Squareness error calibration of a CMM for quality control of ophthalmic lenses

This paper proposes a calibration procedure for the squareness error of small-sized coordinate measuring machines like those used for ophthalmic lenses quality control. The proposed procedure only requires a spherical lens as a reference surface and it only needs to be measured once making this cali...

Descripción completa

Detalles Bibliográficos
Autores: Quiroga Mellado, Juan Antonio, Rodríguez Ibáñez, Diego, Alonso Fernández, José
Tipo de recurso: artículo
Fecha de publicación:2013
País:España
Institución:Universidad Complutense de Madrid (UCM)
Repositorio:Docta Complutense
Idioma:inglés
OAI Identifier:oai:docta.ucm.es:20.500.14352/33371
Acceso en línea:https://hdl.handle.net/20.500.14352/33371
Access Level:acceso abierto
Palabra clave:535
CMM
Calibration
Squareness Error
Volumetric Error
Ophthalmic Lenses Quality Control
Óptica (Física)
2209.19 Óptica Física
id ES_c0b06bc8f24895c278d02dcb7e1cd1be
oai_identifier_str oai:docta.ucm.es:20.500.14352/33371
network_acronym_str ES
network_name_str España
repository_id_str
spelling Squareness error calibration of a CMM for quality control of ophthalmic lensesQuiroga Mellado, Juan AntonioRodríguez Ibáñez, DiegoAlonso Fernández, José535CMMCalibrationSquareness ErrorVolumetric ErrorOphthalmic Lenses Quality ControlÓptica (Física)2209.19 Óptica FísicaThis paper proposes a calibration procedure for the squareness error of small-sized coordinate measuring machines like those used for ophthalmic lenses quality control. The proposed procedure only requires a spherical lens as a reference surface and it only needs to be measured once making this calibration method faster and cheaper than the existing ones.Springer London Ltd.Universidad Complutense de Madrid20132013-09-0120132013-09-01journal articlehttp://purl.org/coar/resource_type/c_6501info:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/20.500.14352/33371reponame:Docta Complutenseinstname:Universidad Complutense de Madrid (UCM)Inglésengopen accesshttp://purl.org/coar/access_right/c_abf2Atribución 3.0 Españahttps://creativecommons.org/licenses/by/3.0/es/info:eu-repo/semantics/openAccessoai:docta.ucm.es:20.500.14352/333712026-06-02T12:44:21Z
dc.title.none.fl_str_mv Squareness error calibration of a CMM for quality control of ophthalmic lenses
title Squareness error calibration of a CMM for quality control of ophthalmic lenses
spellingShingle Squareness error calibration of a CMM for quality control of ophthalmic lenses
Quiroga Mellado, Juan Antonio
535
CMM
Calibration
Squareness Error
Volumetric Error
Ophthalmic Lenses Quality Control
Óptica (Física)
2209.19 Óptica Física
title_short Squareness error calibration of a CMM for quality control of ophthalmic lenses
title_full Squareness error calibration of a CMM for quality control of ophthalmic lenses
title_fullStr Squareness error calibration of a CMM for quality control of ophthalmic lenses
title_full_unstemmed Squareness error calibration of a CMM for quality control of ophthalmic lenses
title_sort Squareness error calibration of a CMM for quality control of ophthalmic lenses
dc.creator.none.fl_str_mv Quiroga Mellado, Juan Antonio
Rodríguez Ibáñez, Diego
Alonso Fernández, José
author Quiroga Mellado, Juan Antonio
author_facet Quiroga Mellado, Juan Antonio
Rodríguez Ibáñez, Diego
Alonso Fernández, José
author_role author
author2 Rodríguez Ibáñez, Diego
Alonso Fernández, José
author2_role author
author
dc.contributor.none.fl_str_mv Universidad Complutense de Madrid
dc.subject.none.fl_str_mv 535
CMM
Calibration
Squareness Error
Volumetric Error
Ophthalmic Lenses Quality Control
Óptica (Física)
2209.19 Óptica Física
topic 535
CMM
Calibration
Squareness Error
Volumetric Error
Ophthalmic Lenses Quality Control
Óptica (Física)
2209.19 Óptica Física
description This paper proposes a calibration procedure for the squareness error of small-sized coordinate measuring machines like those used for ophthalmic lenses quality control. The proposed procedure only requires a spherical lens as a reference surface and it only needs to be measured once making this calibration method faster and cheaper than the existing ones.
publishDate 2013
dc.date.none.fl_str_mv 2013
2013-09-01
2013
2013-09-01
dc.type.none.fl_str_mv journal article
http://purl.org/coar/resource_type/c_6501
dc.type.openaire.fl_str_mv info:eu-repo/semantics/article
format article
dc.identifier.none.fl_str_mv https://hdl.handle.net/20.500.14352/33371
url https://hdl.handle.net/20.500.14352/33371
dc.language.none.fl_str_mv Inglés
eng
language_invalid_str_mv Inglés
language eng
dc.rights.none.fl_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 3.0 España
https://creativecommons.org/licenses/by/3.0/es/
dc.rights.openaire.fl_str_mv info:eu-repo/semantics/openAccess
rights_invalid_str_mv open access
http://purl.org/coar/access_right/c_abf2
Atribución 3.0 España
https://creativecommons.org/licenses/by/3.0/es/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Springer London Ltd.
publisher.none.fl_str_mv Springer London Ltd.
dc.source.none.fl_str_mv reponame:Docta Complutense
instname:Universidad Complutense de Madrid (UCM)
instname_str Universidad Complutense de Madrid (UCM)
reponame_str Docta Complutense
collection Docta Complutense
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1869418498681208832
score 15.301629