
Repositorio:DIGITAL.CSIC. Repositorio Institucional del CSIC
OAI Identifier:oai:digital.csic.es:10261/99861
Acceso en línea:http://hdl.handle.net/10261/99861
Access Level:acceso abierto
Palabra clave:DNA separation
Fluorescent DNA-staining dye
GelGreen
PCR
CGE-LIF
Descripción
Sumario:Nowadays, new solutions focused on the replacement of reagents hazardous to human health are highly demanded in laboratories and Green Chemistry. In the present work, GelGreen, a new nonhazardous DNA staining reagent, has been assayed for the first time to analyze double-stranded DNA by CGE with LIF detection. The effect of GelGreen concentration on S/N ratio and migration time of a wide concentration range of standard DNA mixtures was evaluated. Under optimum GelGreen concentration in the sieving buffer efficient and sensitive separations of DNA fragments with sizes from 100-500 base pairs (bp) were obtained. A comparison in terms of resolution, time of analysis, LOD, LOQ, reproducibility, sizing performance, and cost of analysis was established between two optimized CGE-LIF protocols for DNA analysis, one based on the dye YOPRO-1 (typically used for CGE-LIF of DNA fragments) and another one using the new GelGreen. Analyses using YOPRO-1 were faster than those using GelGreen (ca. 31 min versus 34 min for the analysis of 100-500 bp DNA fragments). On the other side, sensitivity using GelGreen was twofold higher than that using YOPRO-1. The cost of analysis was significantly cheaper (ninefold) using GelGreen than with YOPRO-1. The resolution values and sizing performance were not significantly different between the two dyes (e.g. both dyes allowed the separation of fragments differing in only 2 bp in the 100-200 bp range). The usefulness of the separation method using GelGreen is demonstrated by the characterization of different amplicons obtained by PCR.